Cargando…

A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia

BACKGROUND: Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost...

Descripción completa

Detalles Bibliográficos
Autores principales: Entenmann, Andreas, Schmiedel, Ronald, Michel, Miriam, Egender, Friedemann, Heßling, Vera, Dähnert, Ingo, Gebauer, Roman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778927/
https://www.ncbi.nlm.nih.gov/pubmed/26943363
http://dx.doi.org/10.1371/journal.pone.0150704
_version_ 1782419555706994688
author Entenmann, Andreas
Schmiedel, Ronald
Michel, Miriam
Egender, Friedemann
Heßling, Vera
Dähnert, Ingo
Gebauer, Roman
author_facet Entenmann, Andreas
Schmiedel, Ronald
Michel, Miriam
Egender, Friedemann
Heßling, Vera
Dähnert, Ingo
Gebauer, Roman
author_sort Entenmann, Andreas
collection PubMed
description BACKGROUND: Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. METHODS: A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. RESULTS: Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. CONCLUSIONS: A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique.
format Online
Article
Text
id pubmed-4778927
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47789272016-03-23 A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia Entenmann, Andreas Schmiedel, Ronald Michel, Miriam Egender, Friedemann Heßling, Vera Dähnert, Ingo Gebauer, Roman PLoS One Research Article BACKGROUND: Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. METHODS: A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. RESULTS: Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. CONCLUSIONS: A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique. Public Library of Science 2016-03-04 /pmc/articles/PMC4778927/ /pubmed/26943363 http://dx.doi.org/10.1371/journal.pone.0150704 Text en © 2016 Entenmann et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Entenmann, Andreas
Schmiedel, Ronald
Michel, Miriam
Egender, Friedemann
Heßling, Vera
Dähnert, Ingo
Gebauer, Roman
A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title_full A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title_fullStr A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title_full_unstemmed A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title_short A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia
title_sort low-cost simulation model for r-wave synchronized atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778927/
https://www.ncbi.nlm.nih.gov/pubmed/26943363
http://dx.doi.org/10.1371/journal.pone.0150704
work_keys_str_mv AT entenmannandreas alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT schmiedelronald alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT michelmiriam alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT egenderfriedemann alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT heßlingvera alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT dahnertingo alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT gebauerroman alowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT entenmannandreas lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT schmiedelronald lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT michelmiriam lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT egenderfriedemann lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT heßlingvera lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT dahnertingo lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia
AT gebauerroman lowcostsimulationmodelforrwavesynchronizedatrialpacinginpediatricpatientswithpostoperativejunctionalectopictachycardia