A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component

There has been continued interest in clinical objective measures of binaural processing. One commonly proposed measure is the binaural interaction component (BIC), which is obtained typically by recording auditory brainstem responses (ABRs)—the BIC reflects the difference between the binaural ABR an...

Descripción completa

Detalles Bibliográficos
Autores principales: Haywood, Nicholas R., Undurraga, Jaime A., Marquardt, Torsten, McAlpine, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771038/
https://www.ncbi.nlm.nih.gov/pubmed/26721925
http://dx.doi.org/10.1177/2331216515619039
_version_ 1782418357114372096
author Haywood, Nicholas R.
Undurraga, Jaime A.
Marquardt, Torsten
McAlpine, David
author_facet Haywood, Nicholas R.
Undurraga, Jaime A.
Marquardt, Torsten
McAlpine, David
author_sort Haywood, Nicholas R.
collection PubMed
description There has been continued interest in clinical objective measures of binaural processing. One commonly proposed measure is the binaural interaction component (BIC), which is obtained typically by recording auditory brainstem responses (ABRs)—the BIC reflects the difference between the binaural ABR and the sum of the monaural ABRs (i.e., binaural − (left + right)). We have recently developed an alternative, direct measure of sensitivity to interaural time differences, namely, a following response to modulations in interaural phase difference (the interaural phase modulation following response; IPM-FR). To obtain this measure, an ongoing diotically amplitude-modulated signal is presented, and the interaural phase difference of the carrier is switched periodically at minima in the modulation cycle. Such periodic modulations to interaural phase difference can evoke a steady state following response. BIC and IPM-FR measurements were compared from 10 normal-hearing subjects using a 16-channel electroencephalographic system. Both ABRs and IPM-FRs were observed most clearly from similar electrode locations—differential recordings taken from electrodes near the ear (e.g., mastoid) in reference to a vertex electrode (Cz). Although all subjects displayed clear ABRs, the BIC was not reliably observed. In contrast, the IPM-FR typically elicited a robust and significant response. In addition, the IPM-FR measure required a considerably shorter recording session. As the IPM-FR magnitude varied with interaural phase difference modulation depth, it could potentially serve as a correlate of perceptual salience. Overall, the IPM-FR appears a more suitable clinical measure than the BIC.
format Online
Article
Text
id pubmed-4771038
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-47710382016-05-26 A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component Haywood, Nicholas R. Undurraga, Jaime A. Marquardt, Torsten McAlpine, David Trends Hear Special Issue There has been continued interest in clinical objective measures of binaural processing. One commonly proposed measure is the binaural interaction component (BIC), which is obtained typically by recording auditory brainstem responses (ABRs)—the BIC reflects the difference between the binaural ABR and the sum of the monaural ABRs (i.e., binaural − (left + right)). We have recently developed an alternative, direct measure of sensitivity to interaural time differences, namely, a following response to modulations in interaural phase difference (the interaural phase modulation following response; IPM-FR). To obtain this measure, an ongoing diotically amplitude-modulated signal is presented, and the interaural phase difference of the carrier is switched periodically at minima in the modulation cycle. Such periodic modulations to interaural phase difference can evoke a steady state following response. BIC and IPM-FR measurements were compared from 10 normal-hearing subjects using a 16-channel electroencephalographic system. Both ABRs and IPM-FRs were observed most clearly from similar electrode locations—differential recordings taken from electrodes near the ear (e.g., mastoid) in reference to a vertex electrode (Cz). Although all subjects displayed clear ABRs, the BIC was not reliably observed. In contrast, the IPM-FR typically elicited a robust and significant response. In addition, the IPM-FR measure required a considerably shorter recording session. As the IPM-FR magnitude varied with interaural phase difference modulation depth, it could potentially serve as a correlate of perceptual salience. Overall, the IPM-FR appears a more suitable clinical measure than the BIC. SAGE Publications 2015-12-29 /pmc/articles/PMC4771038/ /pubmed/26721925 http://dx.doi.org/10.1177/2331216515619039 Text en © The Author(s) 2015 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Special Issue
Haywood, Nicholas R.
Undurraga, Jaime A.
Marquardt, Torsten
McAlpine, David
A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title_full A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title_fullStr A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title_full_unstemmed A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title_short A Comparison of Two Objective Measures of Binaural Processing: The Interaural Phase Modulation Following Response and the Binaural Interaction Component
title_sort comparison of two objective measures of binaural processing: the interaural phase modulation following response and the binaural interaction component
topic Special Issue
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771038/
https://www.ncbi.nlm.nih.gov/pubmed/26721925
http://dx.doi.org/10.1177/2331216515619039
work_keys_str_mv AT haywoodnicholasr acomparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT undurragajaimea acomparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT marquardttorsten acomparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT mcalpinedavid acomparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT haywoodnicholasr comparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT undurragajaimea comparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT marquardttorsten comparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent
AT mcalpinedavid comparisonoftwoobjectivemeasuresofbinauralprocessingtheinterauralphasemodulationfollowingresponseandthebinauralinteractioncomponent