Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy

PURPOSE: To characterize the effects of intraframe distortion due to involuntary eye motion on measures of cone mosaic geometry derived from adaptive optics scanning light ophthalmoscope (AOSLO) images. METHODS: We acquired AOSLO image sequences from 20 subjects at 1.0, 2.0, and 5.0° temporal from f...

Descripción completa

Detalles Bibliográficos
Autores principales: Cooper, Robert F., Sulai, Yusufu N., Dubis, Adam M., Chui, Toco Y., Rosen, Richard B., Michaelides, Michel, Dubra, Alfredo, Carroll, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771077/
https://www.ncbi.nlm.nih.gov/pubmed/26933523
http://dx.doi.org/10.1167/tvst.5.1.10
_version_ 1782418362503004160
author Cooper, Robert F.
Sulai, Yusufu N.
Dubis, Adam M.
Chui, Toco Y.
Rosen, Richard B.
Michaelides, Michel
Dubra, Alfredo
Carroll, Joseph
author_facet Cooper, Robert F.
Sulai, Yusufu N.
Dubis, Adam M.
Chui, Toco Y.
Rosen, Richard B.
Michaelides, Michel
Dubra, Alfredo
Carroll, Joseph
author_sort Cooper, Robert F.
collection PubMed
description PURPOSE: To characterize the effects of intraframe distortion due to involuntary eye motion on measures of cone mosaic geometry derived from adaptive optics scanning light ophthalmoscope (AOSLO) images. METHODS: We acquired AOSLO image sequences from 20 subjects at 1.0, 2.0, and 5.0° temporal from fixation. An expert grader manually selected 10 minimally distorted reference frames from each 150-frame sequence for subsequent registration. Cone mosaic geometry was measured in all registered images (n = 600) using multiple metrics, and the repeatability of these metrics was used to assess the impact of the distortions from each reference frame. In nine additional subjects, we compared AOSLO-derived measurements to those from adaptive optics (AO)-fundus images, which do not contain system-imposed intraframe distortions. RESULTS: We observed substantial variation across subjects in the repeatability of density (1.2%–8.7%), inter-cell distance (0.8%–4.6%), percentage of six-sided Voronoi cells (0.8%–10.6%), and Voronoi cell area regularity (VCAR) (1.2%–13.2%). The average of all metrics extracted from AOSLO images (with the exception of VCAR) was not significantly different than those derived from AO-fundus images, though there was variability between individual images. CONCLUSIONS: Our data demonstrate that the intraframe distortion found in AOSLO images can affect the accuracy and repeatability of cone mosaic metrics. It may be possible to use multiple images from the same retinal area to approximate a “distortionless” image, though more work is needed to evaluate the feasibility of this approach. TRANSLATIONAL RELEVANCE: Even in subjects with good fixation, images from AOSLOs contain intraframe distortions due to eye motion during scanning. The existence of these artifacts emphasizes the need for caution when interpreting results derived from scanning instruments.
format Online
Article
Text
id pubmed-4771077
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-47710772016-03-01 Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy Cooper, Robert F. Sulai, Yusufu N. Dubis, Adam M. Chui, Toco Y. Rosen, Richard B. Michaelides, Michel Dubra, Alfredo Carroll, Joseph Transl Vis Sci Technol Articles PURPOSE: To characterize the effects of intraframe distortion due to involuntary eye motion on measures of cone mosaic geometry derived from adaptive optics scanning light ophthalmoscope (AOSLO) images. METHODS: We acquired AOSLO image sequences from 20 subjects at 1.0, 2.0, and 5.0° temporal from fixation. An expert grader manually selected 10 minimally distorted reference frames from each 150-frame sequence for subsequent registration. Cone mosaic geometry was measured in all registered images (n = 600) using multiple metrics, and the repeatability of these metrics was used to assess the impact of the distortions from each reference frame. In nine additional subjects, we compared AOSLO-derived measurements to those from adaptive optics (AO)-fundus images, which do not contain system-imposed intraframe distortions. RESULTS: We observed substantial variation across subjects in the repeatability of density (1.2%–8.7%), inter-cell distance (0.8%–4.6%), percentage of six-sided Voronoi cells (0.8%–10.6%), and Voronoi cell area regularity (VCAR) (1.2%–13.2%). The average of all metrics extracted from AOSLO images (with the exception of VCAR) was not significantly different than those derived from AO-fundus images, though there was variability between individual images. CONCLUSIONS: Our data demonstrate that the intraframe distortion found in AOSLO images can affect the accuracy and repeatability of cone mosaic metrics. It may be possible to use multiple images from the same retinal area to approximate a “distortionless” image, though more work is needed to evaluate the feasibility of this approach. TRANSLATIONAL RELEVANCE: Even in subjects with good fixation, images from AOSLOs contain intraframe distortions due to eye motion during scanning. The existence of these artifacts emphasizes the need for caution when interpreting results derived from scanning instruments. The Association for Research in Vision and Ophthalmology 2016-02-22 /pmc/articles/PMC4771077/ /pubmed/26933523 http://dx.doi.org/10.1167/tvst.5.1.10 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Cooper, Robert F.
Sulai, Yusufu N.
Dubis, Adam M.
Chui, Toco Y.
Rosen, Richard B.
Michaelides, Michel
Dubra, Alfredo
Carroll, Joseph
Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title_full Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title_fullStr Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title_full_unstemmed Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title_short Effects of Intraframe Distortion on Measures of Cone Mosaic Geometry from Adaptive Optics Scanning Light Ophthalmoscopy
title_sort effects of intraframe distortion on measures of cone mosaic geometry from adaptive optics scanning light ophthalmoscopy
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771077/
https://www.ncbi.nlm.nih.gov/pubmed/26933523
http://dx.doi.org/10.1167/tvst.5.1.10
work_keys_str_mv AT cooperrobertf effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT sulaiyusufun effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT dubisadamm effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT chuitocoy effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT rosenrichardb effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT michaelidesmichel effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT dubraalfredo effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy
AT carrolljoseph effectsofintraframedistortiononmeasuresofconemosaicgeometryfromadaptiveopticsscanninglightophthalmoscopy