Cargando…

More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses

Signal detection in functional magnetic resonance imaging (fMRI) inherently involves the problem of testing a large number of hypotheses. A popular strategy to address this multiplicity is the control of the false discovery rate (FDR). In this work we consider the case where prior knowledge is avail...

Descripción completa

Detalles Bibliográficos
Autores principales: Schildknecht, Konstantin, Tabelow, Karsten, Dickhaus, Thorsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4767609/
https://www.ncbi.nlm.nih.gov/pubmed/26914144
http://dx.doi.org/10.1371/journal.pone.0149016
_version_ 1782417833784770560
author Schildknecht, Konstantin
Tabelow, Karsten
Dickhaus, Thorsten
author_facet Schildknecht, Konstantin
Tabelow, Karsten
Dickhaus, Thorsten
author_sort Schildknecht, Konstantin
collection PubMed
description Signal detection in functional magnetic resonance imaging (fMRI) inherently involves the problem of testing a large number of hypotheses. A popular strategy to address this multiplicity is the control of the false discovery rate (FDR). In this work we consider the case where prior knowledge is available to partition the set of all hypotheses into disjoint subsets or families, e. g., by a-priori knowledge on the functionality of certain regions of interest. If the proportion of true null hypotheses differs between families, this structural information can be used to increase statistical power. We propose a two-stage multiple test procedure which first excludes those families from the analysis for which there is no strong evidence for containing true alternatives. We show control of the family-wise error rate at this first stage of testing. Then, at the second stage, we proceed to test the hypotheses within each non-excluded family and obtain asymptotic control of the FDR within each family at this second stage. Our main mathematical result is that this two-stage strategy implies asymptotic control of the FDR with respect to all hypotheses. In simulations we demonstrate the increased power of this new procedure in comparison with established procedures in situations with highly unbalanced families. Finally, we apply the proposed method to simulated and to real fMRI data.
format Online
Article
Text
id pubmed-4767609
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47676092016-03-09 More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses Schildknecht, Konstantin Tabelow, Karsten Dickhaus, Thorsten PLoS One Research Article Signal detection in functional magnetic resonance imaging (fMRI) inherently involves the problem of testing a large number of hypotheses. A popular strategy to address this multiplicity is the control of the false discovery rate (FDR). In this work we consider the case where prior knowledge is available to partition the set of all hypotheses into disjoint subsets or families, e. g., by a-priori knowledge on the functionality of certain regions of interest. If the proportion of true null hypotheses differs between families, this structural information can be used to increase statistical power. We propose a two-stage multiple test procedure which first excludes those families from the analysis for which there is no strong evidence for containing true alternatives. We show control of the family-wise error rate at this first stage of testing. Then, at the second stage, we proceed to test the hypotheses within each non-excluded family and obtain asymptotic control of the FDR within each family at this second stage. Our main mathematical result is that this two-stage strategy implies asymptotic control of the FDR with respect to all hypotheses. In simulations we demonstrate the increased power of this new procedure in comparison with established procedures in situations with highly unbalanced families. Finally, we apply the proposed method to simulated and to real fMRI data. Public Library of Science 2016-02-25 /pmc/articles/PMC4767609/ /pubmed/26914144 http://dx.doi.org/10.1371/journal.pone.0149016 Text en © 2016 Schildknecht et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Schildknecht, Konstantin
Tabelow, Karsten
Dickhaus, Thorsten
More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title_full More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title_fullStr More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title_full_unstemmed More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title_short More Specific Signal Detection in Functional Magnetic Resonance Imaging by False Discovery Rate Control for Hierarchically Structured Systems of Hypotheses
title_sort more specific signal detection in functional magnetic resonance imaging by false discovery rate control for hierarchically structured systems of hypotheses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4767609/
https://www.ncbi.nlm.nih.gov/pubmed/26914144
http://dx.doi.org/10.1371/journal.pone.0149016
work_keys_str_mv AT schildknechtkonstantin morespecificsignaldetectioninfunctionalmagneticresonanceimagingbyfalsediscoveryratecontrolforhierarchicallystructuredsystemsofhypotheses
AT tabelowkarsten morespecificsignaldetectioninfunctionalmagneticresonanceimagingbyfalsediscoveryratecontrolforhierarchicallystructuredsystemsofhypotheses
AT dickhausthorsten morespecificsignaldetectioninfunctionalmagneticresonanceimagingbyfalsediscoveryratecontrolforhierarchicallystructuredsystemsofhypotheses