Cargando…
IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification
The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-IT...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4788687/ https://www.ncbi.nlm.nih.gov/pubmed/27069295 http://dx.doi.org/10.1007/s10967-015-4368-y |
_version_ | 1782420752886136832 |
---|---|
author | Venchiarutti, C. Varga, Z. Richter, S. Nicholl, A. Krajko, J. Jakopič, R. Mayer, K. Aregbe, Y. |
author_facet | Venchiarutti, C. Varga, Z. Richter, S. Nicholl, A. Krajko, J. Jakopič, R. Mayer, K. Aregbe, Y. |
author_sort | Venchiarutti, C. |
collection | PubMed |
description | The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-ITU). They are novel uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer, i.e. the date of the last chemical separation of these two radionuclides. The certified reference value and its uncertainty, homogeneity and stability of the material were established in accordance with the ISO Guide 34:2009 and the ‘Guide to the Expression of Uncertainty in Measurement’. |
format | Online Article Text |
id | pubmed-4788687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-47886872016-04-09 IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification Venchiarutti, C. Varga, Z. Richter, S. Nicholl, A. Krajko, J. Jakopič, R. Mayer, K. Aregbe, Y. J Radioanal Nucl Chem Article The IRMM-1000a and IRMM-1000b uranium reference materials, of 20 and 50 mg uranium, respectively, were produced by the European Commission Joint Research Centre’s Institute for Reference Materials and Measurements (EC-JRC-IRMM) in collaboration with the Institute for Transuranium Elements (EC-JRC-ITU). They are novel uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer, i.e. the date of the last chemical separation of these two radionuclides. The certified reference value and its uncertainty, homogeneity and stability of the material were established in accordance with the ISO Guide 34:2009 and the ‘Guide to the Expression of Uncertainty in Measurement’. Springer Netherlands 2015-09-04 2016 /pmc/articles/PMC4788687/ /pubmed/27069295 http://dx.doi.org/10.1007/s10967-015-4368-y Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Venchiarutti, C. Varga, Z. Richter, S. Nicholl, A. Krajko, J. Jakopič, R. Mayer, K. Aregbe, Y. IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title | IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title_full | IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title_fullStr | IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title_full_unstemmed | IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title_short | IRMM-1000a and IRMM-1000b: uranium reference materials certified for the production date based on the (230)Th/(234)U radiochronometer. Part II: certification |
title_sort | irmm-1000a and irmm-1000b: uranium reference materials certified for the production date based on the (230)th/(234)u radiochronometer. part ii: certification |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4788687/ https://www.ncbi.nlm.nih.gov/pubmed/27069295 http://dx.doi.org/10.1007/s10967-015-4368-y |
work_keys_str_mv | AT venchiaruttic irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT vargaz irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT richters irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT nicholla irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT krajkoj irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT jakopicr irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT mayerk irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification AT aregbey irmm1000aandirmm1000buraniumreferencematerialscertifiedfortheproductiondatebasedonthe230th234uradiochronometerpartiicertification |