Cargando…

Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants

BACKGROUND: Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate e...

Descripción completa

Detalles Bibliográficos
Autores principales: O’Brien, Caroline C., Kolandaivelu, Kumaran, Brown, Jonathan, Lopes, Augusto C., Kunio, Mie, Kolachalama, Vijaya B., Edelman, Elazer R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764338/
https://www.ncbi.nlm.nih.gov/pubmed/26906566
http://dx.doi.org/10.1371/journal.pone.0149178
_version_ 1782417370428473344
author O’Brien, Caroline C.
Kolandaivelu, Kumaran
Brown, Jonathan
Lopes, Augusto C.
Kunio, Mie
Kolachalama, Vijaya B.
Edelman, Elazer R.
author_facet O’Brien, Caroline C.
Kolandaivelu, Kumaran
Brown, Jonathan
Lopes, Augusto C.
Kunio, Mie
Kolachalama, Vijaya B.
Edelman, Elazer R.
author_sort O’Brien, Caroline C.
collection PubMed
description BACKGROUND: Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. METHODS AND RESULTS: Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D ‘clouds’ of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r(2) = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. CONCLUSION: Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
format Online
Article
Text
id pubmed-4764338
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47643382016-03-07 Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants O’Brien, Caroline C. Kolandaivelu, Kumaran Brown, Jonathan Lopes, Augusto C. Kunio, Mie Kolachalama, Vijaya B. Edelman, Elazer R. PLoS One Research Article BACKGROUND: Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. METHODS AND RESULTS: Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D ‘clouds’ of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r(2) = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. CONCLUSION: Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments. Public Library of Science 2016-02-23 /pmc/articles/PMC4764338/ /pubmed/26906566 http://dx.doi.org/10.1371/journal.pone.0149178 Text en © 2016 O’Brien et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
O’Brien, Caroline C.
Kolandaivelu, Kumaran
Brown, Jonathan
Lopes, Augusto C.
Kunio, Mie
Kolachalama, Vijaya B.
Edelman, Elazer R.
Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title_full Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title_fullStr Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title_full_unstemmed Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title_short Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
title_sort constraining oct with knowledge of device design enables high accuracy hemodynamic assessment of endovascular implants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764338/
https://www.ncbi.nlm.nih.gov/pubmed/26906566
http://dx.doi.org/10.1371/journal.pone.0149178
work_keys_str_mv AT obriencarolinec constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT kolandaivelukumaran constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT brownjonathan constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT lopesaugustoc constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT kuniomie constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT kolachalamavijayab constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants
AT edelmanelazerr constrainingoctwithknowledgeofdevicedesignenableshighaccuracyhemodynamicassessmentofendovascularimplants