Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio
Objective: The aim was to investigate the relationship between the dimensions (length, width, and thickness) of random advancement skin flaps and retained tissue perfusion and oxygenation. Methods: Flaps were raised on the flanks of pigs. The flaps were either 0.5 or 1.0 cm wide, thin (dissected hal...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Open Science Company, LLC
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764830/ https://www.ncbi.nlm.nih.gov/pubmed/26958105 |
_version_ | 1782417446548799488 |
---|---|
author | Memarzadeh, Khashayar Sheikh, Rafi Blohmé, Jonas Torbrand, Christian Malmsjö, Malin |
author_facet | Memarzadeh, Khashayar Sheikh, Rafi Blohmé, Jonas Torbrand, Christian Malmsjö, Malin |
author_sort | Memarzadeh, Khashayar |
collection | PubMed |
description | Objective: The aim was to investigate the relationship between the dimensions (length, width, and thickness) of random advancement skin flaps and retained tissue perfusion and oxygenation. Methods: Flaps were raised on the flanks of pigs. The flaps were either 0.5 or 1.0 cm wide, thin (dissected halfway through the subcutaneous tissue) or thick (dissected down to the muscle fascia). Tissue perfusion was measured by laser Doppler velocimetry, and tissue oxygenation (pO(2)) was measured using a Licox system, every 0.5 cm along the flaps’ length. Tissue temperature was visualized by high-resolution infrared camera. Results: Perfusion and oxygenation decreased gradually from the base to the tip of the flap, reaching approximately 40% of presurgical values (2.0 cm) and approximately 20% (2.5 cm) from the base of the flap. There was virtually no blood flow, nor oxygen tension, 3.0 cm from the base of the flap. The width to length ratio of the flap did not determine blood flow or oxygenation, being approximately 30% in a 0.5 cm wide and 2 cm long flap, and 0% in a 1.0 cm wide and 4 cm long flap, both with a width to length ratio of 1:4. Blood flow and oxygenation were preserved to a greater extent in the thick flaps (∼40%) than in the thin flaps (∼20%), in a 0.5 cm wide and 2 cm long flap. Conclusions: The dissection of a random advancement flap results in hypoperfusion and oxygenation that cannot be predicted by the width to length ratio but depend on the length and thickness of the flap. |
format | Online Article Text |
id | pubmed-4764830 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Open Science Company, LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-47648302016-03-08 Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio Memarzadeh, Khashayar Sheikh, Rafi Blohmé, Jonas Torbrand, Christian Malmsjö, Malin Eplasty Journal Article Objective: The aim was to investigate the relationship between the dimensions (length, width, and thickness) of random advancement skin flaps and retained tissue perfusion and oxygenation. Methods: Flaps were raised on the flanks of pigs. The flaps were either 0.5 or 1.0 cm wide, thin (dissected halfway through the subcutaneous tissue) or thick (dissected down to the muscle fascia). Tissue perfusion was measured by laser Doppler velocimetry, and tissue oxygenation (pO(2)) was measured using a Licox system, every 0.5 cm along the flaps’ length. Tissue temperature was visualized by high-resolution infrared camera. Results: Perfusion and oxygenation decreased gradually from the base to the tip of the flap, reaching approximately 40% of presurgical values (2.0 cm) and approximately 20% (2.5 cm) from the base of the flap. There was virtually no blood flow, nor oxygen tension, 3.0 cm from the base of the flap. The width to length ratio of the flap did not determine blood flow or oxygenation, being approximately 30% in a 0.5 cm wide and 2 cm long flap, and 0% in a 1.0 cm wide and 4 cm long flap, both with a width to length ratio of 1:4. Blood flow and oxygenation were preserved to a greater extent in the thick flaps (∼40%) than in the thin flaps (∼20%), in a 0.5 cm wide and 2 cm long flap. Conclusions: The dissection of a random advancement flap results in hypoperfusion and oxygenation that cannot be predicted by the width to length ratio but depend on the length and thickness of the flap. Open Science Company, LLC 2016-02-19 /pmc/articles/PMC4764830/ /pubmed/26958105 Text en Copyright © 2016 The Author(s) http://creativecommons.org/licenses/by/2.0/ This is an open-access article whereby the authors retain copyright of the work. The article is distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Journal Article Memarzadeh, Khashayar Sheikh, Rafi Blohmé, Jonas Torbrand, Christian Malmsjö, Malin Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title | Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title_full | Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title_fullStr | Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title_full_unstemmed | Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title_short | Perfusion and Oxygenation of Random Advancement Skin Flaps Depend More on the Length and Thickness of the Flap Than on the Width to Length Ratio |
title_sort | perfusion and oxygenation of random advancement skin flaps depend more on the length and thickness of the flap than on the width to length ratio |
topic | Journal Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4764830/ https://www.ncbi.nlm.nih.gov/pubmed/26958105 |
work_keys_str_mv | AT memarzadehkhashayar perfusionandoxygenationofrandomadvancementskinflapsdependmoreonthelengthandthicknessoftheflapthanonthewidthtolengthratio AT sheikhrafi perfusionandoxygenationofrandomadvancementskinflapsdependmoreonthelengthandthicknessoftheflapthanonthewidthtolengthratio AT blohmejonas perfusionandoxygenationofrandomadvancementskinflapsdependmoreonthelengthandthicknessoftheflapthanonthewidthtolengthratio AT torbrandchristian perfusionandoxygenationofrandomadvancementskinflapsdependmoreonthelengthandthicknessoftheflapthanonthewidthtolengthratio AT malmsjomalin perfusionandoxygenationofrandomadvancementskinflapsdependmoreonthelengthandthicknessoftheflapthanonthewidthtolengthratio |