Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial

Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very o...

Descripción completa

Detalles Bibliográficos
Autores principales: Applegate, Richard L., Lenart, John, Malkin, Mathew, Meineke, Minhthy N., Qoshlli, Silvana, Neumann, Monica, Jacobson, J. Paul, Kruger, Alison, Ching, Jeffrey, Hassanian, Mohammad, Um, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2016
Materias:
8
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791313/
https://www.ncbi.nlm.nih.gov/pubmed/26836134
http://dx.doi.org/10.1213/ANE.0000000000001160
_version_ 1782421067724226560
author Applegate, Richard L.
Lenart, John
Malkin, Mathew
Meineke, Minhthy N.
Qoshlli, Silvana
Neumann, Monica
Jacobson, J. Paul
Kruger, Alison
Ching, Jeffrey
Hassanian, Mohammad
Um, Michael
author_facet Applegate, Richard L.
Lenart, John
Malkin, Mathew
Meineke, Minhthy N.
Qoshlli, Silvana
Neumann, Monica
Jacobson, J. Paul
Kruger, Alison
Ching, Jeffrey
Hassanian, Mohammad
Um, Michael
author_sort Applegate, Richard L.
collection PubMed
description Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very old, or sicker patients. Monitoring with pulse oximetry may underreport hypoventilation during sedation, particularly if supplemental oxygen is provided. Capnometry may result in false alarms during sedation when patients mouth breathe or displace sampling devices. Advanced monitor use during sedation may allow event detection before complications develop. This 2-part pilot study used advanced monitors during planned moderate sedation to (1) determine incidences of desaturation, low respiratory rate, and deeper than intended sedation alarm events; and (2) determine whether advanced monitor use is associated with fewer alarm events. METHODS: Adult patients undergoing scheduled gastroenterology or interventional radiology procedures with planned moderate sedation given by dedicated sedation nurses under the direction of procedural physicians (procedural sedation team) were monitored per standard protocols (electrocardiography blood pressure, pulse oximetry, and capnometry) and advanced monitors (acoustic respiratory monitoring and processed electroencephalograpy). Data were collected to computers for analysis. Advanced monitor parameters were not visible to teams in part 1 (standard) but were visible to teams in part 2 (advanced). Alarm events were defined as desaturation—Spo(2) ≤92%; respiratory depression, acoustic respiratory rate ≤8 breaths per minute, and deeper than intended sedation, indicated by processed electroencephalograpy. The number of alarm events was compared. RESULTS: Of 100 patients enrolled, 10 were excluded for data collection computer malfunction or consent withdrawal. Data were analyzed from 90 patients (44 standard and 46 advanced). Advanced had fewer total alarms than standard (Wilcoxon-Mann-Whitney = 2.073, P = 0.038; Wilcoxon-Mann-Whitney odds, 1.67; 95% confidence interval [CI], 1.04–2.88). Similar numbers of standard and advanced had ≥1 alarm event (Wald difference, −10.2%; 95% CI, −26.4% to 7.0%; P = 0.237). Fewer advanced patients had ≥1 respiratory depression event (Wald difference, −22.1%; 95% CI, −40.9% to −2.4%; P = 0.036) or ≥1 desaturation event (Wald difference, −24.2%; 95% CI, −42.8% to −3.6%; P = 0.021); but there was no significant difference in deeper than intended sedation events (Wald difference, −1.38%; 95% CI, −20.21% to 17.49%; P = 0.887). CONCLUSIONS: Use of advanced monitoring parameters during planned moderate sedation was associated with fewer alarm events, patients experiencing desaturation, and patients experiencing respiratory depression alarm events. This pilot study suggests that further study into the safety and outcome impacts of advanced monitoring during procedure-related sedation is warranted.
format Online
Article
Text
id pubmed-4791313
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-47913132016-04-05 Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial Applegate, Richard L. Lenart, John Malkin, Mathew Meineke, Minhthy N. Qoshlli, Silvana Neumann, Monica Jacobson, J. Paul Kruger, Alison Ching, Jeffrey Hassanian, Mohammad Um, Michael Anesth Analg 8 Diagnostic and interventional procedures are often facilitated by moderate procedure-related sedation. Many studies support the overall safety of this sedation; however, adverse cardiovascular and respiratory events are reported in up to 70% of these procedures, more frequently in very young, very old, or sicker patients. Monitoring with pulse oximetry may underreport hypoventilation during sedation, particularly