Cargando…
Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4761607/ https://www.ncbi.nlm.nih.gov/pubmed/26929794 http://dx.doi.org/10.4055/cios.2016.8.1.9 |
_version_ | 1782416983917068288 |
---|---|
author | Jung, Sung-Weon Kang, Seung-Hoon Jeong, Min Lim, Hae-Seong |
author_facet | Jung, Sung-Weon Kang, Seung-Hoon Jeong, Min Lim, Hae-Seong |
author_sort | Jung, Sung-Weon |
collection | PubMed |
description | BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar fracture. METHODS: This study included 38 patients (15 males and 23 females) who underwent olecranon osteotomy, open reduction and internal fixation with the triangle-shaped cannulated screw and parallel locking plates (triangular fixation technique). Functional results were assessed with the visual analog scale (VAS) scores, Mayo elbow performance (MEP) scores and Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires. Anteroposterior and lateral elbow radiographs were assessed for reduction, alignment, fracture union, posttraumatic arthrosis, and heterotopic ossification, and computed tomography (CT) scans were used to obtain more accurate measurements of articular discrepancy. RESULTS: All fractures healed primarily with no loss of reduction. The mean VAS, MEP, and DASH scores of the affected elbow were not significantly different from those of the unaffected elbow (p = 0.140, p = 0.090, and p = 0.262, respectively). The mean degree of flexion was significantly lower in the affected elbow than in the unaffected elbow, but was still considered as functional (p = 0.001, > 100° in 33 of 38 patients). Two cases of articular step-offs (> 2 mm) were seen on follow-up CT scans, but not significantly higher in the affected elbow than in the unaffected elbow (p = 0.657). Binary logistic regression analysis revealed that only Association for Osteosynthesis (AO) type C3 fractures correlated with good/excellent functional outcome (p = 0.012). Complications occurred in 12 of the 38 patients, and the overall reoperation rate for complications was 10.5% (4 of 38 patients). CONCLUSIONS: Triangular fixation technique for bicolumn restoration was an effective and reliable method in treatment of distal humerus intercondylar fracture. This technique maintained articular congruency and restored both medial and lateral columns, resulting in good elbow function. |
format | Online Article Text |
id | pubmed-4761607 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-47616072016-03-01 Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture Jung, Sung-Weon Kang, Seung-Hoon Jeong, Min Lim, Hae-Seong Clin Orthop Surg Original Article BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar fracture. METHODS: This study included 38 patients (15 males and 23 females) who underwent olecranon osteotomy, open reduction and internal fixation with the triangle-shaped cannulated screw and parallel locking plates (triangular fixation technique). Functional results were assessed with the visual analog scale (VAS) scores, Mayo elbow performance (MEP) scores and Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires. Anteroposterior and lateral elbow radiographs were assessed for reduction, alignment, fracture union, posttraumatic arthrosis, and heterotopic ossification, and computed tomography (CT) scans were used to obtain more accurate measurements of articular discrepancy. RESULTS: All fractures healed primarily with no loss of reduction. The mean VAS, MEP, and DASH scores of the affected elbow were not significantly different from those of the unaffected elbow (p = 0.140, p = 0.090, and p = 0.262, respectively). The mean degree of flexion was significantly lower in the affected elbow than in the unaffected elbow, but was still considered as functional (p = 0.001, > 100° in 33 of 38 patients). Two cases of articular step-offs (> 2 mm) were seen on follow-up CT scans, but not significantly higher in the affected elbow than in the unaffected elbow (p = 0.657). Binary logistic regression analysis revealed that only Association for Osteosynthesis (AO) type C3 fractures correlated with good/excellent functional outcome (p = 0.012). Complications occurred in 12 of the 38 patients, and the overall reoperation rate for complications was 10.5% (4 of 38 patients). CONCLUSIONS: Triangular fixation technique for bicolumn restoration was an effective and reliable method in treatment of distal humerus intercondylar fracture. This technique maintained articular congruency and restored both medial and lateral columns, resulting in good elbow function. The Korean Orthopaedic Association 2016-03 2016-02-13 /pmc/articles/PMC4761607/ /pubmed/26929794 http://dx.doi.org/10.4055/cios.2016.8.1.9 Text en Copyright © 2016 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Jung, Sung-Weon Kang, Seung-Hoon Jeong, Min Lim, Hae-Seong Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title | Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title_full | Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title_fullStr | Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title_full_unstemmed | Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title_short | Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture |
title_sort | triangular fixation technique for bicolumn restoration in treatment of distal humerus intercondylar fracture |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4761607/ https://www.ncbi.nlm.nih.gov/pubmed/26929794 http://dx.doi.org/10.4055/cios.2016.8.1.9 |
work_keys_str_mv | AT jungsungweon triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture AT kangseunghoon triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture AT jeongmin triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture AT limhaeseong triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture |