Cargando…
OSTEOSYNTHESIS OF PROXIMAL HUMERAL END FRACTURES WITH FIXED-ANGLE PLATE AND LOCKING SCREWS: TECHNIQUE AND RESULTS
Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. Method: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and t...
Autores principales: | Cohen, Marcio, Amaral, Marcus Vinicius, Monteiro, Martim, Brandão, Bruno Lobo, Motta Filho, Geraldo Rocha |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783608/ https://www.ncbi.nlm.nih.gov/pubmed/26998460 http://dx.doi.org/10.1016/S2255-4971(15)30056-2 |
Ejemplares similares
-
Dynamic locking screws in proximal humeral plate osteosynthesis demonstrate superior fixation properties: a biomechanical study
por: Sandmann, Gunther, et al.
Publicado: (2020) -
Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
por: Kim, Beom-Soo, et al.
Publicado: (2022) -
Arthroscopic assisted removal of screws from proximal humeral locking plates
por: Dattani, Rupen, et al.
Publicado: (2013) -
Fluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of “Plate” and “Screw” Views
por: Kanchanatawan, Wichan, et al.
Publicado: (2017) -
Is Loss of Fixation Following Locked Plating of Proximal Humeral Fractures Related to the Number of Screws and Their Positions in the Humeral Head?
por: Maddah, Mohammad, et al.
Publicado: (2014)