Cargando…

Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity

PURPOSE: To study the density and packing geometry of the extrafoveal cone photoreceptors in eyes with a history of retinopathy of prematurity (ROP). We used a multimodal combination of adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). METHODS: Cones we...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramamirtham, Ramkumar, Akula, James D., Soni, Garima, Swanson, Matthew J., Bush, Jennifer N., Moskowitz, Anne, Swanson, Emily A., Favazza, Tara L., Tavormina, Jena L., Mujat, Mircea, Ferguson, R. Daniel, Hansen, Ronald M., Fulton, Anne B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4758295/
https://www.ncbi.nlm.nih.gov/pubmed/26868749
http://dx.doi.org/10.1167/iovs.15-17783
_version_ 1782416589735329792
author Ramamirtham, Ramkumar
Akula, James D.
Soni, Garima
Swanson, Matthew J.
Bush, Jennifer N.
Moskowitz, Anne
Swanson, Emily A.
Favazza, Tara L.
Tavormina, Jena L.
Mujat, Mircea
Ferguson, R. Daniel
Hansen, Ronald M.
Fulton, Anne B.
author_facet Ramamirtham, Ramkumar
Akula, James D.
Soni, Garima
Swanson, Matthew J.
Bush, Jennifer N.
Moskowitz, Anne
Swanson, Emily A.
Favazza, Tara L.
Tavormina, Jena L.
Mujat, Mircea
Ferguson, R. Daniel
Hansen, Ronald M.
Fulton, Anne B.
author_sort Ramamirtham, Ramkumar
collection PubMed
description PURPOSE: To study the density and packing geometry of the extrafoveal cone photoreceptors in eyes with a history of retinopathy of prematurity (ROP). We used a multimodal combination of adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). METHODS: Cones were identified in subjects (aged 14–26 years) with a history of ROP that was either severe and treated by laser ablation of avascular peripheral retina (TROP; n = 5) or mild and spontaneously resolved, untreated (UROP; n = 5), and in term-born controls (CT; n = 8). The AO-SLO images were obtained at temporal eccentricities 4.5°, 9°, 13.5°, and 18° using both confocal and offset apertures with simultaneous, colocal OCT images. Effects of group, eccentricity, and aperture were evaluated and the modalities compared. RESULTS: In the SLO images, cone density was lower and the packing pattern less regular in TROP, relative to CT and UROP retinae. Although SLO image quality appeared lower in TROP, root mean square (RMS) wavefront error did not differ among the groups. In TROP eyes, cone discrimination was easier in offset aperture images. There was no evidence of cone loss in the TROP OCT images. CONCLUSIONS: Low cone density in TROP confocal SLO images may have resulted from lower image quality. Since AO correction in these eyes was equivalent to that of the control group, and OCT imaging showed no significant cone loss, the optical properties of the inner retina or properties of the cones themselves are likely altered in a way that affects photoreceptor imaging.
format Online
Article
Text
id pubmed-4758295
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-47582952016-08-01 Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity Ramamirtham, Ramkumar Akula, James D. Soni, Garima Swanson, Matthew J. Bush, Jennifer N. Moskowitz, Anne Swanson, Emily A. Favazza, Tara L. Tavormina, Jena L. Mujat, Mircea Ferguson, R. Daniel Hansen, Ronald M. Fulton, Anne B. Invest Ophthalmol Vis Sci Retina PURPOSE: To study the density and packing geometry of the extrafoveal cone photoreceptors in eyes with a history of retinopathy of prematurity (ROP). We used a multimodal combination of adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). METHODS: Cones were identified in subjects (aged 14–26 years) with a history of ROP that was either severe and treated by laser ablation of avascular peripheral retina (TROP; n = 5) or mild and spontaneously resolved, untreated (UROP; n = 5), and in term-born controls (CT; n = 8). The AO-SLO images were obtained at temporal eccentricities 4.5°, 9°, 13.5°, and 18° using both confocal and offset apertures with simultaneous, colocal OCT images. Effects of group, eccentricity, and aperture were evaluated and the modalities compared. RESULTS: In the SLO images, cone density was lower and the packing pattern less regular in TROP, relative to CT and UROP retinae. Although SLO image quality appeared lower in TROP, root mean square (RMS) wavefront error did not differ among the groups. In TROP eyes, cone discrimination was easier in offset aperture images. There was no evidence of cone loss in the TROP OCT images. CONCLUSIONS: Low cone density in TROP confocal SLO images may have resulted from lower image quality. Since AO correction in these eyes was equivalent to that of the control group, and OCT imaging showed no significant cone loss, the optical properties of the inner retina or properties of the cones themselves are likely altered in a way that affects photoreceptor imaging. The Association for Research in Vision and Ophthalmology 2016-02-11 2016-02 /pmc/articles/PMC4758295/ /pubmed/26868749 http://dx.doi.org/10.1167/iovs.15-17783 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Retina
Ramamirtham, Ramkumar
Akula, James D.
Soni, Garima
Swanson, Matthew J.
Bush, Jennifer N.
Moskowitz, Anne
Swanson, Emily A.
Favazza, Tara L.
Tavormina, Jena L.
Mujat, Mircea
Ferguson, R. Daniel
Hansen, Ronald M.
Fulton, Anne B.
Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title_full Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title_fullStr Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title_full_unstemmed Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title_short Extrafoveal Cone Packing in Eyes With a History of Retinopathy of Prematurity
title_sort extrafoveal cone packing in eyes with a history of retinopathy of prematurity
topic Retina
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4758295/
https://www.ncbi.nlm.nih.gov/pubmed/26868749
http://dx.doi.org/10.1167/iovs.15-17783
work_keys_str_mv AT ramamirthamramkumar extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT akulajamesd extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT sonigarima extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT swansonmatthewj extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT bushjennifern extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT moskowitzanne extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT swansonemilya extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT favazzataral extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT tavorminajenal extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT mujatmircea extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT fergusonrdaniel extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT hansenronaldm extrafovealconepackingineyeswithahistoryofretinopathyofprematurity
AT fultonanneb extrafovealconepackingineyeswithahistoryofretinopathyofprematurity