Cargando…

Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters

Intensity non-uniformity (INU) in magnetic resonance (MR) imaging is a major issue when conducting analyses of brain structural properties. An inaccurate INU correction may result in qualitative and quantitative misinterpretations. Several INU correction methods exist, whose performance largely depe...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganzetti, Marco, Wenderoth, Nicole, Mantini, Dante
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791378/
https://www.ncbi.nlm.nih.gov/pubmed/27014050
http://dx.doi.org/10.3389/fninf.2016.00010
_version_ 1782421074750734336
author Ganzetti, Marco
Wenderoth, Nicole
Mantini, Dante
author_facet Ganzetti, Marco
Wenderoth, Nicole
Mantini, Dante
author_sort Ganzetti, Marco
collection PubMed
description Intensity non-uniformity (INU) in magnetic resonance (MR) imaging is a major issue when conducting analyses of brain structural properties. An inaccurate INU correction may result in qualitative and quantitative misinterpretations. Several INU correction methods exist, whose performance largely depend on the specific parameter settings that need to be chosen by the user. Here we addressed the question of how to select the best input parameters for a specific INU correction algorithm. Our investigation was based on the INU correction algorithm implemented in SPM, but this can be in principle extended to any other algorithm requiring the selection of input parameters. We conducted a comprehensive comparison of indirect metrics for the assessment of INU correction performance, namely the coefficient of variation of white matter (CV(WM)), the coefficient of variation of gray matter (CV(GM)), and the coefficient of joint variation between white matter and gray matter (CJV). Using simulated MR data, we observed the CJV to be more accurate than CV(WM) and CV(GM), provided that the noise level in the INU-corrected image was controlled by means of spatial smoothing. Based on the CJV, we developed a data-driven approach for selecting INU correction parameters, which could effectively work on actual MR images. To this end, we implemented an enhanced procedure for the definition of white and gray matter masks, based on which the CJV was calculated. Our approach was validated using actual T1-weighted images collected with 1.5 T, 3 T, and 7 T MR scanners. We found that our procedure can reliably assist the selection of valid INU correction algorithm parameters, thereby contributing to an enhanced inhomogeneity correction in MR images.
format Online
Article
Text
id pubmed-4791378
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-47913782016-03-24 Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters Ganzetti, Marco Wenderoth, Nicole Mantini, Dante Front Neuroinform Neuroscience Intensity non-uniformity (INU) in magnetic resonance (MR) imaging is a major issue when conducting analyses of brain structural properties. An inaccurate INU correction may result in qualitative and quantitative misinterpretations. Several INU correction methods exist, whose performance largely depend on the specific parameter settings that need to be chosen by the user. Here we addressed the question of how to select the best input parameters for a specific INU correction algorithm. Our investigation was based on the INU correction algorithm implemented in SPM, but this can be in principle extended to any other algorithm requiring the selection of input parameters. We conducted a comprehensive comparison of indirect metrics for the assessment of INU correction performance, namely the coefficient of variation of white matter (CV(WM)), the coefficient of variation of gray matter (CV(GM)), and the coefficient of joint variation between white matter and gray matter (CJV). Using simulated MR data, we observed the CJV to be more accurate than CV(WM) and CV(GM), provided that the noise level in the INU-corrected image was controlled by means of spatial smoothing. Based on the CJV, we developed a data-driven approach for selecting INU correction parameters, which could effectively work on actual MR images. To this end, we implemented an enhanced procedure for the definition of white and gray matter masks, based on which the CJV was calculated. Our approach was validated using actual T1-weighted images collected with 1.5 T, 3 T, and 7 T MR scanners. We found that our procedure can reliably assist the selection of valid INU correction algorithm parameters, thereby contributing to an enhanced inhomogeneity correction in MR images. Frontiers Media S.A. 2016-03-15 /pmc/articles/PMC4791378/ /pubmed/27014050 http://dx.doi.org/10.3389/fninf.2016.00010 Text en Copyright © 2016 Ganzetti, Wenderoth and Mantini. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Ganzetti, Marco
Wenderoth, Nicole
Mantini, Dante
Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title_full Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title_fullStr Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title_full_unstemmed Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title_short Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
title_sort intensity inhomogeneity correction of structural mr images: a data-driven approach to define input algorithm parameters
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791378/
https://www.ncbi.nlm.nih.gov/pubmed/27014050
http://dx.doi.org/10.3389/fninf.2016.00010
work_keys_str_mv AT ganzettimarco intensityinhomogeneitycorrectionofstructuralmrimagesadatadrivenapproachtodefineinputalgorithmparameters
AT wenderothnicole intensityinhomogeneitycorrectionofstructuralmrimagesadatadrivenapproachtodefineinputalgorithmparameters
AT mantinidante intensityinhomogeneitycorrectionofstructuralmrimagesadatadrivenapproachtodefineinputalgorithmparameters