Cargando…

TotalTrack video intubating laryngeal mask in super-obese patients – series of cases

BACKGROUND: Super-obese patients are at increased risk of difficult mask ventilation and difficult intubation. Therefore, devices that allow for simultaneous ventilation/oxygenation during attempts to visualize the entrance to the larynx, increase patient safety. TotalTrack video intubating laryngea...

Descripción completa

Detalles Bibliográficos
Autor principal: Gaszynski, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4780402/
https://www.ncbi.nlm.nih.gov/pubmed/27042078
http://dx.doi.org/10.2147/TCRM.S95695
_version_ 1782419759567994880
author Gaszynski, Tomasz
author_facet Gaszynski, Tomasz
author_sort Gaszynski, Tomasz
collection PubMed
description BACKGROUND: Super-obese patients are at increased risk of difficult mask ventilation and difficult intubation. Therefore, devices that allow for simultaneous ventilation/oxygenation during attempts to visualize the entrance to the larynx, increase patient safety. TotalTrack video intubating laryngeal mask is a new device that allows for ventilation during intubation efforts. PATIENTS AND METHODS: Twenty-four super-obese patients (body mass index >50 kg/m(2)) were divided into two subgroups: intubation efforts using 1) TotalTrack and 2) Macintosh blade standard laryngoscope in induction of general anesthesia. Visualization and successful intubation was evaluated for both groups with ventilation and post-mask complications additionally evaluated for TotalTrack. RESULTS: In all cases in the TotalTrack group, the Cormack-Lehane score was 1, ventilation and intubation was successful in 11/12 patients. No hypoxia during intubation efforts was recorded. No serious complications of use of TotalTrack were observed. In the Macintosh blade laryngoscope group, all patients were intubated, but the Cormack-Lehane score was 2 in four cases, and 3 in three cases. CONCLUSION: TotalTrack video intubating laryngeal mask is a device that allows for better visualization of the larynx compared to the standard Macintosh blade laryngoscope, it provides effective ventilation/oxygenation and intubation in super-obese patients.
format Online
Article
Text
id pubmed-4780402
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-47804022016-04-01 TotalTrack video intubating laryngeal mask in super-obese patients – series of cases Gaszynski, Tomasz Ther Clin Risk Manag Original Research BACKGROUND: Super-obese patients are at increased risk of difficult mask ventilation and difficult intubation. Therefore, devices that allow for simultaneous ventilation/oxygenation during attempts to visualize the entrance to the larynx, increase patient safety. TotalTrack video intubating laryngeal mask is a new device that allows for ventilation during intubation efforts. PATIENTS AND METHODS: Twenty-four super-obese patients (body mass index >50 kg/m(2)) were divided into two subgroups: intubation efforts using 1) TotalTrack and 2) Macintosh blade standard laryngoscope in induction of general anesthesia. Visualization and successful intubation was evaluated for both groups with ventilation and post-mask complications additionally evaluated for TotalTrack. RESULTS: In all cases in the TotalTrack group, the Cormack-Lehane score was 1, ventilation and intubation was successful in 11/12 patients. No hypoxia during intubation efforts was recorded. No serious complications of use of TotalTrack were observed. In the Macintosh blade laryngoscope group, all patients were intubated, but the Cormack-Lehane score was 2 in four cases, and 3 in three cases. CONCLUSION: TotalTrack video intubating laryngeal mask is a device that allows for better visualization of the larynx compared to the standard Macintosh blade laryngoscope, it provides effective ventilation/oxygenation and intubation in super-obese patients. Dove Medical Press 2016-03-02 /pmc/articles/PMC4780402/ /pubmed/27042078 http://dx.doi.org/10.2147/TCRM.S95695 Text en © 2016 Gaszynski. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Gaszynski, Tomasz
TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title_full TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title_fullStr TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title_full_unstemmed TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title_short TotalTrack video intubating laryngeal mask in super-obese patients – series of cases
title_sort totaltrack video intubating laryngeal mask in super-obese patients – series of cases
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4780402/
https://www.ncbi.nlm.nih.gov/pubmed/27042078
http://dx.doi.org/10.2147/TCRM.S95695
work_keys_str_mv AT gaszynskitomasz totaltrackvideointubatinglaryngealmaskinsuperobesepatientsseriesofcases