Cargando…

Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity

Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of...

Descripción completa

Detalles Bibliográficos
Autores principales: Harris-Love, Michael O., Seamon, Bryant A., Teixeira, Carla, Ismail, Catheeja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768702/
https://www.ncbi.nlm.nih.gov/pubmed/26925339
http://dx.doi.org/10.7717/peerj.1721
_version_ 1782417992874721280
author Harris-Love, Michael O.
Seamon, Bryant A.
Teixeira, Carla
Ismail, Catheeja
author_facet Harris-Love, Michael O.
Seamon, Bryant A.
Teixeira, Carla
Ismail, Catheeja
author_sort Harris-Love, Michael O.
collection PubMed
description Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R(2)). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R(2) = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults.
format Online
Article
Text
id pubmed-4768702
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-47687022016-02-26 Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity Harris-Love, Michael O. Seamon, Bryant A. Teixeira, Carla Ismail, Catheeja PeerJ Evidence Based Medicine Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R(2)). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R(2) = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults. PeerJ Inc. 2016-02-22 /pmc/articles/PMC4768702/ /pubmed/26925339 http://dx.doi.org/10.7717/peerj.1721 Text en http://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, made available under the Creative Commons Public Domain Dedication (http://creativecommons.org/publicdomain/zero/1.0/) . This work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose.
spellingShingle Evidence Based Medicine
Harris-Love, Michael O.
Seamon, Bryant A.
Teixeira, Carla
Ismail, Catheeja
Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_full Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_fullStr Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_full_unstemmed Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_short Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_sort ultrasound estimates of muscle quality in older adults: reliability and comparison of photoshop and imagej for the grayscale analysis of muscle echogenicity
topic Evidence Based Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768702/
https://www.ncbi.nlm.nih.gov/pubmed/26925339
http://dx.doi.org/10.7717/peerj.1721
work_keys_str_mv AT harrislovemichaelo ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT seamonbryanta ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT teixeiracarla ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT ismailcatheeja ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity