Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging

PURPOSE: Many neurological diseases affect small structures in the brain and, as such, reliable visual evaluation and accurate quantification are required. Recent technological developments made the clinical use of hybrid positron emission tomography/magnetic resonance (PET/MR) systems possible, pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Leemans, Eva L., Kotasidis, Fotis, Wissmeyer, Michael, Garibotto, Valentina, Zaidi, Habib
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768229/
https://www.ncbi.nlm.nih.gov/pubmed/25634260
http://dx.doi.org/10.1007/s11307-015-0824-x
_version_ 1782417913151488000
author Leemans, Eva L.
Kotasidis, Fotis
Wissmeyer, Michael
Garibotto, Valentina
Zaidi, Habib
author_facet Leemans, Eva L.
Kotasidis, Fotis
Wissmeyer, Michael
Garibotto, Valentina
Zaidi, Habib
author_sort Leemans, Eva L.
collection PubMed
description PURPOSE: Many neurological diseases affect small structures in the brain and, as such, reliable visual evaluation and accurate quantification are required. Recent technological developments made the clinical use of hybrid positron emission tomography/magnetic resonance (PET/MR) systems possible, providing both functional and anatomical information in a single imaging session. Nevertheless, there is a trade-off between spatial resolution and image quality (contrast and noise), which is dictated mainly by the chosen acquisition and reconstruction protocols. Image reconstruction algorithms using spherical symmetric basis functions (blobs) for image representation have a number of additional parameters that impact both the qualitative and quantitative image characteristics. Hence, a detailed investigation of the blob-based reconstruction characteristics using different parameters is needed to achieve optimal reconstruction results. PROCEDURES: This work evaluated the impact of a range of blob parameters on image quality and quantitative accuracy of brain PET images acquired on the Ingenuity Time-of-Flight (TOF) PET/MR system. Two different phantoms were used to simulate brain imaging applications. Image contrast and noise characteristics were assessed using an image quality phantom. Quantitative performance in a clinical setting was investigated using the Hoffman 3D brain phantom at various count levels. Furthermore, the visual quality of four clinical studies was scored blindly by two experienced physicians to qualitatively evaluate the influence of different reconstruction protocols, hereby providing indications on parameters producing the best image quality. RESULTS: Quantitative evaluation using the image quality phantom showed that larger basis function radii result in lower contrast recovery (∼2 %) and lower variance levels (∼15 %). The brain phantom and clinical studies confirmed these observations since lower contrast was seen between anatomical structures. High and low count statistics gave comparable values. The qualitative evaluation of the clinical studies, based on the assessment performed by the physicians, showed a preference towards lower image variance levels with a slightly lower contrast, favoring higher radii and four iterations. CONCLUSION: This study systematically evaluated a number of basis function parameters and their quantitative and qualitative effect within PET image reconstruction in the context of brain imaging. A range of blob parameters can minimize error and provided optimal image quality, where the anatomical structures could be recognized but the exact delineation of these structures is simplified in scans with lower image variance levels and thus, higher radii should be preferred. With the optimization of blob parameters, the reconstructed images were found to be qualitatively improved (optimum parameters {d = 2.0375, alpha = 10.4101, radius = 3.9451}) as assessed by the physicians compared to the current clinical protocol. However, this qualitative improvement is task specific, depending on the desired image characteristics to be extracted. Finally, this work could be used as a guide for application-specific optimal parameter selection. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11307-015-0824-x) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4768229
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-47682292016-03-29 Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging Leemans, Eva L. Kotasidis, Fotis Wissmeyer, Michael Garibotto, Valentina Zaidi, Habib Mol Imaging Biol Research Article PURPOSE: Many neurological diseases affect small structures in the brain and, as such, reliable visual evaluation and accurate quantification are required. Recent technological developments made the clinical use of hybrid positron emission tomography/magnetic resonance (PET/MR) systems possible, providing both functional and anatomical information in a single imaging session. Nevertheless, there is a trade-off between spatial resolution and image quality (contrast and noise), which is dictated mainly by the chosen acquisition and reconstruction protocols. Image reconstruction algorithms using spherical symmetric basis functions (blobs) for image representation have a number of additional parameters that impact both the qualitative and quantitative image characteristics. Hence, a detailed investigation of the blob-based reconstruction characteristics using different parameters is needed to achieve optimal reconstruction results. PROCEDURES: This work evaluated the impact of a range of blob parameters on image quality and quantitative accuracy of brain PET images acquired on the Ingenuity Time-of-Flight (TOF) PET/MR system. Two different phantoms were used to simulate brain imaging applications. Image contrast and noise characteristics were assessed using an image quality phantom. Quantitative performance in a clinical setting was investigated using the Hoffman 3D brain phantom at various count levels. Furthermore, the visual quality of four clinical studies was scored blindly by two experienced physicians to qualitatively evaluate the influence of different reconstruction protocols, hereby providing indications on parameters producing the best image quality. RESULTS: Quantitative evaluation using the image quality phantom showed that larger basis function radii result in lower contrast recovery (∼2 %) and lower variance levels (∼15 %). The brain phantom and clinical studies confirmed these observations since lower contrast was seen between anatomical structures. High and low count statistics gave comparable values. The qualitative evaluation of the clinical studies, based on the assessment performed by the physicians, showed a preference towards lower image variance levels with a slightly lower contrast, favoring higher radii and four iterations. CONCLUSION: This study systematically evaluated a number of basis function parameters and their quantitative and qualitative effect within PET image reconstruction in the context of brain imaging. A range of blob parameters can minimize error and provided optimal image quality, where the anatomical structures could be recognized but the exact delineation of these structures is simplified in scans with lower image variance levels and thus, higher radii should be preferred. With the optimization of blob parameters, the reconstructed images were found to be qualitatively improved (optimum parameters {d = 2.0375, alpha = 10.4101, radius = 3.9451}) as assessed by the physicians compared to the current clinical protocol. However, this qualitative improvement is task specific, depending on the desired image characteristics to be extracted. Finally, this work could be used as a guide for application-specific optimal parameter selection. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11307-015-0824-x) contains supplementary material, which is available to authorized users. Springer US 2015-01-30 2015 /pmc/articles/PMC4768229/ /pubmed/25634260 http://dx.doi.org/10.1007/s11307-015-0824-x Text en © The Author(s) 2015 https://creativecommons.org/licenses/by/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Article
Leemans, Eva L.
Kotasidis, Fotis
Wissmeyer, Michael
Garibotto, Valentina
Zaidi, Habib
Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title_full Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title_fullStr Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title_full_unstemmed Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title_short Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging
title_sort qualitative and quantitative evaluation of blob-based time-of-flight pet image reconstruction in hybrid brain pet/mr imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768229/
https://www.ncbi.nlm.nih.gov/pubmed/25634260
http://dx.doi.org/10.1007/s11307-015-0824-x
work_keys_str_mv AT leemanseval qualitativeandquantitativeevaluationofblobbasedtimeofflightpetimagereconstructioninhybridbrainpetmrimaging
AT kotasidisfotis qualitativeandquantitativeevaluationofblobbasedtimeofflightpetimagereconstructioninhybridbrainpetmrimaging
AT wissmeyermichael qualitativeandquantitativeevaluationofblobbasedtimeofflightpetimagereconstructioninhybridbrainpetmrimaging
AT garibottovalentina qualitativeandquantitativeevaluationofblobbasedtimeofflightpetimagereconstructioninhybridbrainpetmrimaging
AT zaidihabib qualitativeandquantitativeevaluationofblobbasedtimeofflightpetimagereconstructioninhybridbrainpetmrimaging