Cargando…

Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex

The purpose of this research is to develop an intuitive and robust realtime QRS detection algorithm based on the physiological characteristics of the electrocardiogram waveform. The proposed algorithm finds the QRS complex based on the dual criteria of the amplitude and duration of QRS complex. It c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jinkwon, Shin, Hangsik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778940/
https://www.ncbi.nlm.nih.gov/pubmed/26943949
http://dx.doi.org/10.1371/journal.pone.0150144
_version_ 1782419558533955584
author Kim, Jinkwon
Shin, Hangsik
author_facet Kim, Jinkwon
Shin, Hangsik
author_sort Kim, Jinkwon
collection PubMed
description The purpose of this research is to develop an intuitive and robust realtime QRS detection algorithm based on the physiological characteristics of the electrocardiogram waveform. The proposed algorithm finds the QRS complex based on the dual criteria of the amplitude and duration of QRS complex. It consists of simple operations, such as a finite impulse response filter, differentiation or thresholding without complex and computational operations like a wavelet transformation. The QRS detection performance is evaluated by using both an MIT-BIH arrhythmia database and an AHA ECG database (a total of 435,700 beats). The sensitivity (SE) and positive predictivity value (PPV) were 99.85% and 99.86%, respectively. According to the database, the SE and PPV were 99.90% and 99.91% in the MIT-BIH database and 99.84% and 99.84% in the AHA database, respectively. The result of the noisy environment test using record 119 from the MIT-BIH database indicated that the proposed method was scarcely affected by noise above 5 dB SNR (SE = 100%, PPV > 98%) without the need for an additional de-noising or back searching process.
format Online
Article
Text
id pubmed-4778940
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47789402016-03-23 Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex Kim, Jinkwon Shin, Hangsik PLoS One Research Article The purpose of this research is to develop an intuitive and robust realtime QRS detection algorithm based on the physiological characteristics of the electrocardiogram waveform. The proposed algorithm finds the QRS complex based on the dual criteria of the amplitude and duration of QRS complex. It consists of simple operations, such as a finite impulse response filter, differentiation or thresholding without complex and computational operations like a wavelet transformation. The QRS detection performance is evaluated by using both an MIT-BIH arrhythmia database and an AHA ECG database (a total of 435,700 beats). The sensitivity (SE) and positive predictivity value (PPV) were 99.85% and 99.86%, respectively. According to the database, the SE and PPV were 99.90% and 99.91% in the MIT-BIH database and 99.84% and 99.84% in the AHA database, respectively. The result of the noisy environment test using record 119 from the MIT-BIH database indicated that the proposed method was scarcely affected by noise above 5 dB SNR (SE = 100%, PPV > 98%) without the need for an additional de-noising or back searching process. Public Library of Science 2016-03-04 /pmc/articles/PMC4778940/ /pubmed/26943949 http://dx.doi.org/10.1371/journal.pone.0150144 Text en © 2016 Kim, Shin http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kim, Jinkwon
Shin, Hangsik
Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title_full Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title_fullStr Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title_full_unstemmed Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title_short Simple and Robust Realtime QRS Detection Algorithm Based on Spatiotemporal Characteristic of the QRS Complex
title_sort simple and robust realtime qrs detection algorithm based on spatiotemporal characteristic of the qrs complex
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4778940/
https://www.ncbi.nlm.nih.gov/pubmed/26943949
http://dx.doi.org/10.1371/journal.pone.0150144
work_keys_str_mv AT kimjinkwon simpleandrobustrealtimeqrsdetectionalgorithmbasedonspatiotemporalcharacteristicoftheqrscomplex
AT shinhangsik simpleandrobustrealtimeqrsdetectionalgorithmbasedonspatiotemporalcharacteristicoftheqrscomplex