Cargando…
Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing
In situ, cells of the musculoskeletal system reside within complex and often interconnected 3-D environments. Key to better understanding how 3-D tissue and cellular environments regulate musculoskeletal physiology, homeostasis, and health is the use of robust methodologies for directly visualizing...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4773178/ https://www.ncbi.nlm.nih.gov/pubmed/26930293 http://dx.doi.org/10.1371/journal.pone.0150268 |
_version_ | 1782418690390622208 |
---|---|
author | Berke, Ian M. Miola, Joseph P. David, Michael A. Smith, Melanie K. Price, Christopher |
author_facet | Berke, Ian M. Miola, Joseph P. David, Michael A. Smith, Melanie K. Price, Christopher |
author_sort | Berke, Ian M. |
collection | PubMed |
description | In situ, cells of the musculoskeletal system reside within complex and often interconnected 3-D environments. Key to better understanding how 3-D tissue and cellular environments regulate musculoskeletal physiology, homeostasis, and health is the use of robust methodologies for directly visualizing cell-cell and cell-matrix architecture in situ. However, the use of standard optical imaging techniques is often of limited utility in deep imaging of intact musculoskeletal tissues due to the highly scattering nature of biological tissues. Drawing inspiration from recent developments in the deep-tissue imaging field, we describe the application of immersion based optical clearing techniques, which utilize the principle of refractive index (RI) matching between the clearing/mounting media and tissue under observation, to improve the deep, in situ imaging of musculoskeletal tissues. To date, few optical clearing techniques have been applied specifically to musculoskeletal tissues, and a systematic comparison of the clearing ability of optical clearing agents in musculoskeletal tissues has yet to be fully demonstrated. In this study we tested the ability of eight different aqueous and non-aqueous clearing agents, with RIs ranging from 1.45 to 1.56, to optically clear murine knee joints and cortical bone. We demonstrated and quantified the ability of these optical clearing agents to clear musculoskeletal tissues and improve both macro- and micro-scale imaging of musculoskeletal tissue across several imaging modalities (stereomicroscopy, spectroscopy, and one-, and two-photon confocal microscopy) and investigational techniques (dynamic bone labeling and en bloc tissue staining). Based upon these findings we believe that optical clearing, in combination with advanced imaging techniques, has the potential to complement classical musculoskeletal analysis techniques; opening the door for improved in situ investigation and quantification of musculoskeletal tissues. |
format | Online Article Text |
id | pubmed-4773178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47731782016-03-07 Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing Berke, Ian M. Miola, Joseph P. David, Michael A. Smith, Melanie K. Price, Christopher PLoS One Research Article In situ, cells of the musculoskeletal system reside within complex and often interconnected 3-D environments. Key to better understanding how 3-D tissue and cellular environments regulate musculoskeletal physiology, homeostasis, and health is the use of robust methodologies for directly visualizing cell-cell and cell-matrix architecture in situ. However, the use of standard optical imaging techniques is often of limited utility in deep imaging of intact musculoskeletal tissues due to the highly scattering nature of biological tissues. Drawing inspiration from recent developments in the deep-tissue imaging field, we describe the application of immersion based optical clearing techniques, which utilize the principle of refractive index (RI) matching between the clearing/mounting media and tissue under observation, to improve the deep, in situ imaging of musculoskeletal tissues. To date, few optical clearing techniques have been applied specifically to musculoskeletal tissues, and a systematic comparison of the clearing ability of optical clearing agents in musculoskeletal tissues has yet to be fully demonstrated. In this study we tested the ability of eight different aqueous and non-aqueous clearing agents, with RIs ranging from 1.45 to 1.56, to optically clear murine knee joints and cortical bone. We demonstrated and quantified the ability of these optical clearing agents to clear musculoskeletal tissues and improve both macro- and micro-scale imaging of musculoskeletal tissue across several imaging modalities (stereomicroscopy, spectroscopy, and one-, and two-photon confocal microscopy) and investigational techniques (dynamic bone labeling and en bloc tissue staining). Based upon these findings we believe that optical clearing, in combination with advanced imaging techniques, has the potential to complement classical musculoskeletal analysis techniques; opening the door for improved in situ investigation and quantification of musculoskeletal tissues. Public Library of Science 2016-03-01 /pmc/articles/PMC4773178/ /pubmed/26930293 http://dx.doi.org/10.1371/journal.pone.0150268 Text en © 2016 Berke et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Berke, Ian M. Miola, Joseph P. David, Michael A. Smith, Melanie K. Price, Christopher Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title | Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title_full | Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title_fullStr | Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title_full_unstemmed | Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title_short | Seeing through Musculoskeletal Tissues: Improving In Situ Imaging of Bone and the Lacunar Canalicular System through Optical Clearing |
title_sort | seeing through musculoskeletal tissues: improving in situ imaging of bone and the lacunar canalicular system through optical clearing |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4773178/ https://www.ncbi.nlm.nih.gov/pubmed/26930293 http://dx.doi.org/10.1371/journal.pone.0150268 |
work_keys_str_mv | AT berkeianm seeingthroughmusculoskeletaltissuesimprovinginsituimagingofboneandthelacunarcanalicularsystemthroughopticalclearing AT miolajosephp seeingthroughmusculoskeletaltissuesimprovinginsituimagingofboneandthelacunarcanalicularsystemthroughopticalclearing AT davidmichaela seeingthroughmusculoskeletaltissuesimprovinginsituimagingofboneandthelacunarcanalicularsystemthroughopticalclearing AT smithmelaniek seeingthroughmusculoskeletaltissuesimprovinginsituimagingofboneandthelacunarcanalicularsystemthroughopticalclearing AT pricechristopher seeingthroughmusculoskeletaltissuesimprovinginsituimagingofboneandthelacunarcanalicularsystemthroughopticalclearing |