Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study

BACKGROUND: The measurement of central corneal thickness (CCT) plays an important role in the diagnosis and treatment of glaucoma and many corneal diseases. OBJECTIVE OF THE STUDY: To compare the measurement of CCT by ultrasonic pachymeter with that measured by oculus pentacam in both normal subject...

Descripción completa

Detalles Bibliográficos
Autores principales: Rashid, Riyam Faihan, Farhood, Qasim K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4780203/
https://www.ncbi.nlm.nih.gov/pubmed/27041982
http://dx.doi.org/10.2147/OPTH.S96318
_version_ 1782419739376615424
author Rashid, Riyam Faihan
Farhood, Qasim K
author_facet Rashid, Riyam Faihan
Farhood, Qasim K
author_sort Rashid, Riyam Faihan
collection PubMed
description BACKGROUND: The measurement of central corneal thickness (CCT) plays an important role in the diagnosis and treatment of glaucoma and many corneal diseases. OBJECTIVE OF THE STUDY: To compare the measurement of CCT by ultrasonic pachymeter with that measured by oculus pentacam in both normal subjects and patients with well-controlled glaucoma. PATIENTS AND METHODS: In 173 eyes of both controls and patients with open-angle glaucoma (normal intraocular pressure) attending Ibn Al Haitham Teaching Eye Hospital, CCT was measured by oculus pentacam and then by ultrasound pachymeter at the same morning by the same technicians. RESULTS: The results showed no significant difference in CCT readings measured by the two devices in both glaucoma and control groups (glaucoma group: 547.29±49.32 µm with pentacam vs 547.66±45.24 µm with ultrasound pachymeter; control group: 551.02±36.28 µm with pentacam vs 541.25±34.96 µm with ultrasound pachymeter). P-values were >0.05 in both groups (statistically not significant). CONCLUSION AND RECOMMENDATION: Ultrasonic pachymeter and oculus pentacam can be used interchangeably in measuring CCT, and we recommend a nontouch method (in this study, pentacam Scheimpflug camera) for measuring CCT during assessment of patients with glaucoma or any ocular disease or surgery.
format Online
Article
Text
id pubmed-4780203
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-47802032016-04-01 Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study Rashid, Riyam Faihan Farhood, Qasim K Clin Ophthalmol Original Research BACKGROUND: The measurement of central corneal thickness (CCT) plays an important role in the diagnosis and treatment of glaucoma and many corneal diseases. OBJECTIVE OF THE STUDY: To compare the measurement of CCT by ultrasonic pachymeter with that measured by oculus pentacam in both normal subjects and patients with well-controlled glaucoma. PATIENTS AND METHODS: In 173 eyes of both controls and patients with open-angle glaucoma (normal intraocular pressure) attending Ibn Al Haitham Teaching Eye Hospital, CCT was measured by oculus pentacam and then by ultrasound pachymeter at the same morning by the same technicians. RESULTS: The results showed no significant difference in CCT readings measured by the two devices in both glaucoma and control groups (glaucoma group: 547.29±49.32 µm with pentacam vs 547.66±45.24 µm with ultrasound pachymeter; control group: 551.02±36.28 µm with pentacam vs 541.25±34.96 µm with ultrasound pachymeter). P-values were >0.05 in both groups (statistically not significant). CONCLUSION AND RECOMMENDATION: Ultrasonic pachymeter and oculus pentacam can be used interchangeably in measuring CCT, and we recommend a nontouch method (in this study, pentacam Scheimpflug camera) for measuring CCT during assessment of patients with glaucoma or any ocular disease or surgery. Dove Medical Press 2016-03-01 /pmc/articles/PMC4780203/ /pubmed/27041982 http://dx.doi.org/10.2147/OPTH.S96318 Text en © 2016 Rashid and Farhood. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Rashid, Riyam Faihan
Farhood, Qasim K
Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title_full Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title_fullStr Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title_full_unstemmed Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title_short Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
title_sort measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4780203/
https://www.ncbi.nlm.nih.gov/pubmed/27041982
http://dx.doi.org/10.2147/OPTH.S96318
work_keys_str_mv AT rashidriyamfaihan measurementofcentralcornealthicknessbyultrasonicpachymeterandoculuspentacaminpatientswithwellcontrolledglaucomahospitalbasedcomparativestudy
AT farhoodqasimk measurementofcentralcornealthicknessbyultrasonicpachymeterandoculuspentacaminpatientswithwellcontrolledglaucomahospitalbasedcomparativestudy