Cargando…

Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture

BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Sung-Weon, Kang, Seung-Hoon, Jeong, Min, Lim, Hae-Seong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4761607/
https://www.ncbi.nlm.nih.gov/pubmed/26929794
http://dx.doi.org/10.4055/cios.2016.8.1.9
_version_ 1782416983917068288
author Jung, Sung-Weon
Kang, Seung-Hoon
Jeong, Min
Lim, Hae-Seong
author_facet Jung, Sung-Weon
Kang, Seung-Hoon
Jeong, Min
Lim, Hae-Seong
author_sort Jung, Sung-Weon
collection PubMed
description BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar fracture. METHODS: This study included 38 patients (15 males and 23 females) who underwent olecranon osteotomy, open reduction and internal fixation with the triangle-shaped cannulated screw and parallel locking plates (triangular fixation technique). Functional results were assessed with the visual analog scale (VAS) scores, Mayo elbow performance (MEP) scores and Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires. Anteroposterior and lateral elbow radiographs were assessed for reduction, alignment, fracture union, posttraumatic arthrosis, and heterotopic ossification, and computed tomography (CT) scans were used to obtain more accurate measurements of articular discrepancy. RESULTS: All fractures healed primarily with no loss of reduction. The mean VAS, MEP, and DASH scores of the affected elbow were not significantly different from those of the unaffected elbow (p = 0.140, p = 0.090, and p = 0.262, respectively). The mean degree of flexion was significantly lower in the affected elbow than in the unaffected elbow, but was still considered as functional (p = 0.001, > 100° in 33 of 38 patients). Two cases of articular step-offs (> 2 mm) were seen on follow-up CT scans, but not significantly higher in the affected elbow than in the unaffected elbow (p = 0.657). Binary logistic regression analysis revealed that only Association for Osteosynthesis (AO) type C3 fractures correlated with good/excellent functional outcome (p = 0.012). Complications occurred in 12 of the 38 patients, and the overall reoperation rate for complications was 10.5% (4 of 38 patients). CONCLUSIONS: Triangular fixation technique for bicolumn restoration was an effective and reliable method in treatment of distal humerus intercondylar fracture. This technique maintained articular congruency and restored both medial and lateral columns, resulting in good elbow function.
format Online
Article
Text
id pubmed-4761607
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-47616072016-03-01 Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture Jung, Sung-Weon Kang, Seung-Hoon Jeong, Min Lim, Hae-Seong Clin Orthop Surg Original Article BACKGROUND: Distal humerus intercondylar fractures are intra-articular and comminuted fractures involving soft tissue injury. As distal humerus is triangle-shaped, parallel plating coupled with articular fixation would be suitable for bicolumn restoration in treatment of distal humerus intercondylar fracture. METHODS: This study included 38 patients (15 males and 23 females) who underwent olecranon osteotomy, open reduction and internal fixation with the triangle-shaped cannulated screw and parallel locking plates (triangular fixation technique). Functional results were assessed with the visual analog scale (VAS) scores, Mayo elbow performance (MEP) scores and Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires. Anteroposterior and lateral elbow radiographs were assessed for reduction, alignment, fracture union, posttraumatic arthrosis, and heterotopic ossification, and computed tomography (CT) scans were used to obtain more accurate measurements of articular discrepancy. RESULTS: All fractures healed primarily with no loss of reduction. The mean VAS, MEP, and DASH scores of the affected elbow were not significantly different from those of the unaffected elbow (p = 0.140, p = 0.090, and p = 0.262, respectively). The mean degree of flexion was significantly lower in the affected elbow than in the unaffected elbow, but was still considered as functional (p = 0.001, > 100° in 33 of 38 patients). Two cases of articular step-offs (> 2 mm) were seen on follow-up CT scans, but not significantly higher in the affected elbow than in the unaffected elbow (p = 0.657). Binary logistic regression analysis revealed that only Association for Osteosynthesis (AO) type C3 fractures correlated with good/excellent functional outcome (p = 0.012). Complications occurred in 12 of the 38 patients, and the overall reoperation rate for complications was 10.5% (4 of 38 patients). CONCLUSIONS: Triangular fixation technique for bicolumn restoration was an effective and reliable method in treatment of distal humerus intercondylar fracture. This technique maintained articular congruency and restored both medial and lateral columns, resulting in good elbow function. The Korean Orthopaedic Association 2016-03 2016-02-13 /pmc/articles/PMC4761607/ /pubmed/26929794 http://dx.doi.org/10.4055/cios.2016.8.1.9 Text en Copyright © 2016 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jung, Sung-Weon
Kang, Seung-Hoon
Jeong, Min
Lim, Hae-Seong
Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title_full Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title_fullStr Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title_full_unstemmed Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title_short Triangular Fixation Technique for Bicolumn Restoration in Treatment of Distal Humerus Intercondylar Fracture
title_sort triangular fixation technique for bicolumn restoration in treatment of distal humerus intercondylar fracture
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4761607/
https://www.ncbi.nlm.nih.gov/pubmed/26929794
http://dx.doi.org/10.4055/cios.2016.8.1.9
work_keys_str_mv AT jungsungweon triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture
AT kangseunghoon triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture
AT jeongmin triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture
AT limhaeseong triangularfixationtechniqueforbicolumnrestorationintreatmentofdistalhumerusintercondylarfracture