Cargando…
Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method
To make an accurate estimation of the uptake of radioactivity in an organ using the conjugate view method, corrections of physical factors, such as background activity, scatter, and attenuation are needed. The aim of this study was to evaluate the accuracy of four different methods for background co...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4759842/ https://www.ncbi.nlm.nih.gov/pubmed/26955568 |
_version_ | 1782416793979060224 |
---|---|
author | Shanei, Ahmad Afshin, Maryam Moslehi, Masoud Rastaghi, Sedighe |
author_facet | Shanei, Ahmad Afshin, Maryam Moslehi, Masoud Rastaghi, Sedighe |
author_sort | Shanei, Ahmad |
collection | PubMed |
description | To make an accurate estimation of the uptake of radioactivity in an organ using the conjugate view method, corrections of physical factors, such as background activity, scatter, and attenuation are needed. The aim of this study was to evaluate the accuracy of four different methods for background correction in activity quantification of the heart in myocardial perfusion scans. The organ activity was calculated using the conjugate view method. A number of 22 healthy volunteers were injected with 17–19 mCi of (99m)Tc-methoxy-isobutyl-isonitrile (MIBI) at rest or during exercise. Images were obtained by a dual-headed gamma camera. Four methods for background correction were applied: (1) Conventional correction (referred to as the Gates' method), (2) Buijs method, (3) BgdA subtraction, (4) BgdB subtraction. To evaluate the accuracy of these methods, the results of the calculations using the above-mentioned methods were compared with the reference results. The calculated uptake in the heart using conventional method, Buijs method, BgdA subtraction, and BgdB subtraction methods was 1.4 ± 0.7% (P < 0.05), 2.6 ± 0.6% (P < 0.05), 1.3 ± 0.5% (P < 0.05), and 0.8 ± 0.3% (P < 0.05) of injected dose (I.D) at rest and 1.8 ± 0.6% (P > 0.05), 3.1 ± 0.8% (P > 0.05), 1.9 ± 0.8% (P < 0.05), and 1.2 ± 0.5% (P < 0.05) of I.D, during exercise. The mean estimated myocardial uptake of (99m)Tc-MIBI was dependent on the correction method used. Comparison among the four different methods of background activity correction applied in this study showed that the Buijs method was the most suitable method for background correction in myocardial perfusion scan. |
format | Online Article Text |
id | pubmed-4759842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-47598422016-03-07 Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method Shanei, Ahmad Afshin, Maryam Moslehi, Masoud Rastaghi, Sedighe J Med Signals Sens Original Article To make an accurate estimation of the uptake of radioactivity in an organ using the conjugate view method, corrections of physical factors, such as background activity, scatter, and attenuation are needed. The aim of this study was to evaluate the accuracy of four different methods for background correction in activity quantification of the heart in myocardial perfusion scans. The organ activity was calculated using the conjugate view method. A number of 22 healthy volunteers were injected with 17–19 mCi of (99m)Tc-methoxy-isobutyl-isonitrile (MIBI) at rest or during exercise. Images were obtained by a dual-headed gamma camera. Four methods for background correction were applied: (1) Conventional correction (referred to as the Gates' method), (2) Buijs method, (3) BgdA subtraction, (4) BgdB subtraction. To evaluate the accuracy of these methods, the results of the calculations using the above-mentioned methods were compared with the reference results. The calculated uptake in the heart using conventional method, Buijs method, BgdA subtraction, and BgdB subtraction methods was 1.4 ± 0.7% (P < 0.05), 2.6 ± 0.6% (P < 0.05), 1.3 ± 0.5% (P < 0.05), and 0.8 ± 0.3% (P < 0.05) of injected dose (I.D) at rest and 1.8 ± 0.6% (P > 0.05), 3.1 ± 0.8% (P > 0.05), 1.9 ± 0.8% (P < 0.05), and 1.2 ± 0.5% (P < 0.05) of I.D, during exercise. The mean estimated myocardial uptake of (99m)Tc-MIBI was dependent on the correction method used. Comparison among the four different methods of background activity correction applied in this study showed that the Buijs method was the most suitable method for background correction in myocardial perfusion scan. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4759842/ /pubmed/26955568 Text en Copyright: © 2015 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Shanei, Ahmad Afshin, Maryam Moslehi, Masoud Rastaghi, Sedighe Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title | Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title_full | Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title_fullStr | Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title_full_unstemmed | Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title_short | Estimation of Organ Activity using Four Different Methods of Background Correction in Conjugate View Method |
title_sort | estimation of organ activity using four different methods of background correction in conjugate view method |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4759842/ https://www.ncbi.nlm.nih.gov/pubmed/26955568 |
work_keys_str_mv | AT shaneiahmad estimationoforganactivityusingfourdifferentmethodsofbackgroundcorrectioninconjugateviewmethod AT afshinmaryam estimationoforganactivityusingfourdifferentmethodsofbackgroundcorrectioninconjugateviewmethod AT moslehimasoud estimationoforganactivityusingfourdifferentmethodsofbackgroundcorrectioninconjugateviewmethod AT rastaghisedighe estimationoforganactivityusingfourdifferentmethodsofbackgroundcorrectioninconjugateviewmethod |