Cargando…

Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy

BACKGROUND: Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-d...

Descripción completa

Detalles Bibliográficos
Autores principales: Rault, Erwann, Lacornerie, Thomas, Dang, Hong-Phuong, Crop, Frederik, Lartigau, Eric, Reynaert, Nick, Pasquier, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769549/
https://www.ncbi.nlm.nih.gov/pubmed/26919837
http://dx.doi.org/10.1186/s13014-016-0607-9
_version_ 1782418121838034944
author Rault, Erwann
Lacornerie, Thomas
Dang, Hong-Phuong
Crop, Frederik
Lartigau, Eric
Reynaert, Nick
Pasquier, David
author_facet Rault, Erwann
Lacornerie, Thomas
Dang, Hong-Phuong
Crop, Frederik
Lartigau, Eric
Reynaert, Nick
Pasquier, David
author_sort Rault, Erwann
collection PubMed
description BACKGROUND: Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). METHODS: The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. RESULTS: Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV coverage and the sparing of the lung and heart. However, the CK may be used to reduce high doses received by the NTBTV more efficiently. CONCLUSIONS: Robotic stereotactic radiotherapy may be used for APBI to more efficiently spare the NTBTV and improve cosmetic results of APBI.
format Online
Article
Text
id pubmed-4769549
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47695492016-02-28 Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy Rault, Erwann Lacornerie, Thomas Dang, Hong-Phuong Crop, Frederik Lartigau, Eric Reynaert, Nick Pasquier, David Radiat Oncol Research BACKGROUND: Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). METHODS: The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. RESULTS: Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV coverage and the sparing of the lung and heart. However, the CK may be used to reduce high doses received by the NTBTV more efficiently. CONCLUSIONS: Robotic stereotactic radiotherapy may be used for APBI to more efficiently spare the NTBTV and improve cosmetic results of APBI. BioMed Central 2016-02-27 /pmc/articles/PMC4769549/ /pubmed/26919837 http://dx.doi.org/10.1186/s13014-016-0607-9 Text en © Rault et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Rault, Erwann
Lacornerie, Thomas
Dang, Hong-Phuong
Crop, Frederik
Lartigau, Eric
Reynaert, Nick
Pasquier, David
Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title_full Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title_fullStr Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title_full_unstemmed Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title_short Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
title_sort accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769549/
https://www.ncbi.nlm.nih.gov/pubmed/26919837
http://dx.doi.org/10.1186/s13014-016-0607-9
work_keys_str_mv AT raulterwann acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT lacorneriethomas acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT danghongphuong acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT cropfrederik acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT lartigaueric acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT reynaertnick acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy
AT pasquierdavid acceleratedpartialbreastirradiationusingroboticradiotherapyadosimetriccomparisonwithtomotherapyandthreedimensionalconformalradiotherapy