Cargando…
RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
Objectives: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. Methods: Sixty male subjects were invited to participa...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783672/ https://www.ncbi.nlm.nih.gov/pubmed/27004175 http://dx.doi.org/10.1016/S2255-4971(15)30071-9 |
_version_ | 1782420149941305344 |
---|---|
author | de Vasconcelos, Rodrigo Antunes Bevilaqua-Grossi, Débora Shimano, Antonio Carlos Paccola, Cleber Jansen Salvini, Tânia Fátima Prado, Christiane Lanatovits Junior, Wilson A. Mello |
author_facet | de Vasconcelos, Rodrigo Antunes Bevilaqua-Grossi, Débora Shimano, Antonio Carlos Paccola, Cleber Jansen Salvini, Tânia Fátima Prado, Christiane Lanatovits Junior, Wilson A. Mello |
author_sort | de Vasconcelos, Rodrigo Antunes |
collection | PubMed |
description | Objectives: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. Methods: Sixty male subjects were invited to participate of the study, being divided into three groups with 20 subjects each: control group (GC), group of individuals with ACL reconstruction with patellar tendon graft (GTP, and group of individuals with ACL reconstruction with hamstrings graft (GTF). All individuals performed isometric tests in the MID, muscular strength deficits collected were subsequently compared to the tests performed on the Biodex System 3 operating in the isometric and isokinetic mode at speeds of 60°/s and 180o/s. Intraclass ICC correlation calculations were done in order to assess MID reliability, specificity, sensitivity and Kappa's consistency coefficient calculations, respectively, for assessing the MID's validity in detecting muscular deficits and intra- and intergroup comparisons when performing the four strength tests using the ANOVA method. Results: The modified isometric dynamometer (MID) showed excellent reliability and good validity in the assessment of the performance of the knee extensor and flexor muscles groups. In the comparison between groups, the GTP showed significantly greater deficits as compared to the GTF and GC groups. Conclusion: Isometric dynamometers connected to mechanotherapy equipments could be an alternative option to collect data concerning performance deficits of the extensor and flexor muscles groups of the knee in subjects with ACL reconstruction. |
format | Online Article Text |
id | pubmed-4783672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47836722016-03-21 RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION de Vasconcelos, Rodrigo Antunes Bevilaqua-Grossi, Débora Shimano, Antonio Carlos Paccola, Cleber Jansen Salvini, Tânia Fátima Prado, Christiane Lanatovits Junior, Wilson A. Mello Rev Bras Ortop Original Article Objectives: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. Methods: Sixty male subjects were invited to participate of the study, being divided into three groups with 20 subjects each: control group (GC), group of individuals with ACL reconstruction with patellar tendon graft (GTP, and group of individuals with ACL reconstruction with hamstrings graft (GTF). All individuals performed isometric tests in the MID, muscular strength deficits collected were subsequently compared to the tests performed on the Biodex System 3 operating in the isometric and isokinetic mode at speeds of 60°/s and 180o/s. Intraclass ICC correlation calculations were done in order to assess MID reliability, specificity, sensitivity and Kappa's consistency coefficient calculations, respectively, for assessing the MID's validity in detecting muscular deficits and intra- and intergroup comparisons when performing the four strength tests using the ANOVA method. Results: The modified isometric dynamometer (MID) showed excellent reliability and good validity in the assessment of the performance of the knee extensor and flexor muscles groups. In the comparison between groups, the GTP showed significantly greater deficits as compared to the GTF and GC groups. Conclusion: Isometric dynamometers connected to mechanotherapy equipments could be an alternative option to collect data concerning performance deficits of the extensor and flexor muscles groups of the knee in subjects with ACL reconstruction. Elsevier 2015-11-16 /pmc/articles/PMC4783672/ /pubmed/27004175 http://dx.doi.org/10.1016/S2255-4971(15)30071-9 Text en © 2009 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article de Vasconcelos, Rodrigo Antunes Bevilaqua-Grossi, Débora Shimano, Antonio Carlos Paccola, Cleber Jansen Salvini, Tânia Fátima Prado, Christiane Lanatovits Junior, Wilson A. Mello RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title | RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title_full | RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title_fullStr | RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title_full_unstemmed | RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title_short | RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION |
title_sort | reliability and validity of a modified isometric dynamometer in the assessment of muscular performance in individuals with anterior cruciate ligament reconstruction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4783672/ https://www.ncbi.nlm.nih.gov/pubmed/27004175 http://dx.doi.org/10.1016/S2255-4971(15)30071-9 |
work_keys_str_mv | AT devasconcelosrodrigoantunes reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT bevilaquagrossidebora reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT shimanoantoniocarlos reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT paccolacleberjansen reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT salvinitaniafatima reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT pradochristianelanatovits reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction AT juniorwilsonamello reliabilityandvalidityofamodifiedisometricdynamometerintheassessmentofmuscularperformanceinindividualswithanteriorcruciateligamentreconstruction |