Cargando…

OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS

Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and t...

Descripción completa

Detalles Bibliográficos
Autores principales: Cohen, Marcio, Amaral, Marcus Vinicius, Monteiro, Martim, Brandão, Bruno Lobo, Motta Filho, Geraldo Rocha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783608/
https://www.ncbi.nlm.nih.gov/pubmed/26998460
http://dx.doi.org/10.1016/S2255-4971(15)30056-2
_version_ 1782420141508657152
author Cohen, Marcio
Amaral, Marcus Vinicius
Monteiro, Martim
Brandão, Bruno Lobo
Motta Filho, Geraldo Rocha
author_facet Cohen, Marcio
Amaral, Marcus Vinicius
Monteiro, Martim
Brandão, Bruno Lobo
Motta Filho, Geraldo Rocha
author_sort Cohen, Marcio
collection PubMed
description Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria. Results: The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points. Conclusion: Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome.
format Online
Article
Text
id pubmed-4783608
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-47836082016-03-18 OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS Cohen, Marcio Amaral, Marcus Vinicius Monteiro, Martim Brandão, Bruno Lobo Motta Filho, Geraldo Rocha Rev Bras Ortop Original Article Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria. Results: The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points. Conclusion: Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome. Elsevier 2015-11-16 /pmc/articles/PMC4783608/ /pubmed/26998460 http://dx.doi.org/10.1016/S2255-4971(15)30056-2 Text en © 2009 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Cohen, Marcio
Amaral, Marcus Vinicius
Monteiro, Martim
Brandão, Bruno Lobo
Motta Filho, Geraldo Rocha
OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title_full OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title_fullStr OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title_full_unstemmed OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title_short OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
title_sort osteosynthesis of proximal humeral end fractures with fixed-angle plate and locking screws: technique and results
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783608/
https://www.ncbi.nlm.nih.gov/pubmed/26998460
http://dx.doi.org/10.1016/S2255-4971(15)30056-2
work_keys_str_mv AT cohenmarcio osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults
AT amaralmarcusvinicius osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults
AT monteiromartim osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults
AT brandaobrunolobo osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults
AT mottafilhogeraldorocha osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults