Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance
BACKGROUND: Heart Failure (HF) is a common reason for hospitalization. Admissions might be prevented by early detection of and intervention for decompensation. Conventionally, changes in weight, a possible measure of fluid accumulation, have been used to detect deterioration. Transthoracic impedance...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Gunther Eysenbach
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4777885/ https://www.ncbi.nlm.nih.gov/pubmed/26892844 http://dx.doi.org/10.2196/medinform.4842 |
_version_ | 1782419364005281792 |
---|---|
author | Cuba Gyllensten, Illapha Bonomi, Alberto G Goode, Kevin M Reiter, Harald Habetha, Joerg Amft, Oliver Cleland, John GF |
author_facet | Cuba Gyllensten, Illapha Bonomi, Alberto G Goode, Kevin M Reiter, Harald Habetha, Joerg Amft, Oliver Cleland, John GF |
author_sort | Cuba Gyllensten, Illapha |
collection | PubMed |
description | BACKGROUND: Heart Failure (HF) is a common reason for hospitalization. Admissions might be prevented by early detection of and intervention for decompensation. Conventionally, changes in weight, a possible measure of fluid accumulation, have been used to detect deterioration. Transthoracic impedance may be a more sensitive and accurate measure of fluid accumulation. OBJECTIVE: In this study, we review previously proposed predictive algorithms using body weight and noninvasive transthoracic bio-impedance (NITTI) to predict HF decompensations. METHODS: We monitored 91 patients with chronic HF for an average of 10 months using a weight scale and a wearable bio-impedance vest. Three algorithms were tested using either simple rule-of-thumb differences (RoT), moving averages (MACD), or cumulative sums (CUSUM). RESULTS: Algorithms using NITTI in the 2 weeks preceding decompensation predicted events (P<.001); however, using weight alone did not. Cross-validation showed that NITTI improved sensitivity of all algorithms tested and that trend algorithms provided the best performance for either measurement (Weight-MACD: 33%, NITTI-CUSUM: 60%) in contrast to the simpler rules-of-thumb (Weight-RoT: 20%, NITTI-RoT: 33%) as proposed in HF guidelines. CONCLUSIONS: NITTI measurements decrease before decompensations, and combined with trend algorithms, improve the detection of HF decompensation over current guideline rules; however, many alerts are not associated with clinically overt decompensation. |
format | Online Article Text |
id | pubmed-4777885 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Gunther Eysenbach |
record_format | MEDLINE/PubMed |
spelling | pubmed-47778852016-03-18 Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance Cuba Gyllensten, Illapha Bonomi, Alberto G Goode, Kevin M Reiter, Harald Habetha, Joerg Amft, Oliver Cleland, John GF JMIR Med Inform Original Paper BACKGROUND: Heart Failure (HF) is a common reason for hospitalization. Admissions might be prevented by early detection of and intervention for decompensation. Conventionally, changes in weight, a possible measure of fluid accumulation, have been used to detect deterioration. Transthoracic impedance may be a more sensitive and accurate measure of fluid accumulation. OBJECTIVE: In this study, we review previously proposed predictive algorithms using body weight and noninvasive transthoracic bio-impedance (NITTI) to predict HF decompensations. METHODS: We monitored 91 patients with chronic HF for an average of 10 months using a weight scale and a wearable bio-impedance vest. Three algorithms were tested using either simple rule-of-thumb differences (RoT), moving averages (MACD), or cumulative sums (CUSUM). RESULTS: Algorithms using NITTI in the 2 weeks preceding decompensation predicted events (P<.001); however, using weight alone did not. Cross-validation showed that NITTI improved sensitivity of all algorithms tested and that trend algorithms provided the best performance for either measurement (Weight-MACD: 33%, NITTI-CUSUM: 60%) in contrast to the simpler rules-of-thumb (Weight-RoT: 20%, NITTI-RoT: 33%) as proposed in HF guidelines. CONCLUSIONS: NITTI measurements decrease before decompensations, and combined with trend algorithms, improve the detection of HF decompensation over current guideline rules; however, many alerts are not associated with clinically overt decompensation. Gunther Eysenbach 2016-02-18 /pmc/articles/PMC4777885/ /pubmed/26892844 http://dx.doi.org/10.2196/medinform.4842 Text en ©Illapha Cuba Gyllensten, Alberto G Bonomi, Kevin M Goode, Harald Reiter, Joerg Habetha, Oliver Amft, John GF Cleland. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 18.02.2016. https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/ (https://creativecommons.org/licenses/by/2.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on http://medinform.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Cuba Gyllensten, Illapha Bonomi, Alberto G Goode, Kevin M Reiter, Harald Habetha, Joerg Amft, Oliver Cleland, John GF Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title | Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title_full | Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title_fullStr | Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title_full_unstemmed | Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title_short | Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance |
title_sort | early indication of decompensated heart failure in patients on home-telemonitoring: a comparison of prediction algorithms based on daily weight and noninvasive transthoracic bio-impedance |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4777885/ https://www.ncbi.nlm.nih.gov/pubmed/26892844 http://dx.doi.org/10.2196/medinform.4842 |
work_keys_str_mv | AT cubagyllenstenillapha earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT bonomialbertog earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT goodekevinm earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT reiterharald earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT habethajoerg earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT amftoliver earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance AT clelandjohngf earlyindicationofdecompensatedheartfailureinpatientsonhometelemonitoringacomparisonofpredictionalgorithmsbasedondailyweightandnoninvasivetransthoracicbioimpedance |