Cargando…
Spatial Variations in Vitreous Oxygen Consumption
We investigated the spatial variation of vitreous oxygen consumption in enucleated porcine eyes. A custom made oxygen source was fabricated that could be localized to either the mid or posterior vitreous cavity and steady state vitreous oxygen tension was measured as a function of distance from the...
Autores principales: | Murali, Karthik, Kang, Dongyang, Nazari, Hossein, Scianmarello, Nicholas, Cadenas, Enrique, Tai, Yu-Chong, Kashani, Amir, Humayun, Mark |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4773158/ https://www.ncbi.nlm.nih.gov/pubmed/26930281 http://dx.doi.org/10.1371/journal.pone.0149961 |