Cargando…

A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin

Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replace...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Tzu-Cheng, Chen, Wen-Yih, Shah, Pramod, Chen, Chien-Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4763257/
https://www.ncbi.nlm.nih.gov/pubmed/26903199
http://dx.doi.org/10.1038/srep21369
_version_ 1782417235319455744
author Sung, Tzu-Cheng
Chen, Wen-Yih
Shah, Pramod
Chen, Chien-Sheng
author_facet Sung, Tzu-Cheng
Chen, Wen-Yih
Shah, Pramod
Chen, Chien-Sheng
author_sort Sung, Tzu-Cheng
collection PubMed
description Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays.
format Online
Article
Text
id pubmed-4763257
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-47632572016-03-01 A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin Sung, Tzu-Cheng Chen, Wen-Yih Shah, Pramod Chen, Chien-Sheng Sci Rep Article Biotin is an essential vitamin which plays an important role for maintaining normal physiological function. A rapid, sensitive, and simple method is necessary to monitor the biotin level. Here, we reported a replacement assay for the detection of biotin using a replaceable liposomal aptamer. Replacement assay is a competitive assay where a sample analyte replaces the labeled competitor of analyte out of its biorecognition element on a surface. It is user friendly and time-saving because of washing free. We used aptamer as a competitor, not a biorecognition element as tradition. To label aptamers, we used cholesterol-conjugated aptamers to tag signal-amplifying-liposomes. Without the need of conjugation procedure, aptamers can be easily incorporated into the surface of dye-encapsulating liposomes. Two aptamers as competitors of biotin, ST-21 and ST-21M with different affinities to streptavidin, were studied in parallel for the detection of biotin using replacement assays. ST-21 and ST-21M aptamers reached to limits of detection of 1.32 pg/80 μl and 0.47 pg/80 μl, respectively. The dynamic ranges of our assays using ST-21 and ST-21M aptamers were seven and four orders of magnitude, respectively. This assay can be completed in 20 minutes without washing steps. These results were overall better than previous reported assays. Nature Publishing Group 2016-02-23 /pmc/articles/PMC4763257/ /pubmed/26903199 http://dx.doi.org/10.1038/srep21369 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Sung, Tzu-Cheng
Chen, Wen-Yih
Shah, Pramod
Chen, Chien-Sheng
A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title_full A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title_fullStr A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title_full_unstemmed A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title_short A replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
title_sort replaceable liposomal aptamer for the ultrasensitive and rapid detection of biotin
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4763257/
https://www.ncbi.nlm.nih.gov/pubmed/26903199
http://dx.doi.org/10.1038/srep21369
work_keys_str_mv AT sungtzucheng areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT chenwenyih areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT shahpramod areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT chenchiensheng areplaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT sungtzucheng replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT chenwenyih replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT shahpramod replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin
AT chenchiensheng replaceableliposomalaptamerfortheultrasensitiveandrapiddetectionofbiotin