Cargando…

Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases

BACKGROUND: Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes...

Descripción completa

Detalles Bibliográficos
Autores principales: Ricciardi, Benjamin F., Nocon, Allina A., Jerabek, Seth A., Wilner, Gabrielle, Kaplowitz, Elianna, Goldring, Steven R., Purdue, P. Edward, Perino, Giorgio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769839/
https://www.ncbi.nlm.nih.gov/pubmed/26924942
http://dx.doi.org/10.1186/s12907-016-0025-9
_version_ 1782418166681436160
author Ricciardi, Benjamin F.
Nocon, Allina A.
Jerabek, Seth A.
Wilner, Gabrielle
Kaplowitz, Elianna
Goldring, Steven R.
Purdue, P. Edward
Perino, Giorgio
author_facet Ricciardi, Benjamin F.
Nocon, Allina A.
Jerabek, Seth A.
Wilner, Gabrielle
Kaplowitz, Elianna
Goldring, Steven R.
Purdue, P. Edward
Perino, Giorgio
author_sort Ricciardi, Benjamin F.
collection PubMed
description BACKGROUND: Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. METHODS: Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. RESULTS: Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. CONCLUSIONS: ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.
format Online
Article
Text
id pubmed-4769839
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47698392016-02-29 Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases Ricciardi, Benjamin F. Nocon, Allina A. Jerabek, Seth A. Wilner, Gabrielle Kaplowitz, Elianna Goldring, Steven R. Purdue, P. Edward Perino, Giorgio BMC Clin Pathol Research Article BACKGROUND: Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. METHODS: Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. RESULTS: Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. CONCLUSIONS: ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation. BioMed Central 2016-02-27 /pmc/articles/PMC4769839/ /pubmed/26924942 http://dx.doi.org/10.1186/s12907-016-0025-9 Text en © Ricciardi et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ricciardi, Benjamin F.
Nocon, Allina A.
Jerabek, Seth A.
Wilner, Gabrielle
Kaplowitz, Elianna
Goldring, Steven R.
Purdue, P. Edward
Perino, Giorgio
Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title_full Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title_fullStr Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title_full_unstemmed Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title_short Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
title_sort histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769839/
https://www.ncbi.nlm.nih.gov/pubmed/26924942
http://dx.doi.org/10.1186/s12907-016-0025-9
work_keys_str_mv AT ricciardibenjaminf histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT noconallinaa histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT jerabeksetha histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT wilnergabrielle histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT kaplowitzelianna histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT goldringstevenr histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT purduepedward histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases
AT perinogiorgio histopathologicalcharacterizationofcorrosionproductassociatedadverselocaltissuereactioninhipimplantsastudyof285cases