Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology
This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed b...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4782681/ https://www.ncbi.nlm.nih.gov/pubmed/27006940 http://dx.doi.org/10.1155/2015/701520 |
_version_ | 1782420003245522944 |
---|---|
author | Singh, Om Prakash Mekonnen, Dawit Malarvili, M. B. |
author_facet | Singh, Om Prakash Mekonnen, Dawit Malarvili, M. B. |
author_sort | Singh, Om Prakash |
collection | PubMed |
description | This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet. |
format | Online Article Text |
id | pubmed-4782681 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47826812016-03-22 Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology Singh, Om Prakash Mekonnen, Dawit Malarvili, M. B. J Med Eng Research Article This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet. Hindawi Publishing Corporation 2015 2015-12-10 /pmc/articles/PMC4782681/ /pubmed/27006940 http://dx.doi.org/10.1155/2015/701520 Text en Copyright © 2015 Om Prakash Singh et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Singh, Om Prakash Mekonnen, Dawit Malarvili, M. B. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title | Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title_full | Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title_fullStr | Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title_full_unstemmed | Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title_short | Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology |
title_sort | labview based ecg patient monitoring system for cardiovascular patient using smtp technology |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4782681/ https://www.ncbi.nlm.nih.gov/pubmed/27006940 http://dx.doi.org/10.1155/2015/701520 |
work_keys_str_mv | AT singhomprakash labviewbasedecgpatientmonitoringsystemforcardiovascularpatientusingsmtptechnology AT mekonnendawit labviewbasedecgpatientmonitoringsystemforcardiovascularpatientusingsmtptechnology AT malarvilimb labviewbasedecgpatientmonitoringsystemforcardiovascularpatientusingsmtptechnology |