Cargando…
Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis
BACKGROUND: To explore the efficacy of tranexamic acid (TXA) on reducing hidden blood loss (HBL) in total knee arthroplasty (TKA) by conducting a comparative study and meta-analysis. MATERIAL/METHODS: A total of 108 patients underwent TKA was equally distributed to experimental and control groups. T...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4790217/ https://www.ncbi.nlm.nih.gov/pubmed/26961597 http://dx.doi.org/10.12659/MSM.895571 |
_version_ | 1782420961087193088 |
---|---|
author | Huang, Guang-Ping Jia, Xu-Feng Xiang, Zhou Ji, Yong Wu, Guo-Yong Tang, Yi Li, Jian Zhang, Jun |
author_facet | Huang, Guang-Ping Jia, Xu-Feng Xiang, Zhou Ji, Yong Wu, Guo-Yong Tang, Yi Li, Jian Zhang, Jun |
author_sort | Huang, Guang-Ping |
collection | PubMed |
description | BACKGROUND: To explore the efficacy of tranexamic acid (TXA) on reducing hidden blood loss (HBL) in total knee arthroplasty (TKA) by conducting a comparative study and meta-analysis. MATERIAL/METHODS: A total of 108 patients underwent TKA was equally distributed to experimental and control groups. The only difference between two groups was the administrations of 15 mg of TXA mixed in 100 mL normal saline for experimental group and 100 mL of normal saline for control group. The volumes of blood loss, red blood loss (RBL) were recorded, calculated and analyzed. Stata 12.0 software was applied for data analysis. RESULTS: The intraoperative and postoperative blood loss volume in experimental group were remarkably reduced compared with those in control group (intraoperative: 105.1±12.1 mL vs. 185.5±20.3 mL, P<0.001; postoperative: 220.7±16.8 mL vs. 290.5±22.4 mL, P<0.001). Accordingly, the control group had significantly higher transfusion rate than experimental group (3.7% vs.25.9%, P=0.001). Our results also found that both the measured and hidden RBL were obviously reduced in experimental group compared with control group (measured RBL: 96.9±11.8 mL vs. 135.2±13.5 mL, P<0.001; hidden RBL: 170.8±37.2 mL vs. 364.2±41.5 mL, P<0.001). Furthermore, meta-analysis confirmed that TXA can notably decrease HBL (SMD=2.68, 95%CI=1.55~3.80, P<0.001). CONCLUSIONS: TXA can significantly reduce the intraoperative and postoperative blood loss and HBL, therefore decreasing the transfusion need in TKA. |
format | Online Article Text |
id | pubmed-4790217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-47902172016-03-29 Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis Huang, Guang-Ping Jia, Xu-Feng Xiang, Zhou Ji, Yong Wu, Guo-Yong Tang, Yi Li, Jian Zhang, Jun Med Sci Monit Meta-Analysis BACKGROUND: To explore the efficacy of tranexamic acid (TXA) on reducing hidden blood loss (HBL) in total knee arthroplasty (TKA) by conducting a comparative study and meta-analysis. MATERIAL/METHODS: A total of 108 patients underwent TKA was equally distributed to experimental and control groups. The only difference between two groups was the administrations of 15 mg of TXA mixed in 100 mL normal saline for experimental group and 100 mL of normal saline for control group. The volumes of blood loss, red blood loss (RBL) were recorded, calculated and analyzed. Stata 12.0 software was applied for data analysis. RESULTS: The intraoperative and postoperative blood loss volume in experimental group were remarkably reduced compared with those in control group (intraoperative: 105.1±12.1 mL vs. 185.5±20.3 mL, P<0.001; postoperative: 220.7±16.8 mL vs. 290.5±22.4 mL, P<0.001). Accordingly, the control group had significantly higher transfusion rate than experimental group (3.7% vs.25.9%, P=0.001). Our results also found that both the measured and hidden RBL were obviously reduced in experimental group compared with control group (measured RBL: 96.9±11.8 mL vs. 135.2±13.5 mL, P<0.001; hidden RBL: 170.8±37.2 mL vs. 364.2±41.5 mL, P<0.001). Furthermore, meta-analysis confirmed that TXA can notably decrease HBL (SMD=2.68, 95%CI=1.55~3.80, P<0.001). CONCLUSIONS: TXA can significantly reduce the intraoperative and postoperative blood loss and HBL, therefore decreasing the transfusion need in TKA. International Scientific Literature, Inc. 2016-03-10 /pmc/articles/PMC4790217/ /pubmed/26961597 http://dx.doi.org/10.12659/MSM.895571 Text en © Med Sci Monit, 2016 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License |
spellingShingle | Meta-Analysis Huang, Guang-Ping Jia, Xu-Feng Xiang, Zhou Ji, Yong Wu, Guo-Yong Tang, Yi Li, Jian Zhang, Jun Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title | Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title_full | Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title_fullStr | Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title_full_unstemmed | Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title_short | Tranexamic Acid Reduces Hidden Blood Loss in Patients Undergoing Total Knee Arthroplasty: A Comparative Study and Meta-Analysis |
title_sort | tranexamic acid reduces hidden blood loss in patients undergoing total knee arthroplasty: a comparative study and meta-analysis |
topic | Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4790217/ https://www.ncbi.nlm.nih.gov/pubmed/26961597 http://dx.doi.org/10.12659/MSM.895571 |
work_keys_str_mv | AT huangguangping tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT jiaxufeng tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT xiangzhou tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT jiyong tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT wuguoyong tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT tangyi tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT lijian tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis AT zhangjun tranexamicacidreduceshiddenbloodlossinpatientsundergoingtotalkneearthroplastyacomparativestudyandmetaanalysis |