Cargando…
Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT
Objective. To compare the image quality of coronary computed tomography angiography (CCTA) acquired under two conditions: 75% fixed as the acquisition window center (Group 75%) and the diagnostic phase for calcium scoring scan as the center (CS; Group CS). Methods. 320-row cardiac CT with a minimal...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764755/ https://www.ncbi.nlm.nih.gov/pubmed/26977449 http://dx.doi.org/10.1155/2016/1017851 |
_version_ | 1782417431679991808 |
---|---|
author | Maeda, Eriko Yamamoto, Kodai Kanno, Shigeaki Ino, Kenji Tomizawa, Nobuo Akahane, Masaaki Torigoe, Rumiko Ohtomo, Kuni |
author_facet | Maeda, Eriko Yamamoto, Kodai Kanno, Shigeaki Ino, Kenji Tomizawa, Nobuo Akahane, Masaaki Torigoe, Rumiko Ohtomo, Kuni |
author_sort | Maeda, Eriko |
collection | PubMed |
description | Objective. To compare the image quality of coronary computed tomography angiography (CCTA) acquired under two conditions: 75% fixed as the acquisition window center (Group 75%) and the diagnostic phase for calcium scoring scan as the center (CS; Group CS). Methods. 320-row cardiac CT with a minimal acquisition window (scanned using “Target CTA” mode) was performed on 81 patients. In Group 75% (n = 40), CS was obtained and reconstructed at 75% and the center of the CCTA acquisition window was set at 75%. In Group CS (n = 41), CS was obtained at 75% and the diagnostic phase showing minimal artifacts was applied as the center of the CCTA acquisition window. Image quality was evaluated using a four-point scale (4-excellent) and the mean scores were compared between groups. Results. The CCTA scan diagnostic phase occurred significantly earlier in CS (75.7 ± 3.2% vs. 73.6 ± 4.5% for Groups 75% and CS, resp., p = 0.013). The mean Group CS image quality score (3.58 ± 0.63) was also higher than that for Group 75% (3.19 ± 0.66, p < 0.0001). Conclusions. The image quality of CCTA in Target CTA mode was significantly better when the center of acquisition window is adjusted using CS. |
format | Online Article Text |
id | pubmed-4764755 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47647552016-03-14 Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT Maeda, Eriko Yamamoto, Kodai Kanno, Shigeaki Ino, Kenji Tomizawa, Nobuo Akahane, Masaaki Torigoe, Rumiko Ohtomo, Kuni ScientificWorldJournal Research Article Objective. To compare the image quality of coronary computed tomography angiography (CCTA) acquired under two conditions: 75% fixed as the acquisition window center (Group 75%) and the diagnostic phase for calcium scoring scan as the center (CS; Group CS). Methods. 320-row cardiac CT with a minimal acquisition window (scanned using “Target CTA” mode) was performed on 81 patients. In Group 75% (n = 40), CS was obtained and reconstructed at 75% and the center of the CCTA acquisition window was set at 75%. In Group CS (n = 41), CS was obtained at 75% and the diagnostic phase showing minimal artifacts was applied as the center of the CCTA acquisition window. Image quality was evaluated using a four-point scale (4-excellent) and the mean scores were compared between groups. Results. The CCTA scan diagnostic phase occurred significantly earlier in CS (75.7 ± 3.2% vs. 73.6 ± 4.5% for Groups 75% and CS, resp., p = 0.013). The mean Group CS image quality score (3.58 ± 0.63) was also higher than that for Group 75% (3.19 ± 0.66, p < 0.0001). Conclusions. The image quality of CCTA in Target CTA mode was significantly better when the center of acquisition window is adjusted using CS. Hindawi Publishing Corporation 2016 2016-02-10 /pmc/articles/PMC4764755/ /pubmed/26977449 http://dx.doi.org/10.1155/2016/1017851 Text en Copyright © 2016 Eriko Maeda et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Maeda, Eriko Yamamoto, Kodai Kanno, Shigeaki Ino, Kenji Tomizawa, Nobuo Akahane, Masaaki Torigoe, Rumiko Ohtomo, Kuni Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title | Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title_full | Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title_fullStr | Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title_full_unstemmed | Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title_short | Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT |
title_sort | diagnostic phase of calcium scoring scan applied as the center of acquisition window of coronary computed tomography angiography improves image quality in minimal acquisition window scan (target cta mode) using the second generation 320-row ct |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764755/ https://www.ncbi.nlm.nih.gov/pubmed/26977449 http://dx.doi.org/10.1155/2016/1017851 |
work_keys_str_mv | AT maedaeriko diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT yamamotokodai diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT kannoshigeaki diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT inokenji diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT tomizawanobuo diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT akahanemasaaki diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT torigoerumiko diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct AT ohtomokuni diagnosticphaseofcalciumscoringscanappliedasthecenterofacquisitionwindowofcoronarycomputedtomographyangiographyimprovesimagequalityinminimalacquisitionwindowscantargetctamodeusingthesecondgeneration320rowct |