Cargando…

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

PURPOSE: Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differe...

Descripción completa

Detalles Bibliográficos
Autores principales: Özarslan, Mehmet Mustafa, Büyükkaplan, Ulviye Şebnem, Barutcigil, Çağatay, Arslan, Merve, Türker, Nurullah, Barutcigil, Kubilay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769885/
https://www.ncbi.nlm.nih.gov/pubmed/26949483
http://dx.doi.org/10.4047/jap.2016.8.1.16
_version_ 1782418172129837056
author Özarslan, Mehmet Mustafa
Büyükkaplan, Ulviye Şebnem
Barutcigil, Çağatay
Arslan, Merve
Türker, Nurullah
Barutcigil, Kubilay
author_facet Özarslan, Mehmet Mustafa
Büyükkaplan, Ulviye Şebnem
Barutcigil, Çağatay
Arslan, Merve
Türker, Nurullah
Barutcigil, Kubilay
author_sort Özarslan, Mehmet Mustafa
collection PubMed
description PURPOSE: Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS: 120 specimens were prepared in dimensions 2 × 10 × 12 mm from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at α=0.05. RESULTS: The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ΔE(00) was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (ΔE(00)<2.25) except Clinical Kit Groups (ΔE(00)>2.25). CONCLUSION: Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.
format Online
Article
Text
id pubmed-4769885
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-47698852016-03-06 Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material Özarslan, Mehmet Mustafa Büyükkaplan, Ulviye Şebnem Barutcigil, Çağatay Arslan, Merve Türker, Nurullah Barutcigil, Kubilay J Adv Prosthodont Original Article PURPOSE: Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS: 120 specimens were prepared in dimensions 2 × 10 × 12 mm from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at α=0.05. RESULTS: The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ΔE(00) was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (ΔE(00)<2.25) except Clinical Kit Groups (ΔE(00)>2.25). CONCLUSION: Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching. The Korean Academy of Prosthodontics 2016-02 2016-02-23 /pmc/articles/PMC4769885/ /pubmed/26949483 http://dx.doi.org/10.4047/jap.2016.8.1.16 Text en © 2016 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Özarslan, Mehmet Mustafa
Büyükkaplan, Ulviye Şebnem
Barutcigil, Çağatay
Arslan, Merve
Türker, Nurullah
Barutcigil, Kubilay
Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title_full Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title_fullStr Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title_full_unstemmed Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title_short Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
title_sort effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4769885/
https://www.ncbi.nlm.nih.gov/pubmed/26949483
http://dx.doi.org/10.4047/jap.2016.8.1.16
work_keys_str_mv AT ozarslanmehmetmustafa effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial
AT buyukkaplanulviyesebnem effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial
AT barutcigilcagatay effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial
AT arslanmerve effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial
AT turkernurullah effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial
AT barutcigilkubilay effectsofdifferentsurfacefinishingproceduresonthechangeinsurfaceroughnessandcolorofapolymerinfiltratedceramicnetworkmaterial