Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries?
BACKGROUND: Spinal cord stimulation is currently approved to treat chronic intractable pain of the trunk and limbs. However, such implantable electronic devices are vulnerable to external electrical currents and magnetic fields. Within the hospitals and modern operating rooms (ORs), there is an abun...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4766801/ https://www.ncbi.nlm.nih.gov/pubmed/26958424 http://dx.doi.org/10.4103/2152-7806.176373 |
_version_ | 1782417734689095680 |
---|---|
author | Ghaly, Ramsis F. Tverdohleb, Tatiana Candido, Kenneth D. Knezevic, Nebojsa Nick |
author_facet | Ghaly, Ramsis F. Tverdohleb, Tatiana Candido, Kenneth D. Knezevic, Nebojsa Nick |
author_sort | Ghaly, Ramsis F. |
collection | PubMed |
description | BACKGROUND: Spinal cord stimulation is currently approved to treat chronic intractable pain of the trunk and limbs. However, such implantable electronic devices are vulnerable to external electrical currents and magnetic fields. Within the hospitals and modern operating rooms (ORs), there is an abundance of electrical devices and other types of equipment that could interfere with such devices. Despite the increasing number of patients with neuromodulation implantable devices, there are no written guidelines available or consensus of cautions for such patients undergoing unrelated surgery. CASE DESCRIPTIONS: A 60-year-old female with a permanent St. Jude's spinal cord stimulator (SCS) presented for open total abdominal hysterectomy. Both the anesthesia and gynecology staffs were aware of the device presence, but were unaware of any precautions regarding intraoperative management. The device was found to be nonmagnetic resonance imaging compatible, and bipolar cautery was used instead of monopolar cautery. A 59-year-old female with a 9-year-old permanent Medtronic SCS, presented for right total hip arthroplasty. The device was switched off prior to entering the OR, bipolar cautery was used, and grounding pads were placed away from her battery site. In each case, the manufacturer's representative was contacted preoperative. Both surgeries proceeded uneventfully. CONCLUSIONS: The Food and Drug Administration safety information manual warns about the use of diathermy, concomitant implanted stimulation devices, lithotripsy, external defibrillation, radiation therapy, ultrasonic scanning, and high-output ultrasound, all of which can lead to permanent implant damage if not turned off prior to undertaking procedures. Lack of uniform guidelines makes intraoperative management, as well as remote anesthesia care of patients with previously implanted SCSs unsafe. |
format | Online Article Text |
id | pubmed-4766801 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-47668012016-03-08 Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? Ghaly, Ramsis F. Tverdohleb, Tatiana Candido, Kenneth D. Knezevic, Nebojsa Nick Surg Neurol Int Case Report BACKGROUND: Spinal cord stimulation is currently approved to treat chronic intractable pain of the trunk and limbs. However, such implantable electronic devices are vulnerable to external electrical currents and magnetic fields. Within the hospitals and modern operating rooms (ORs), there is an abundance of electrical devices and other types of equipment that could interfere with such devices. Despite the increasing number of patients with neuromodulation implantable devices, there are no written guidelines available or consensus of cautions for such patients undergoing unrelated surgery. CASE DESCRIPTIONS: A 60-year-old female with a permanent St. Jude's spinal cord stimulator (SCS) presented for open total abdominal hysterectomy. Both the anesthesia and gynecology staffs were aware of the device presence, but were unaware of any precautions regarding intraoperative management. The device was found to be nonmagnetic resonance imaging compatible, and bipolar cautery was used instead of monopolar cautery. A 59-year-old female with a 9-year-old permanent Medtronic SCS, presented for right total hip arthroplasty. The device was switched off prior to entering the OR, bipolar cautery was used, and grounding pads were placed away from her battery site. In each case, the manufacturer's representative was contacted preoperative. Both surgeries proceeded uneventfully. CONCLUSIONS: The Food and Drug Administration safety information manual warns about the use of diathermy, concomitant implanted stimulation devices, lithotripsy, external defibrillation, radiation therapy, ultrasonic scanning, and high-output ultrasound, all of which can lead to permanent implant damage if not turned off prior to undertaking procedures. Lack of uniform guidelines makes intraoperative management, as well as remote anesthesia care of patients with previously implanted SCSs unsafe. Medknow Publications & Media Pvt Ltd 2016-02-15 /pmc/articles/PMC4766801/ /pubmed/26958424 http://dx.doi.org/10.4103/2152-7806.176373 Text en Copyright: © 2016 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Ghaly, Ramsis F. Tverdohleb, Tatiana Candido, Kenneth D. Knezevic, Nebojsa Nick Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title | Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title_full | Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title_fullStr | Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title_full_unstemmed | Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title_short | Do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
title_sort | do we need to establish guidelines for patients with neuromodulation implantable devices, including spinal cord stimulators undergoing nonspinal surgeries? |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4766801/ https://www.ncbi.nlm.nih.gov/pubmed/26958424 http://dx.doi.org/10.4103/2152-7806.176373 |
work_keys_str_mv | AT ghalyramsisf doweneedtoestablishguidelinesforpatientswithneuromodulationimplantabledevicesincludingspinalcordstimulatorsundergoingnonspinalsurgeries AT tverdohlebtatiana doweneedtoestablishguidelinesforpatientswithneuromodulationimplantabledevicesincludingspinalcordstimulatorsundergoingnonspinalsurgeries AT candidokennethd doweneedtoestablishguidelinesforpatientswithneuromodulationimplantabledevicesincludingspinalcordstimulatorsundergoingnonspinalsurgeries AT knezevicnebojsanick doweneedtoestablishguidelinesforpatientswithneuromodulationimplantabledevicesincludingspinalcordstimulatorsundergoingnonspinalsurgeries |