Cargando…
Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-mo...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4754375/ https://www.ncbi.nlm.nih.gov/pubmed/26925130 http://dx.doi.org/10.5114/aoms.2016.57590 |
_version_ | 1782416004040622080 |
---|---|
author | Utzschneider, Sandra Chita, Claudia Paulus, Alexander C. Guenther, Christian Jansson, Volkmar Heimkes, Bernhard |
author_facet | Utzschneider, Sandra Chita, Claudia Paulus, Alexander C. Guenther, Christian Jansson, Volkmar Heimkes, Bernhard |
author_sort | Utzschneider, Sandra |
collection | PubMed |
description | INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-monitored treated hips (initial staging according to Graf: type IIc–IV) which attained normal ultrasound findings (type I according to Graf) during treatment and underwent an anteroposterior radiograph of the pelvis at the time of starting walking (mean age 18.6 months) were evaluated retrospectively. RESULTS: While all hips showed normal sonographic values (Graf type I), 26 (17%) showed mild and 17 (11.1%) severe dysplasia (by measuring the acetabular index) according to the radiographic Toennis classification system, and 29 (19%) showed mild and 48 (31.4%) severe dysplasia according to the Wiberg centre-edge angle. CONCLUSIONS: This data show that the actually used sonographic and radiographic standard values concerning DDH do not correlate appropriately. It must be put up for discussion whether the radiographic standard values might be too strict. Further criteria must be developed to better assess the prognosis of residual dysplasia. |
format | Online Article Text |
id | pubmed-4754375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-47543752016-02-26 Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip Utzschneider, Sandra Chita, Claudia Paulus, Alexander C. Guenther, Christian Jansson, Volkmar Heimkes, Bernhard Arch Med Sci Clinical Research INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-monitored treated hips (initial staging according to Graf: type IIc–IV) which attained normal ultrasound findings (type I according to Graf) during treatment and underwent an anteroposterior radiograph of the pelvis at the time of starting walking (mean age 18.6 months) were evaluated retrospectively. RESULTS: While all hips showed normal sonographic values (Graf type I), 26 (17%) showed mild and 17 (11.1%) severe dysplasia (by measuring the acetabular index) according to the radiographic Toennis classification system, and 29 (19%) showed mild and 48 (31.4%) severe dysplasia according to the Wiberg centre-edge angle. CONCLUSIONS: This data show that the actually used sonographic and radiographic standard values concerning DDH do not correlate appropriately. It must be put up for discussion whether the radiographic standard values might be too strict. Further criteria must be developed to better assess the prognosis of residual dysplasia. Termedia Publishing House 2016-02-02 2016-02-01 /pmc/articles/PMC4754375/ /pubmed/26925130 http://dx.doi.org/10.5114/aoms.2016.57590 Text en Copyright © 2016 Termedia & Banach http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Clinical Research Utzschneider, Sandra Chita, Claudia Paulus, Alexander C. Guenther, Christian Jansson, Volkmar Heimkes, Bernhard Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title | Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title_full | Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title_fullStr | Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title_full_unstemmed | Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title_short | Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
title_sort | discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4754375/ https://www.ncbi.nlm.nih.gov/pubmed/26925130 http://dx.doi.org/10.5114/aoms.2016.57590 |
work_keys_str_mv | AT utzschneidersandra discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip AT chitaclaudia discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip AT paulusalexanderc discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip AT guentherchristian discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip AT janssonvolkmar discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip AT heimkesbernhard discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip |