Cargando…

Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip

INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-mo...

Descripción completa

Detalles Bibliográficos
Autores principales: Utzschneider, Sandra, Chita, Claudia, Paulus, Alexander C., Guenther, Christian, Jansson, Volkmar, Heimkes, Bernhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4754375/
https://www.ncbi.nlm.nih.gov/pubmed/26925130
http://dx.doi.org/10.5114/aoms.2016.57590
_version_ 1782416004040622080
author Utzschneider, Sandra
Chita, Claudia
Paulus, Alexander C.
Guenther, Christian
Jansson, Volkmar
Heimkes, Bernhard
author_facet Utzschneider, Sandra
Chita, Claudia
Paulus, Alexander C.
Guenther, Christian
Jansson, Volkmar
Heimkes, Bernhard
author_sort Utzschneider, Sandra
collection PubMed
description INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-monitored treated hips (initial staging according to Graf: type IIc–IV) which attained normal ultrasound findings (type I according to Graf) during treatment and underwent an anteroposterior radiograph of the pelvis at the time of starting walking (mean age 18.6 months) were evaluated retrospectively. RESULTS: While all hips showed normal sonographic values (Graf type I), 26 (17%) showed mild and 17 (11.1%) severe dysplasia (by measuring the acetabular index) according to the radiographic Toennis classification system, and 29 (19%) showed mild and 48 (31.4%) severe dysplasia according to the Wiberg centre-edge angle. CONCLUSIONS: This data show that the actually used sonographic and radiographic standard values concerning DDH do not correlate appropriately. It must be put up for discussion whether the radiographic standard values might be too strict. Further criteria must be developed to better assess the prognosis of residual dysplasia.
format Online
Article
Text
id pubmed-4754375
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-47543752016-02-26 Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip Utzschneider, Sandra Chita, Claudia Paulus, Alexander C. Guenther, Christian Jansson, Volkmar Heimkes, Bernhard Arch Med Sci Clinical Research INTRODUCTION: The purpose of the study was to examine the accordance between the actually used sonographic and radiographic standard values after ultrasound-monitored treatment of developmental dysplasia of the hip (DDH). MATERIAL AND METHODS: One hundred and fifty-three (119 children) ultrasound-monitored treated hips (initial staging according to Graf: type IIc–IV) which attained normal ultrasound findings (type I according to Graf) during treatment and underwent an anteroposterior radiograph of the pelvis at the time of starting walking (mean age 18.6 months) were evaluated retrospectively. RESULTS: While all hips showed normal sonographic values (Graf type I), 26 (17%) showed mild and 17 (11.1%) severe dysplasia (by measuring the acetabular index) according to the radiographic Toennis classification system, and 29 (19%) showed mild and 48 (31.4%) severe dysplasia according to the Wiberg centre-edge angle. CONCLUSIONS: This data show that the actually used sonographic and radiographic standard values concerning DDH do not correlate appropriately. It must be put up for discussion whether the radiographic standard values might be too strict. Further criteria must be developed to better assess the prognosis of residual dysplasia. Termedia Publishing House 2016-02-02 2016-02-01 /pmc/articles/PMC4754375/ /pubmed/26925130 http://dx.doi.org/10.5114/aoms.2016.57590 Text en Copyright © 2016 Termedia & Banach http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Clinical Research
Utzschneider, Sandra
Chita, Claudia
Paulus, Alexander C.
Guenther, Christian
Jansson, Volkmar
Heimkes, Bernhard
Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title_full Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title_fullStr Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title_full_unstemmed Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title_short Discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
title_sort discrepancy between sonographic and radiographic values after ultrasound-monitored treatment of developmental dysplasia of the hip
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4754375/
https://www.ncbi.nlm.nih.gov/pubmed/26925130
http://dx.doi.org/10.5114/aoms.2016.57590
work_keys_str_mv AT utzschneidersandra discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip
AT chitaclaudia discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip
AT paulusalexanderc discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip
AT guentherchristian discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip
AT janssonvolkmar discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip
AT heimkesbernhard discrepancybetweensonographicandradiographicvaluesafterultrasoundmonitoredtreatmentofdevelopmentaldysplasiaofthehip