Cargando…
Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques
OBJECTIVE: To establish a supraorbital nerve sensory conduction recording method and assess its usefulness. METHODS: Thirty-one healthy subjects without a history of trauma or neurological disease were recruited. For the orthodromic procedure, the recording electrode was attached immediately superio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4775757/ https://www.ncbi.nlm.nih.gov/pubmed/26949668 http://dx.doi.org/10.5535/arm.2016.40.1.43 |
_version_ | 1782419051804360704 |
---|---|
author | Park, Hyeun Jun Kim, Sung-Hoon Lee, Se Kwang Lee, Hang Jae Kwon, Hee Kyu |
author_facet | Park, Hyeun Jun Kim, Sung-Hoon Lee, Se Kwang Lee, Hang Jae Kwon, Hee Kyu |
author_sort | Park, Hyeun Jun |
collection | PubMed |
description | OBJECTIVE: To establish a supraorbital nerve sensory conduction recording method and assess its usefulness. METHODS: Thirty-one healthy subjects without a history of trauma or neurological disease were recruited. For the orthodromic procedure, the recording electrode was attached immediately superior to the supraorbital notch. The stimulation electrode was placed on points along the hairline which evoked the largest sensory nerve action potentials (SNAPs). The antidromic sensory response was recorded after switching the recording and stimulating electrodes. The measured parameters were onset latency, peak latency, and baseline to peak amplitude of the SNAPs. The electrophysiological parameters of the bilateral supraorbital nerves were compared. We also recruited two patients who had sensory deficits on one side of their foreheads because of laceration injuries. RESULTS: The parameters of orthodromically recorded SNAPs were as follows: onset latency 1.21±0.22 ms (range, 0.9–1.6 ms), peak latency 1.54±0.23 ms (range, 1.2–2.2 ms), and baseline to peak amplitude 4.16±1.92 µV (range, 1.4–10 µV). Those of antidromically recorded SNAPs were onset latency 1.31±0.27 ms (range, 0.8–1.7 ms), peak latency 1.62±0.29 ms (range, 1.3–2.2 ms), and baseline to peak amplitude 4.00±1.89 µV (range, 1.5–9.0 µV). There was no statistical difference in onset latency, peak latency, or baseline to peak amplitude between the responses obtained using the orthodromic and antidromic methods, and the parameters also revealed no statistical difference between the supraorbital nerves on both sides. CONCLUSION: We have successfully recorded supraorbital SNAPs. This conduction technique could be quite useful in evaluating patients with supraorbital nerve lesions. |
format | Online Article Text |
id | pubmed-4775757 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-47757572016-03-06 Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques Park, Hyeun Jun Kim, Sung-Hoon Lee, Se Kwang Lee, Hang Jae Kwon, Hee Kyu Ann Rehabil Med Original Article OBJECTIVE: To establish a supraorbital nerve sensory conduction recording method and assess its usefulness. METHODS: Thirty-one healthy subjects without a history of trauma or neurological disease were recruited. For the orthodromic procedure, the recording electrode was attached immediately superior to the supraorbital notch. The stimulation electrode was placed on points along the hairline which evoked the largest sensory nerve action potentials (SNAPs). The antidromic sensory response was recorded after switching the recording and stimulating electrodes. The measured parameters were onset latency, peak latency, and baseline to peak amplitude of the SNAPs. The electrophysiological parameters of the bilateral supraorbital nerves were compared. We also recruited two patients who had sensory deficits on one side of their foreheads because of laceration injuries. RESULTS: The parameters of orthodromically recorded SNAPs were as follows: onset latency 1.21±0.22 ms (range, 0.9–1.6 ms), peak latency 1.54±0.23 ms (range, 1.2–2.2 ms), and baseline to peak amplitude 4.16±1.92 µV (range, 1.4–10 µV). Those of antidromically recorded SNAPs were onset latency 1.31±0.27 ms (range, 0.8–1.7 ms), peak latency 1.62±0.29 ms (range, 1.3–2.2 ms), and baseline to peak amplitude 4.00±1.89 µV (range, 1.5–9.0 µV). There was no statistical difference in onset latency, peak latency, or baseline to peak amplitude between the responses obtained using the orthodromic and antidromic methods, and the parameters also revealed no statistical difference between the supraorbital nerves on both sides. CONCLUSION: We have successfully recorded supraorbital SNAPs. This conduction technique could be quite useful in evaluating patients with supraorbital nerve lesions. Korean Academy of Rehabilitation Medicine 2016-02 2016-02-26 /pmc/articles/PMC4775757/ /pubmed/26949668 http://dx.doi.org/10.5535/arm.2016.40.1.43 Text en Copyright © 2016 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Hyeun Jun Kim, Sung-Hoon Lee, Se Kwang Lee, Hang Jae Kwon, Hee Kyu Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title | Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title_full | Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title_fullStr | Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title_full_unstemmed | Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title_short | Reappraisal of Supraorbital Sensory Nerve Conduction Recordings: Orthodromic and Antidromic Techniques |
title_sort | reappraisal of supraorbital sensory nerve conduction recordings: orthodromic and antidromic techniques |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4775757/ https://www.ncbi.nlm.nih.gov/pubmed/26949668 http://dx.doi.org/10.5535/arm.2016.40.1.43 |
work_keys_str_mv | AT parkhyeunjun reappraisalofsupraorbitalsensorynerveconductionrecordingsorthodromicandantidromictechniques AT kimsunghoon reappraisalofsupraorbitalsensorynerveconductionrecordingsorthodromicandantidromictechniques AT leesekwang reappraisalofsupraorbitalsensorynerveconductionrecordingsorthodromicandantidromictechniques AT leehangjae reappraisalofsupraorbitalsensorynerveconductionrecordingsorthodromicandantidromictechniques AT kwonheekyu reappraisalofsupraorbitalsensorynerveconductionrecordingsorthodromicandantidromictechniques |