Cargando…

Evaluation of flexural strength and color stability of different denture base materials including flexible material after using different denture cleansers

AIMS: Present study aimed at evaluating the colour stability and flexural strength of flexible denture base materials (Valplast) and Polymethyl methacrylate (PMMA) denture base material (Meliodent) processed by two different methods (Injection moulding and compression moulding) after immersing them...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Vrinda R., Shah, Darshana Nilesh, Chauhan, Chirag J., Doshi, Paras J., Kumar, Ashish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4762351/
https://www.ncbi.nlm.nih.gov/pubmed/26929541
http://dx.doi.org/10.4103/0972-4052.164908
Descripción
Sumario:AIMS: Present study aimed at evaluating the colour stability and flexural strength of flexible denture base materials (Valplast) and Polymethyl methacrylate (PMMA) denture base material (Meliodent) processed by two different methods (Injection moulding and compression moulding) after immersing them in three different denture cleansers with acidic, basic and neutral PH. METHODS AND MATERIALS: Total 120 specimens (65 × 10 × 3 mm3), 40 specimens of each material (Valplast, Meliodent compression moulding and injection moulding) were immersed in denture cleansers having different PH; Valclean (Acidic), Clinsodent (Basic) and Polident (Neutral) as well as Distilled Water. Color changes were measured with a spectrophotometer after 1 month, 3 months and 6 months of immersion cycle. A flexural 3-point bending test was carried out by using an Instron universal testing machine after 6 months of soaking. Data were analyzed using SPSS software RESULTS: Maximum effect on colour stability was noted with Clinsodent followed by Valclean. Least color changes were observed after immersion in Polident. Colour difference was increased significantly as the immersion time increased. For both Meliodent and Nylon resins, statistically significant change in flexural strength occurred with immersion in all denture cleansers. Clinsodent has greater effect as compared to Valclean and Polident. CONCLUSIONS: Polident and Valclean can be safely used as denture cleanser for both nylon and acrylic resin denture base materials as far as colour stability and flexural strength both are concerned.