Cargando…

Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute

PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes...

Descripción completa

Detalles Bibliográficos
Autores principales: Abulon, Dina Joy K., Buboltz, David C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771069/
https://www.ncbi.nlm.nih.gov/pubmed/26933520
http://dx.doi.org/10.1167/tvst.5.1.7
_version_ 1782418361816186880
author Abulon, Dina Joy K.
Buboltz, David C.
author_facet Abulon, Dina Joy K.
Buboltz, David C.
author_sort Abulon, Dina Joy K.
collection PubMed
description PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27(+)-, 25(+)-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by LabVIEW software that converted real-time mass measurements from an electronic scale into flow rate. RESULTS: Average vitreous flow rate increased slightly with increased cut rate in all probes with 50/50 duty cycle; more dramatic flow rate increases were observed for all probes with biased closed duty cycle. Under both conditions, maximum flow rate was observed at 7500 cpm for all gauges. Under the biased open duty cycle, average flow rate was inversely associated with cut rate. CONCLUSION: High-speed cut rate improved efficiency of vitreous aspiration. TRANSLATIONAL RELEVANCE: Increased vitreous aspiration of dual-pneumatic, high-speed vitrectomy probes may improve the efficiency of current vitrectomy techniques, allowing surgeons to take advantage of the benefits of high cut rates without sacrificing flow rate.
format Online
Article
Text
id pubmed-4771069
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-47710692016-03-01 Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute Abulon, Dina Joy K. Buboltz, David C. Transl Vis Sci Technol Articles PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27(+)-, 25(+)-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by LabVIEW software that converted real-time mass measurements from an electronic scale into flow rate. RESULTS: Average vitreous flow rate increased slightly with increased cut rate in all probes with 50/50 duty cycle; more dramatic flow rate increases were observed for all probes with biased closed duty cycle. Under both conditions, maximum flow rate was observed at 7500 cpm for all gauges. Under the biased open duty cycle, average flow rate was inversely associated with cut rate. CONCLUSION: High-speed cut rate improved efficiency of vitreous aspiration. TRANSLATIONAL RELEVANCE: Increased vitreous aspiration of dual-pneumatic, high-speed vitrectomy probes may improve the efficiency of current vitrectomy techniques, allowing surgeons to take advantage of the benefits of high cut rates without sacrificing flow rate. The Association for Research in Vision and Ophthalmology 2016-02-22 /pmc/articles/PMC4771069/ /pubmed/26933520 http://dx.doi.org/10.1167/tvst.5.1.7 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Abulon, Dina Joy K.
Buboltz, David C.
Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title_full Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title_fullStr Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title_full_unstemmed Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title_short Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
title_sort porcine vitreous flow behavior during high-speed vitrectomy up to 7500 cuts per minute
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771069/
https://www.ncbi.nlm.nih.gov/pubmed/26933520
http://dx.doi.org/10.1167/tvst.5.1.7
work_keys_str_mv AT abulondinajoyk porcinevitreousflowbehaviorduringhighspeedvitrectomyupto7500cutsperminute
AT buboltzdavidc porcinevitreousflowbehaviorduringhighspeedvitrectomyupto7500cutsperminute