Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring

BACKGROUND: This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. METHODS: Macrostructure implants using a taper integr...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Shao-Fu, Chen, Wan-Rung, Lin, Chun-Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4765056/
https://www.ncbi.nlm.nih.gov/pubmed/26912169
http://dx.doi.org/10.1186/s12938-016-0140-y
_version_ 1782417492131446784
author Huang, Shao-Fu
Chen, Wan-Rung
Lin, Chun-Li
author_facet Huang, Shao-Fu
Chen, Wan-Rung
Lin, Chun-Li
author_sort Huang, Shao-Fu
collection PubMed
description BACKGROUND: This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. METHODS: Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. RESULT: The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. CONCLUSIONS: Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown.
format Online
Article
Text
id pubmed-4765056
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47650562016-02-25 Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring Huang, Shao-Fu Chen, Wan-Rung Lin, Chun-Li Biomed Eng Online Research BACKGROUND: This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. METHODS: Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. RESULT: The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. CONCLUSIONS: Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown. BioMed Central 2016-02-24 /pmc/articles/PMC4765056/ /pubmed/26912169 http://dx.doi.org/10.1186/s12938-016-0140-y Text en © Huang et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Huang, Shao-Fu
Chen, Wan-Rung
Lin, Chun-Li
Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title_full Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title_fullStr Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title_full_unstemmed Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title_short Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
title_sort biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4765056/
https://www.ncbi.nlm.nih.gov/pubmed/26912169
http://dx.doi.org/10.1186/s12938-016-0140-y
work_keys_str_mv AT huangshaofu biomechanicalinteractionsofendodonticallytreatedtoothimplantsupportedprosthesisunderfatiguetestwithacousticemissionmonitoring
AT chenwanrung biomechanicalinteractionsofendodonticallytreatedtoothimplantsupportedprosthesisunderfatiguetestwithacousticemissionmonitoring
AT linchunli biomechanicalinteractionsofendodonticallytreatedtoothimplantsupportedprosthesisunderfatiguetestwithacousticemissionmonitoring