Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monito...

Descripción completa

Detalles Bibliográficos
Autores principales: Douma, K. W., Regterschot, G. R. H., Krijnen, W.P., Slager, G. E. C., van der Schans, C. P., Zijlstra, W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4759727/
https://www.ncbi.nlm.nih.gov/pubmed/26900478
http://dx.doi.org/10.1186/s13102-016-0029-x
_version_ 1782416773536022528
author Douma, K. W.
Regterschot, G. R. H.
Krijnen, W.P.
Slager, G. E. C.
van der Schans, C. P.
Zijlstra, W.
author_facet Douma, K. W.
Regterschot, G. R. H.
Krijnen, W.P.
Slager, G. E. C.
van der Schans, C. P.
Zijlstra, W.
author_sort Douma, K. W.
collection PubMed
description BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. METHODS: Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. RESULTS: Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of −18.6 N to 33.8 N and the right leg of −9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. CONCLUSION: The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments.
format Online
Article
Text
id pubmed-4759727
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47597272016-02-20 Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength Douma, K. W. Regterschot, G. R. H. Krijnen, W.P. Slager, G. E. C. van der Schans, C. P. Zijlstra, W. BMC Sports Sci Med Rehabil Research Article BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. METHODS: Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. RESULTS: Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of −18.6 N to 33.8 N and the right leg of −9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. CONCLUSION: The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments. BioMed Central 2016-02-19 /pmc/articles/PMC4759727/ /pubmed/26900478 http://dx.doi.org/10.1186/s13102-016-0029-x Text en © Douma et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Douma, K. W.
Regterschot, G. R. H.
Krijnen, W.P.
Slager, G. E. C.
van der Schans, C. P.
Zijlstra, W.
Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title_full Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title_fullStr Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title_full_unstemmed Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title_short Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
title_sort reliability of the q force; a mobile instrument for measuring isometric quadriceps muscle strength
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4759727/
https://www.ncbi.nlm.nih.gov/pubmed/26900478
http://dx.doi.org/10.1186/s13102-016-0029-x
work_keys_str_mv AT doumakw reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength
AT regterschotgrh reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength
AT krijnenwp reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength
AT slagergec reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength
AT vanderschanscp reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength
AT zijlstraw reliabilityoftheqforceamobileinstrumentformeasuringisometricquadricepsmusclestrength