OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783608/ https://www.ncbi.nlm.nih.gov/pubmed/26998460 http://dx.doi.org/10.1016/S2255-4971(15)30056-2 |
_version_ | 1782420141508657152 |
---|---|
author | Cohen, Marcio Amaral, Marcus Vinicius Monteiro, Martim Brandão, Bruno Lobo Motta Filho, Geraldo Rocha |
author_facet | Cohen, Marcio Amaral, Marcus Vinicius Monteiro, Martim Brandão, Bruno Lobo Motta Filho, Geraldo Rocha |
author_sort | Cohen, Marcio |
collection | PubMed |
description | Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria. Results: The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points. Conclusion: Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome. |
format | Online Article Text |
id | pubmed-4783608 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47836082016-03-18 OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS Cohen, Marcio Amaral, Marcus Vinicius Monteiro, Martim Brandão, Bruno Lobo Motta Filho, Geraldo Rocha Rev Bras Ortop Original Article Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria. Results: The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points. Conclusion: Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome. Elsevier 2015-11-16 /pmc/articles/PMC4783608/ /pubmed/26998460 http://dx.doi.org/10.1016/S2255-4971(15)30056-2 Text en © 2009 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Cohen, Marcio Amaral, Marcus Vinicius Monteiro, Martim Brandão, Bruno Lobo Motta Filho, Geraldo Rocha OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title | OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title_full | OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title_fullStr | OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title_full_unstemmed | OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title_short | OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS |
title_sort | osteosynthesis of proximal humeral end fractures with fixed-angle plate and locking screws: technique and results |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783608/ https://www.ncbi.nlm.nih.gov/pubmed/26998460 http://dx.doi.org/10.1016/S2255-4971(15)30056-2 |
work_keys_str_mv | AT cohenmarcio osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults AT amaralmarcusvinicius osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults AT monteiromartim osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults AT brandaobrunolobo osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults AT mottafilhogeraldorocha osteosynthesisofproximalhumeralendfractureswithfixedangleplateandlockingscrewstechniqueandresults |