Cargando…
A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood
Immunophenotyping of peripheral blood by flow cytometry determines changes in the frequency and activation status of peripheral leukocytes during disease and treatment. It has the potential to predict therapeutic efficacy and identify novel therapeutic targets. Whole blood staining utilizes unmanipu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4781742/ https://www.ncbi.nlm.nih.gov/pubmed/26890325 http://dx.doi.org/10.3791/53485 |
_version_ | 1782419829537374208 |
---|---|
author | Koguchi, Yoshinobu Gonzalez, Iliana L. Meeuwsen, Tanisha L. Miller, William L. Haley, Daniel P. Tanibata-Branham, Alice N. Bahjat, Keith S. |
author_facet | Koguchi, Yoshinobu Gonzalez, Iliana L. Meeuwsen, Tanisha L. Miller, William L. Haley, Daniel P. Tanibata-Branham, Alice N. Bahjat, Keith S. |
author_sort | Koguchi, Yoshinobu |
collection | PubMed |
description | Immunophenotyping of peripheral blood by flow cytometry determines changes in the frequency and activation status of peripheral leukocytes during disease and treatment. It has the potential to predict therapeutic efficacy and identify novel therapeutic targets. Whole blood staining utilizes unmanipulated blood, which minimizes artifacts that can occur during sample preparation. However, whole blood staining must also be done on freshly collected blood to ensure the integrity of the sample. Additionally, it is best to prepare antibody cocktails on the same day to avoid potential instability of tandem-dyes and prevent reagent interaction between brilliant violet dyes. Therefore, whole blood staining requires careful standardization to control for intra and inter-experimental variability. Here, we report deployment of an automated liquid handler equipped with a two-dimensional (2D) barcode reader into a standard process of making antibody cocktails for flow cytometry. Antibodies were transferred into 2D barcoded tubes arranged in a 96 well format and their contents compiled in a database. The liquid handler could then locate the source antibody vials by referencing antibody names within the database. Our method eliminated tedious coordination for positioning of source antibody tubes. It provided versatility allowing the user to easily change any number of details in the antibody dispensing process such as specific antibody to use, volume, and destination by modifying the database without rewriting the scripting in the software method for each assay. A proof of concept experiment achieved outstanding inter and intra- assay precision, demonstrated by replicate preparation of an 11-color, 17-antibody flow cytometry assay. These methodologies increased overall throughput for flow cytometry assays and facilitated daily preparation of the complex antibody cocktails required for the detailed phenotypic characterization of freshly collected anticoagulated peripheral blood. |
format | Online Article Text |
id | pubmed-4781742 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47817422016-03-09 A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood Koguchi, Yoshinobu Gonzalez, Iliana L. Meeuwsen, Tanisha L. Miller, William L. Haley, Daniel P. Tanibata-Branham, Alice N. Bahjat, Keith S. J Vis Exp Immunology Immunophenotyping of peripheral blood by flow cytometry determines changes in the frequency and activation status of peripheral leukocytes during disease and treatment. It has the potential to predict therapeutic efficacy and identify novel therapeutic targets. Whole blood staining utilizes unmanipulated blood, which minimizes artifacts that can occur during sample preparation. However, whole blood staining must also be done on freshly collected blood to ensure the integrity of the sample. Additionally, it is best to prepare antibody cocktails on the same day to avoid potential instability of tandem-dyes and prevent reagent interaction between brilliant violet dyes. Therefore, whole blood staining requires careful standardization to control for intra and inter-experimental variability. Here, we report deployment of an automated liquid handler equipped with a two-dimensional (2D) barcode reader into a standard process of making antibody cocktails for flow cytometry. Antibodies were transferred into 2D barcoded tubes arranged in a 96 well format and their contents compiled in a database. The liquid handler could then locate the source antibody vials by referencing antibody names within the database. Our method eliminated tedious coordination for positioning of source antibody tubes. It provided versatility allowing the user to easily change any number of details in the antibody dispensing process such as specific antibody to use, volume, and destination by modifying the database without rewriting the scripting in the software method for each assay. A proof of concept experiment achieved outstanding inter and intra- assay precision, demonstrated by replicate preparation of an 11-color, 17-antibody flow cytometry assay. These methodologies increased overall throughput for flow cytometry assays and facilitated daily preparation of the complex antibody cocktails required for the detailed phenotypic characterization of freshly collected anticoagulated peripheral blood. MyJove Corporation 2016-02-08 /pmc/articles/PMC4781742/ /pubmed/26890325 http://dx.doi.org/10.3791/53485 Text en Copyright © 2016, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Immunology Koguchi, Yoshinobu Gonzalez, Iliana L. Meeuwsen, Tanisha L. Miller, William L. Haley, Daniel P. Tanibata-Branham, Alice N. Bahjat, Keith S. A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title | A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title_full | A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title_fullStr | A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title_full_unstemmed | A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title_short | A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood |
title_sort | semi-automated approach to preparing antibody cocktails for immunophenotypic analysis of human peripheral blood |
topic | Immunology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4781742/ https://www.ncbi.nlm.nih.gov/pubmed/26890325 http://dx.doi.org/10.3791/53485 |
work_keys_str_mv | AT koguchiyoshinobu asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT gonzalezilianal asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT meeuwsentanishal asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT millerwilliaml asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT haleydanielp asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT tanibatabranhamalicen asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT bahjatkeiths asemiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT koguchiyoshinobu semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT gonzalezilianal semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT meeuwsentanishal semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT millerwilliaml semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT haleydanielp semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT tanibatabranhamalicen semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood AT bahjatkeiths semiautomatedapproachtopreparingantibodycocktailsforimmunophenotypicanalysisofhumanperipheralblood |