Localizing the optic disc (OD) in retinal fundus images is of critical importance and many techniques have been developed for OD detection. In this paper, we present the results obtained from two fast methods, correlation and least square, to approximate the location of optic cup. These methods are...

Descripción completa

Detalles Bibliográficos
Autores principales: Jamshidi, M., Rabbani, H., Amini, Z., Kafieh, R., Ommani, A., Lakshminarayanan, V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4786964/
https://www.ncbi.nlm.nih.gov/pubmed/27014613
Descripción
Sumario:Localizing the optic disc (OD) in retinal fundus images is of critical importance and many techniques have been developed for OD detection. In this paper, we present the results obtained from two fast methods, correlation and least square, to approximate the location of optic cup. These methods are simple and are not complex, while most of the OD detection algorithms are. The methods were tested on two groups of data (a total of 100 color fundus images) and were 98% successful in the detection of the optic cup. An algorithm using the vessel mask of fundus images is proposed to be run after correlation to ensure that the localization of OD in all images is successful. It was tested on 40 of the test images and had a 100% rate of success.