Cargando…

The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker

BACKGROUND: Patients eligible for cardiac resynchronisation therapy (CRT) have an indication for primary prophylactic implantable cardioverter defibrillator (ICD) therapy. However, response to CRT might influence processes involved in arrhythmogenesis and therefore change the necessity of ICD therap...

Descripción completa

Detalles Bibliográficos
Autores principales: ter Horst, I. A. H., van ’t Sant, J., Wijers, S. C., Vos, M. A., Cramer, M. J., Meine, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bohn Stafleu van Loghum 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771627/
https://www.ncbi.nlm.nih.gov/pubmed/26797979
http://dx.doi.org/10.1007/s12471-015-0800-8
_version_ 1782418410853892096
author ter Horst, I. A. H.
van ’t Sant, J.
Wijers, S. C.
Vos, M. A.
Cramer, M. J.
Meine, M.
author_facet ter Horst, I. A. H.
van ’t Sant, J.
Wijers, S. C.
Vos, M. A.
Cramer, M. J.
Meine, M.
author_sort ter Horst, I. A. H.
collection PubMed
description BACKGROUND: Patients eligible for cardiac resynchronisation therapy (CRT) have an indication for primary prophylactic implantable cardioverter defibrillator (ICD) therapy. However, response to CRT might influence processes involved in arrhythmogenesis and therefore change the necessity of ICD therapy in certain patients. METHOD: In 202 CRT-defibrillator patients, the association between baseline variables, 6-month echocardiographic outcome (volume response: left ventricular end-systolic volume decrease < ≥15 % and left ventricular ejection fraction (LVEF) ≤ >35 %) and the risk of first appropriate ICD therapy was analysed retrospectively. RESULTS: Fifty (25 %) patients received appropriate ICD therapy during a median follow-up of 37 (23–52) months. At baseline ischaemic cardiomyopathy (hazard ratio (HR) 2.0, p = 0.019) and a B-type natriuretic peptide level > 163 pmol/l (HR 3.8, p < 0.001) were significantly associated with the risk of appropriate ICD therapy. After 6 months, 105 (52 %) patients showed volume response and 51 (25 %) reached an LVEF > 35 %. Three (6 %) patients with an LVEF > 35 % received appropriate ICD therapy following echocardiography at ± 6 months compared with 43 patients (29 %) with an LVEF ≤ 35 % (p = 0.001). LVEF post-CRT was more strongly associated to the risk of ventricular arrhythmias than volume response (LVEF > 35 %, HR 0.23, p = 0.020). CONCLUSION: Assessing the necessity of an ICD in patients eligible for CRT remains a challenge. Six months post-CRT an LVEF > 35 % identified patients at low risk of ventricular arrhythmias. LVEF might be used at the time of generator replacement to identify patients suitable for downgrading to a CRT-pacemaker.
format Online
Article
Text
id pubmed-4771627
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Bohn Stafleu van Loghum
record_format MEDLINE/PubMed
spelling pubmed-47716272016-03-22 The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker ter Horst, I. A. H. van ’t Sant, J. Wijers, S. C. Vos, M. A. Cramer, M. J. Meine, M. Neth Heart J Original Article BACKGROUND: Patients eligible for cardiac resynchronisation therapy (CRT) have an indication for primary prophylactic implantable cardioverter defibrillator (ICD) therapy. However, response to CRT might influence processes involved in arrhythmogenesis and therefore change the necessity of ICD therapy in certain patients. METHOD: In 202 CRT-defibrillator patients, the association between baseline variables, 6-month echocardiographic outcome (volume response: left ventricular end-systolic volume decrease < ≥15 % and left ventricular ejection fraction (LVEF) ≤ >35 %) and the risk of first appropriate ICD therapy was analysed retrospectively. RESULTS: Fifty (25 %) patients received appropriate ICD therapy during a median follow-up of 37 (23–52) months. At baseline ischaemic cardiomyopathy (hazard ratio (HR) 2.0, p = 0.019) and a B-type natriuretic peptide level > 163 pmol/l (HR 3.8, p < 0.001) were significantly associated with the risk of appropriate ICD therapy. After 6 months, 105 (52 %) patients showed volume response and 51 (25 %) reached an LVEF > 35 %. Three (6 %) patients with an LVEF > 35 % received appropriate ICD therapy following echocardiography at ± 6 months compared with 43 patients (29 %) with an LVEF ≤ 35 % (p = 0.001). LVEF post-CRT was more strongly associated to the risk of ventricular arrhythmias than volume response (LVEF > 35 %, HR 0.23, p = 0.020). CONCLUSION: Assessing the necessity of an ICD in patients eligible for CRT remains a challenge. Six months post-CRT an LVEF > 35 % identified patients at low risk of ventricular arrhythmias. LVEF might be used at the time of generator replacement to identify patients suitable for downgrading to a CRT-pacemaker. Bohn Stafleu van Loghum 2016-01-21 2016-03 /pmc/articles/PMC4771627/ /pubmed/26797979 http://dx.doi.org/10.1007/s12471-015-0800-8 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
ter Horst, I. A. H.
van ’t Sant, J.
Wijers, S. C.
Vos, M. A.
Cramer, M. J.
Meine, M.
The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title_full The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title_fullStr The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title_full_unstemmed The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title_short The risk of ventricular arrhythmias in a Dutch CRT population: CRT-defibrillator versus CRT-pacemaker
title_sort risk of ventricular arrhythmias in a dutch crt population: crt-defibrillator versus crt-pacemaker
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4771627/
https://www.ncbi.nlm.nih.gov/pubmed/26797979
http://dx.doi.org/10.1007/s12471-015-0800-8
work_keys_str_mv AT terhorstiah theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT vantsantj theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT wijerssc theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT vosma theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT cramermj theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT meinem theriskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT terhorstiah riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT vantsantj riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT wijerssc riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT vosma riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT cramermj riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker
AT meinem riskofventriculararrhythmiasinadutchcrtpopulationcrtdefibrillatorversuscrtpacemaker