Cargando…
Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771069/ https://www.ncbi.nlm.nih.gov/pubmed/26933520 http://dx.doi.org/10.1167/tvst.5.1.7 |
_version_ | 1782418361816186880 |
---|---|
author | Abulon, Dina Joy K. Buboltz, David C. |
author_facet | Abulon, Dina Joy K. Buboltz, David C. |
author_sort | Abulon, Dina Joy K. |
collection | PubMed |
description | PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27(+)-, 25(+)-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by LabVIEW software that converted real-time mass measurements from an electronic scale into flow rate. RESULTS: Average vitreous flow rate increased slightly with increased cut rate in all probes with 50/50 duty cycle; more dramatic flow rate increases were observed for all probes with biased closed duty cycle. Under both conditions, maximum flow rate was observed at 7500 cpm for all gauges. Under the biased open duty cycle, average flow rate was inversely associated with cut rate. CONCLUSION: High-speed cut rate improved efficiency of vitreous aspiration. TRANSLATIONAL RELEVANCE: Increased vitreous aspiration of dual-pneumatic, high-speed vitrectomy probes may improve the efficiency of current vitrectomy techniques, allowing surgeons to take advantage of the benefits of high cut rates without sacrificing flow rate. |
format | Online Article Text |
id | pubmed-4771069 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-47710692016-03-01 Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute Abulon, Dina Joy K. Buboltz, David C. Transl Vis Sci Technol Articles PURPOSE: To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS: An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27(+)-, 25(+)-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by LabVIEW software that converted real-time mass measurements from an electronic scale into flow rate. RESULTS: Average vitreous flow rate increased slightly with increased cut rate in all probes with 50/50 duty cycle; more dramatic flow rate increases were observed for all probes with biased closed duty cycle. Under both conditions, maximum flow rate was observed at 7500 cpm for all gauges. Under the biased open duty cycle, average flow rate was inversely associated with cut rate. CONCLUSION: High-speed cut rate improved efficiency of vitreous aspiration. TRANSLATIONAL RELEVANCE: Increased vitreous aspiration of dual-pneumatic, high-speed vitrectomy probes may improve the efficiency of current vitrectomy techniques, allowing surgeons to take advantage of the benefits of high cut rates without sacrificing flow rate. The Association for Research in Vision and Ophthalmology 2016-02-22 /pmc/articles/PMC4771069/ /pubmed/26933520 http://dx.doi.org/10.1167/tvst.5.1.7 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Articles Abulon, Dina Joy K. Buboltz, David C. Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title | Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title_full | Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title_fullStr | Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title_full_unstemmed | Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title_short | Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute |
title_sort | porcine vitreous flow behavior during high-speed vitrectomy up to 7500 cuts per minute |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771069/ https://www.ncbi.nlm.nih.gov/pubmed/26933520 http://dx.doi.org/10.1167/tvst.5.1.7 |
work_keys_str_mv | AT abulondinajoyk porcinevitreousflowbehaviorduringhighspeedvitrectomyupto7500cutsperminute AT buboltzdavidc porcinevitreousflowbehaviorduringhighspeedvitrectomyupto7500cutsperminute |