Cargando…
A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replace...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4763257/ https://www.ncbi.nlm.nih.gov/pubmed/26903199 http://dx.doi.org/10.1038/srep21369 |
_version_ | 1782417235319455744 |
---|---|
author | Sung, Tzu-Cheng Chen, Wen-Yih Shah, Pramod Chen, Chien-Sheng |
author_facet | Sung, Tzu-Cheng Chen, Wen-Yih Shah, Pramod Chen, Chien-Sheng |
author_sort | Sung, Tzu-Cheng |
collection | PubMed |
description | Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays. |
format | Online Article Text |
id | pubmed-4763257 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-47632572016-03-01 A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin Sung, Tzu-Cheng Chen, Wen-Yih Shah, Pramod Chen, Chien-Sheng Sci Rep Article Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays. Nature Publishing Group 2016-02-23 /pmc/articles/PMC4763257/ /pubmed/26903199 http://dx.doi.org/10.1038/srep21369 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Sung, Tzu-Cheng Chen, Wen-Yih Shah, Pramod Chen, Chien-Sheng A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title | A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title_full | A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title_fullStr | A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title_full_unstemmed | A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title_short | A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
title_sort | replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4763257/ https://www.ncbi.nlm.nih.gov/pubmed/26903199 http://dx.doi.org/10.1038/srep21369 |
work_keys_str_mv | AT sungtzucheng areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT chenwenyih areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT shahpramod areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT chenchiensheng areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT sungtzucheng replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT chenwenyih replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT shahpramod replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin AT chenchiensheng replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin |