IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification

The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-IT...

Descripción completa

Detalles Bibliográficos
Autores principales: Venchiarutti, C., Varga, Z., Richter, S., Nicholl, A., Krajko, J., Jakopič, R., Mayer, K., Aregbe, Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4788687/
https://www.ncbi.nlm.nih.gov/pubmed/27069295
http://dx.doi.org/10.1007/s10967-015-4368-y
_version_ 1782420752886136832
author Venchiarutti, C.
Varga, Z.
Richter, S.
Nicholl, A.
Krajko, J.
Jakopič, R.
Mayer, K.
Aregbe, Y.
author_facet Venchiarutti, C.
Varga, Z.
Richter, S.
Nicholl, A.
Krajko, J.
Jakopič, R.
Mayer, K.
Aregbe, Y.
author_sort Venchiarutti, C.
collection PubMed
description The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-ITU). They are novel uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer, i.e. the date of the last chemical separation of these two radionuclides. The certified reference value and its uncertainty, homogeneity and stability of the material were established in accordance with the ISO Guide 34:2009 and the ‘Guide to the Expression of Uncertainty in Measurement’.
format Online
Article
Text
id pubmed-4788687
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-47886872016-04-09 IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification Venchiarutti, C. Varga, Z. Richter, S. Nicholl, A. Krajko, J. Jakopič, R. Mayer, K. Aregbe, Y. J Radioanal Nucl Chem Article The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-ITU). They are novel uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer, i.e. the date of the last chemical separation of these two radionuclides. The certified reference value and its uncertainty, homogeneity and stability of the material were established in accordance with the ISO Guide 34:2009 and the ‘Guide to the Expression of Uncertainty in Measurement’. Springer Netherlands 2015-09-04 2016 /pmc/articles/PMC4788687/ /pubmed/27069295 http://dx.doi.org/10.1007/s10967-015-4368-y Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Venchiarutti, C.
Varga, Z.
Richter, S.
Nicholl, A.
Krajko, J.
Jakopič, R.
Mayer, K.
Aregbe, Y.
IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title_full IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title_fullStr IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title_full_unstemmed IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title_short IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
title_sort irmm-1000a and irmm-1000b: uranium reference materials certified for the production date based on the (230)th/(234)u radiochronometer. part ii: certification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4788687/
https://www.ncbi.nlm.nih.gov/pubmed/27069295
http://dx.doi.org/10.1007/s10967-015-4368-y
work_keys_str_mv AT venchiaruttic irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT vargaz irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT richters irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT nicholla irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT krajkoj irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT jakopicr irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT mayerk irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification
AT aregbey irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification