Analysis and control of the photon beam position at PLS-II

At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference phot...

Descripción completa

Detalles Bibliográficos
Autores principales: Ko, J., Kim, I.-Y., Kim, C., Kim, D.-T., Huang, J.-Y., Shin, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768768/
https://www.ncbi.nlm.nih.gov/pubmed/26917132
http://dx.doi.org/10.1107/S1600577516001338
_version_ 1782417997348995072
author Ko, J.
Kim, I.-Y.
Kim, C.
Kim, D.-T.
Huang, J.-Y.
Shin, S.
author_facet Ko, J.
Kim, I.-Y.
Kim, C.
Kim, D.-T.
Huang, J.-Y.
Shin, S.
author_sort Ko, J.
collection PubMed
description At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data.
format Online
Article
Text
id pubmed-4768768
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-47687682016-03-02 Analysis and control of the photon beam position at PLS-II Ko, J. Kim, I.-Y. Kim, C. Kim, D.-T. Huang, J.-Y. Shin, S. J Synchrotron Radiat Research Papers At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r.m.s. was achieved for a user service period in the beamline, where the photon beam position monitor is installed. Nevertheless, a detailed analysis of the photon beam position data was necessary in order to ensure the performance of the photon beam position monitor, since it can suffer from various unknown types of noise, such as background contamination due to upstream or downstream dipole radiation, and undulator gap dependence. This paper reports the results of a start-to-end study of the photon beam position stability and a singular value decomposition analysis to confirm the reliability of the photon beam position data. International Union of Crystallography 2016-02-18 /pmc/articles/PMC4768768/ /pubmed/26917132 http://dx.doi.org/10.1107/S1600577516001338 Text en © J. Ko et al. 2016 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Ko, J.
Kim, I.-Y.
Kim, C.
Kim, D.-T.
Huang, J.-Y.
Shin, S.
Analysis and control of the photon beam position at PLS-II
title Analysis and control of the photon beam position at PLS-II
title_full Analysis and control of the photon beam position at PLS-II
title_fullStr Analysis and control of the photon beam position at PLS-II
title_full_unstemmed Analysis and control of the photon beam position at PLS-II
title_short Analysis and control of the photon beam position at PLS-II
title_sort analysis and control of the photon beam position at pls-ii
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4768768/
https://www.ncbi.nlm.nih.gov/pubmed/26917132
http://dx.doi.org/10.1107/S1600577516001338
work_keys_str_mv AT koj analysisandcontrolofthephotonbeampositionatplsii
AT kimiy analysisandcontrolofthephotonbeampositionatplsii
AT kimc analysisandcontrolofthephotonbeampositionatplsii
AT kimdt analysisandcontrolofthephotonbeampositionatplsii
AT huangjy analysisandcontrolofthephotonbeampositionatplsii
AT shins analysisandcontrolofthephotonbeampositionatplsii