if supplemental oxygen is provided. Capnometry may result in false alarms during sedation when patients mouth breathe or displace sampling devices. Advanced monitor use during sedation may allow event detection before complications develop. This 2-part pilot study used advanced monitors during planned moderate sedation to (1) determine incidences of desaturation, low respiratory rate, and deeper than intended sedation alarm events; and (2) determine whether advanced monitor use is associated with fewer alarm events. METHODS: Adult patients undergoing scheduled gastroenterology or interventional radiology procedures with planned moderate sedation given by dedicated sedation nurses under the direction of procedural physicians (procedural sedation team) were monitored per standard protocols (electrocardiography blood pressure, pulse oximetry, and capnometry) and advanced monitors (acoustic respiratory monitoring and processed electroencephalograpy). Data were collected to computers for analysis. Advanced monitor parameters were not visible to teams in part 1 (standard) but were visible to teams in part 2 (advanced). Alarm events were defined as desaturation—Spo(2) ≤92%; respiratory depression, acoustic respiratory rate ≤8 breaths per minute, and deeper than intended sedation, indicated by processed electroencephalograpy. The number of alarm events was compared. RESULTS: Of 100 patients enrolled, 10 were excluded for data collection computer malfunction or consent withdrawal. Data were analyzed from 90 patients (44 standard and 46 advanced). Advanced had fewer total alarms than standard (Wilcoxon-Mann-Whitney = 2.073, P = 0.038; Wilcoxon-Mann-Whitney odds, 1.67; 95% confidence interval [CI], 1.04–2.88). Similar numbers of standard and advanced had ≥1 alarm event (Wald difference, −10.2%; 95% CI, −26.4% to 7.0%; P = 0.237). Fewer advanced patients had ≥1 respiratory depression event (Wald difference, −22.1%; 95% CI, −40.9% to −2.4%; P = 0.036) or ≥1 desaturation event (Wald difference, −24.2%; 95% CI, −42.8% to −3.6%; P = 0.021); but there was no significant difference in deeper than intended sedation events (Wald difference, −1.38%; 95% CI, −20.21% to 17.49%; P = 0.887). CONCLUSIONS: Use of advanced monitoring parameters during planned moderate sedation was associated with fewer alarm events, patients experiencing desaturation, and patients experiencing respiratory depression alarm events. This pilot study suggests that further study into the safety and outcome impacts of advanced monitoring during procedure-related sedation is warranted. Lippincott Williams & Wilkins 2016-04 2016-02-01 /pmc/articles/PMC4791313/ /pubmed/26836134 http://dx.doi.org/10.1213/ANE.0000000000001160 Text en Copyright © 2016 International Anesthesia Research Society This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.
spellingShingle 8
Applegate, Richard L.
Lenart, John
Malkin, Mathew
Meineke, Minhthy N.
Qoshlli, Silvana
Neumann, Monica
Jacobson, J. Paul
Kruger, Alison
Ching, Jeffrey
Hassanian, Mohammad
Um, Michael
Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title_full Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title_fullStr Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title_full_unstemmed Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title_short Advanced Monitoring Is Associated with Fewer Alarm Events During Planned Moderate Procedure-Related Sedation: A 2-Part Pilot Trial
title_sort advanced monitoring is associated with fewer alarm events during planned moderate procedure-related sedation: a 2-part pilot trial
topic 8
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791313/
https://www.ncbi.nlm.nih.gov/pubmed/26836134
http://dx.doi.org/10.1213/ANE.0000000000001160
work_keys_str_mv AT applegaterichardl advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT lenartjohn advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT malkinmathew advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT meinekeminhthyn advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT qoshllisilvana advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT neumannmonica advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT jacobsonjpaul advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT krugeralison advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT chingjeffrey advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT hassanianmohammad advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial
AT ummichael advancedmonitoringisassociatedwithfeweralarmeventsduringplannedmoderateprocedurerelatedsedationa2partpilottrial