Cargando…
Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation
To investigate the clinical outcome of a surgical technique with tissue preservation for a wide bone-anchored hearing implant concerning postoperative complications, skin reactions, implant loss, and implant stability. STUDY DESIGN: Consecutive, prospective case series. SETTING: Tertiary referral ce...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4792196/ https://www.ncbi.nlm.nih.gov/pubmed/26954348 http://dx.doi.org/10.1097/MAO.0000000000000990 |
_version_ | 1782421205695856640 |
---|---|
author | Mowinckel, Marius S. Møller, Martin N. Wielandt, Kirsten N. Foghsgaard, Søren |
author_facet | Mowinckel, Marius S. Møller, Martin N. Wielandt, Kirsten N. Foghsgaard, Søren |
author_sort | Mowinckel, Marius S. |
collection | PubMed |
description | To investigate the clinical outcome of a surgical technique with tissue preservation for a wide bone-anchored hearing implant concerning postoperative complications, skin reactions, implant loss, and implant stability. STUDY DESIGN: Consecutive, prospective case series. SETTING: Tertiary referral center. PATIENTS: Twenty-four adult patients with normal skin quality were enrolled. INTERVENTION(S): Implantation of bone-anchored implant was performed using a one-stage linear-incision technique with tissue preservation surgery. MAIN OUTCOME MEASURES(S): Skin and soft tissue reactions according to Holgers grading system. Pain and numbness measured according to visual analogue scale. Implant stability quotient values were recorded using resonance frequency analysis. Follow-up at 10 days, 6 weeks, 6 months, and 1 year after surgery. RESULTS: Primary implant stability was good and a significant increase in implant stability quotient occurred during the first 10 days and continued to be stable throughout the 1-year observation period. No implants were lost. Skin and soft tissue reactions were few, no reaction (Holger grade 0) was observed in 88% of the follow-up examinations and no grade 4 reactions occurred. Pain and numbness were minimal. CONCLUSION: The wide implant showed good stability initially and throughout the observation period. Skin and soft tissue reactions were rare and minor. No implants were lost. |
format | Online Article Text |
id | pubmed-4792196 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-47921962016-04-05 Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation Mowinckel, Marius S. Møller, Martin N. Wielandt, Kirsten N. Foghsgaard, Søren Otol Neurotol Prosthetic Devices To investigate the clinical outcome of a surgical technique with tissue preservation for a wide bone-anchored hearing implant concerning postoperative complications, skin reactions, implant loss, and implant stability. STUDY DESIGN: Consecutive, prospective case series. SETTING: Tertiary referral center. PATIENTS: Twenty-four adult patients with normal skin quality were enrolled. INTERVENTION(S): Implantation of bone-anchored implant was performed using a one-stage linear-incision technique with tissue preservation surgery. MAIN OUTCOME MEASURES(S): Skin and soft tissue reactions according to Holgers grading system. Pain and numbness measured according to visual analogue scale. Implant stability quotient values were recorded using resonance frequency analysis. Follow-up at 10 days, 6 weeks, 6 months, and 1 year after surgery. RESULTS: Primary implant stability was good and a significant increase in implant stability quotient occurred during the first 10 days and continued to be stable throughout the 1-year observation period. No implants were lost. Skin and soft tissue reactions were few, no reaction (Holger grade 0) was observed in 88% of the follow-up examinations and no grade 4 reactions occurred. Pain and numbness were minimal. CONCLUSION: The wide implant showed good stability initially and throughout the observation period. Skin and soft tissue reactions were rare and minor. No implants were lost. Lippincott Williams & Wilkins 2016-04 2016-03-16 /pmc/articles/PMC4792196/ /pubmed/26954348 http://dx.doi.org/10.1097/MAO.0000000000000990 Text en Copyright © 2016 Otology & Neurotology, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | Prosthetic Devices Mowinckel, Marius S. Møller, Martin N. Wielandt, Kirsten N. Foghsgaard, Søren Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title | Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title_full | Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title_fullStr | Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title_full_unstemmed | Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title_short | Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation |
title_sort | clinical outcome of a wide-diameter bone-anchored hearing implant and a surgical technique with tissue preservation |
topic | Prosthetic Devices |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4792196/ https://www.ncbi.nlm.nih.gov/pubmed/26954348 http://dx.doi.org/10.1097/MAO.0000000000000990 |
work_keys_str_mv | AT mowinckelmariuss clinicaloutcomeofawidediameterboneanchoredhearingimplantandasurgicaltechniquewithtissuepreservation AT møllermartinn clinicaloutcomeofawidediameterboneanchoredhearingimplantandasurgicaltechniquewithtissuepreservation AT wielandtkirstenn clinicaloutcomeofawidediameterboneanchoredhearingimplantandasurgicaltechniquewithtissuepreservation AT foghsgaardsøren clinicaloutcomeofawidediameterboneanchoredhearingimplantandasurgicaltechniquewithtissuepreservation |