Cargando…

Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes

A miniature X-ray source has been optimized for electronic brachytherapy. The cooling fluid for this device is water. Unlike the radionuclide brachytherapy sources, this source is able to operate at variable voltages and currents to match the dose with the tumor depth. First, Monte Carlo (MC) optimi...

Descripción completa

Detalles Bibliográficos
Autores principales: Khajeh, Masoud, Safigholi, Habib
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4767795/
https://www.ncbi.nlm.nih.gov/pubmed/26966563
http://dx.doi.org/10.1016/j.jare.2015.04.006
_version_ 1782417845387264000
author Khajeh, Masoud
Safigholi, Habib
author_facet Khajeh, Masoud
Safigholi, Habib
author_sort Khajeh, Masoud
collection PubMed
description A miniature X-ray source has been optimized for electronic brachytherapy. The cooling fluid for this device is water. Unlike the radionuclide brachytherapy sources, this source is able to operate at variable voltages and currents to match the dose with the tumor depth. First, Monte Carlo (MC) optimization was performed on the tungsten target-buffer thickness layers versus energy such that the minimum X-ray attenuation occurred. Second optimization was done on the selection of the anode shape based on the Monte Carlo in water TG-43U1 anisotropy function. This optimization was carried out to get the dose anisotropy functions closer to unity at any angle from 0° to 170°. Three anode shapes including cylindrical, spherical, and conical were considered. Moreover, by Computational Fluid Dynamic (CFD) code the optimal target-buffer shape and different nozzle shapes for electronic brachytherapy were evaluated. The characterization criteria of the CFD were the minimum temperature on the anode shape, cooling water, and pressure loss from inlet to outlet. The optimal anode was conical in shape with a conical nozzle. Finally, the TG-43U1 parameters of the optimal source were compared with the literature.
format Online
Article
Text
id pubmed-4767795
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-47677952016-03-10 Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes Khajeh, Masoud Safigholi, Habib J Adv Res Original Article A miniature X-ray source has been optimized for electronic brachytherapy. The cooling fluid for this device is water. Unlike the radionuclide brachytherapy sources, this source is able to operate at variable voltages and currents to match the dose with the tumor depth. First, Monte Carlo (MC) optimization was performed on the tungsten target-buffer thickness layers versus energy such that the minimum X-ray attenuation occurred. Second optimization was done on the selection of the anode shape based on the Monte Carlo in water TG-43U1 anisotropy function. This optimization was carried out to get the dose anisotropy functions closer to unity at any angle from 0° to 170°. Three anode shapes including cylindrical, spherical, and conical were considered. Moreover, by Computational Fluid Dynamic (CFD) code the optimal target-buffer shape and different nozzle shapes for electronic brachytherapy were evaluated. The characterization criteria of the CFD were the minimum temperature on the anode shape, cooling water, and pressure loss from inlet to outlet. The optimal anode was conical in shape with a conical nozzle. Finally, the TG-43U1 parameters of the optimal source were compared with the literature. Elsevier 2016-03 2015-04-20 /pmc/articles/PMC4767795/ /pubmed/26966563 http://dx.doi.org/10.1016/j.jare.2015.04.006 Text en © 2015 Production and hosting by Elsevier B.V. on behalf of Cairo University. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Khajeh, Masoud
Safigholi, Habib
Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title_full Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title_fullStr Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title_full_unstemmed Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title_short Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
title_sort anode optimization for miniature electronic brachytherapy x-ray sources using monte carlo and computational fluid dynamic codes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4767795/
https://www.ncbi.nlm.nih.gov/pubmed/26966563
http://dx.doi.org/10.1016/j.jare.2015.04.006
work_keys_str_mv AT khajehmasoud anodeoptimizationforminiatureelectronicbrachytherapyxraysourcesusingmontecarloandcomputationalfluiddynamiccodes
AT safigholihabib anodeoptimizationforminiatureelectronicbrachytherapyxraysourcesusingmontecarloandcomputationalfluiddynamiccodes