The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs
BACKGROUND: There is a need for accurate and field-applicable instruments for the evaluation of the quality of anti-malarial drugs. The aim of this study was to determine the diagnostic accuracy of the NanoRam(®), a handheld Raman spectrometer (RS), to identify anti-malarial drugs. METHODS: In total...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791808/ https://www.ncbi.nlm.nih.gov/pubmed/26975570 http://dx.doi.org/10.1186/s12936-016-1212-y |
_version_ | 1782421143570874368 |
---|---|
author | Visser, Benjamin J. de Vries, Sophia G. Bache, Emmanuel B. Meerveld-Gerrits, Janneke Kroon, Daniëlle Boersma, Jimmy Agnandji, Selidji T. van Vugt, Michèle Grobusch, Martin P. |
author_facet | Visser, Benjamin J. de Vries, Sophia G. Bache, Emmanuel B. Meerveld-Gerrits, Janneke Kroon, Daniëlle Boersma, Jimmy Agnandji, Selidji T. van Vugt, Michèle Grobusch, Martin P. |
author_sort | Visser, Benjamin J. |
collection | PubMed |
description | BACKGROUND: There is a need for accurate and field-applicable instruments for the evaluation of the quality of anti-malarial drugs. The aim of this study was to determine the diagnostic accuracy of the NanoRam(®), a handheld Raman spectrometer (RS), to identify anti-malarial drugs. METHODS: In total, 289 anti-malarial drugs collected in a randomized field survey in Gabon were evaluated. The samples were compared with authentic products as supplied by the official manufacturer. To determine the sensitivity and specificity of the handheld NanoRam(®) spectrometer in the identification of anti-malarial drugs, a two-gate reversed-flow design was applied. The standards for reporting of diagnostic accuracy studies (STARD) were followed. The index test was the handheld RS. The reference test standards were thin layer chromatography and high performance liquid chromatography with ultraviolet photo diode array detection. RESULTS: The sensitivity [95 % confidence interval (95 % CI)] and specificity of the RS to correctly identify an anti-malarial drug were 100 % (95 % CI 94.9–100 %) and 96 % (95 % CI 92.3–99.0 %), respectively. The RS could not differentiate between different batches of the same product or different manufacturers of the same product. Intra-observer agreement for 289 samples was 100 %. The average time to conduct the RS was 15 s per sample compared to 45 min per sample for TLC. CONCLUSION: The handheld RS holds promise as an easy-to-use, quick and field-applicable instrument for the evaluation of quality of anti-malarial drugs, potentially empowering pharmacists, drug inspectors and medical regulatory authorities. Trial registration NTR4341 (Dutch Trial Registry) ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12936-016-1212-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4791808 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-47918082016-03-16 The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs Visser, Benjamin J. de Vries, Sophia G. Bache, Emmanuel B. Meerveld-Gerrits, Janneke Kroon, Daniëlle Boersma, Jimmy Agnandji, Selidji T. van Vugt, Michèle Grobusch, Martin P. Malar J Research BACKGROUND: There is a need for accurate and field-applicable instruments for the evaluation of the quality of anti-malarial drugs. The aim of this study was to determine the diagnostic accuracy of the NanoRam(®), a handheld Raman spectrometer (RS), to identify anti-malarial drugs. METHODS: In total, 289 anti-malarial drugs collected in a randomized field survey in Gabon were evaluated. The samples were compared with authentic products as supplied by the official manufacturer. To determine the sensitivity and specificity of the handheld NanoRam(®) spectrometer in the identification of anti-malarial drugs, a two-gate reversed-flow design was applied. The standards for reporting of diagnostic accuracy studies (STARD) were followed. The index test was the handheld RS. The reference test standards were thin layer chromatography and high performance liquid chromatography with ultraviolet photo diode array detection. RESULTS: The sensitivity [95 % confidence interval (95 % CI)] and specificity of the RS to correctly identify an anti-malarial drug were 100 % (95 % CI 94.9–100 %) and 96 % (95 % CI 92.3–99.0 %), respectively. The RS could not differentiate between different batches of the same product or different manufacturers of the same product. Intra-observer agreement for 289 samples was 100 %. The average time to conduct the RS was 15 s per sample compared to 45 min per sample for TLC. CONCLUSION: The handheld RS holds promise as an easy-to-use, quick and field-applicable instrument for the evaluation of quality of anti-malarial drugs, potentially empowering pharmacists, drug inspectors and medical regulatory authorities. Trial registration NTR4341 (Dutch Trial Registry) ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12936-016-1212-y) contains supplementary material, which is available to authorized users. BioMed Central 2016-03-15 /pmc/articles/PMC4791808/ /pubmed/26975570 http://dx.doi.org/10.1186/s12936-016-1212-y Text en © Visser et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Visser, Benjamin J. de Vries, Sophia G. Bache, Emmanuel B. Meerveld-Gerrits, Janneke Kroon, Daniëlle Boersma, Jimmy Agnandji, Selidji T. van Vugt, Michèle Grobusch, Martin P. The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title | The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title_full | The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title_fullStr | The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title_full_unstemmed | The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title_short | The diagnostic accuracy of the hand-held Raman spectrometer for the identification of anti-malarial drugs |
title_sort | diagnostic accuracy of the hand-held raman spectrometer for the identification of anti-malarial drugs |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4791808/ https://www.ncbi.nlm.nih.gov/pubmed/26975570 http://dx.doi.org/10.1186/s12936-016-1212-y |
work_keys_str_mv | AT visserbenjaminj thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT devriessophiag thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT bacheemmanuelb thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT meerveldgerritsjanneke thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT kroondanielle thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT boersmajimmy thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT agnandjiselidjit thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT vanvugtmichele thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT grobuschmartinp thediagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT visserbenjaminj diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT devriessophiag diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT bacheemmanuelb diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT meerveldgerritsjanneke diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT kroondanielle diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT boersmajimmy diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT agnandjiselidjit diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT vanvugtmichele diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs AT grobuschmartinp diagnosticaccuracyofthehandheldramanspectrometerfortheidentificationofantimalarialdrugs |