Cargando…
Analysis and control of the photon beam position at PLS-II
At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference phot...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768768/ https://www.ncbi.nlm.nih.gov/pubmed/26917132 http://dx.doi.org/10.1107/S1600577516001338 |
_version_ | 1782417997348995072 |
---|---|
author | Ko, J. Kim, I.-Y. Kim, C. Kim, D.-T. Huang, J.-Y. Shin, S. |
author_facet | Ko, J. Kim, I.-Y. Kim, C. Kim, D.-T. Huang, J.-Y. Shin, S. |
author_sort | Ko, J. |
collection | PubMed |
description | At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data. |
format | Online Article Text |
id | pubmed-4768768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-47687682016-03-02 Analysis and control of the photon beam position at PLS-II Ko, J. Kim, I.-Y. Kim, C. Kim, D.-T. Huang, J.-Y. Shin, S. J Synchrotron Radiat Research Papers At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data. International Union of Crystallography 2016-02-18 /pmc/articles/PMC4768768/ /pubmed/26917132 http://dx.doi.org/10.1107/S1600577516001338 Text en © J. Ko et al. 2016 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Ko, J. Kim, I.-Y. Kim, C. Kim, D.-T. Huang, J.-Y. Shin, S. Analysis and control of the photon beam position at PLS-II |
title | Analysis and control of the photon beam position at PLS-II |
title_full | Analysis and control of the photon beam position at PLS-II |
title_fullStr | Analysis and control of the photon beam position at PLS-II |
title_full_unstemmed | Analysis and control of the photon beam position at PLS-II |
title_short | Analysis and control of the photon beam position at PLS-II |
title_sort | analysis and control of the photon beam position at pls-ii |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768768/ https://www.ncbi.nlm.nih.gov/pubmed/26917132 http://dx.doi.org/10.1107/S1600577516001338 |
work_keys_str_mv | AT koj analysisandcontrolofthephotonbeampositionatplsii AT kimiy analysisandcontrolofthephotonbeampositionatplsii AT kimc analysisandcontrolofthephotonbeampositionatplsii AT kimdt analysisandcontrolofthephotonbeampositionatplsii AT huangjy analysisandcontrolofthephotonbeampositionatplsii AT shins analysisandcontrolofthephotonbeampositionatplsii |