Cargando…
A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser
AIM: The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery. MATERIAL AND METHOD: For the validation of this new semi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4762705/ https://www.ncbi.nlm.nih.gov/pubmed/26901524 http://dx.doi.org/10.1371/journal.pone.0149625 |
_version_ | 1782417146298499072 |
---|---|
author | Baan, Frank Liebregts, Jeroen Xi, Tong Schreurs, Ruud de Koning, Martien Bergé, Stefaan Maal, Thomas |
author_facet | Baan, Frank Liebregts, Jeroen Xi, Tong Schreurs, Ruud de Koning, Martien Bergé, Stefaan Maal, Thomas |
author_sort | Baan, Frank |
collection | PubMed |
description | AIM: The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery. MATERIAL AND METHOD: For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times. RESULTS: Low intra-observer and inter-observer variations in measurement error (mean error < 0.25 mm) and high intraclass correlation coefficients (> 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively. CONCLUSION: This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery. |
format | Online Article Text |
id | pubmed-4762705 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47627052016-03-07 A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser Baan, Frank Liebregts, Jeroen Xi, Tong Schreurs, Ruud de Koning, Martien Bergé, Stefaan Maal, Thomas PLoS One Research Article AIM: The purpose of this study was to present and validate an innovative semi-automatic approach to quantify the accuracy of the surgical outcome in relation to 3D virtual orthognathic planning among patients who underwent bimaxillary surgery. MATERIAL AND METHOD: For the validation of this new semi-automatic approach, CBCT scans of ten patients who underwent bimaxillary surgery were acquired pre-operatively. Individualized 3D virtual operation plans were made for all patients prior to surgery. During surgery, the maxillary and mandibular segments were positioned as planned by using 3D milled interocclusal wafers. Consequently, post-operative CBCT scan were acquired. The 3D rendered pre- and postoperative virtual head models were aligned by voxel-based registration upon the anterior cranial base. To calculate the discrepancies between the 3D planning and the actual surgical outcome, the 3D planned maxillary and mandibular segments were segmented and superimposed upon the postoperative maxillary and mandibular segments. The translation matrices obtained from this registration process were translated into translational and rotational discrepancies between the 3D planning and the surgical outcome, by using the newly developed tool, the OrthoGnathicAnalyser. To evaluate the reproducibility of this method, the process was performed by two independent observers multiple times. RESULTS: Low intra-observer and inter-observer variations in measurement error (mean error < 0.25 mm) and high intraclass correlation coefficients (> 0.97) were found, supportive of the observer independent character of the OrthoGnathicAnalyser. The pitch of the maxilla and mandible showed the highest discrepancy between the 3D planning and the postoperative results, 2.72° and 2.75° respectively. CONCLUSION: This novel method provides a reproducible tool for the evaluation of bimaxillary surgery, making it possible to compare larger patient groups in an objective and time-efficient manner in order to optimize the current workflow in orthognathic surgery. Public Library of Science 2016-02-22 /pmc/articles/PMC4762705/ /pubmed/26901524 http://dx.doi.org/10.1371/journal.pone.0149625 Text en © 2016 Baan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Baan, Frank Liebregts, Jeroen Xi, Tong Schreurs, Ruud de Koning, Martien Bergé, Stefaan Maal, Thomas A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title | A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title_full | A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title_fullStr | A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title_full_unstemmed | A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title_short | A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser |
title_sort | new 3d tool for assessing the accuracy of bimaxillary surgery: the orthognathicanalyser |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4762705/ https://www.ncbi.nlm.nih.gov/pubmed/26901524 http://dx.doi.org/10.1371/journal.pone.0149625 |
work_keys_str_mv | AT baanfrank anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT liebregtsjeroen anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT xitong anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT schreursruud anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT dekoningmartien anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT bergestefaan anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT maalthomas anew3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT baanfrank new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT liebregtsjeroen new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT xitong new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT schreursruud new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT dekoningmartien new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT bergestefaan new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser AT maalthomas new3dtoolforassessingtheaccuracyofbimaxillarysurgerytheorthognathicanalyser |