Cargando…
Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses
BACKGROUND: Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Royan Institute
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4793174/ https://www.ncbi.nlm.nih.gov/pubmed/26985341 |
_version_ | 1782421354951213056 |
---|---|
author | Lu, Jin-Chun Yue, Ru-Qian Feng, Rui-Xiang Kong, Ling-Zhu Xu, Yuan-Cheng |
author_facet | Lu, Jin-Chun Yue, Ru-Qian Feng, Rui-Xiang Kong, Ling-Zhu Xu, Yuan-Cheng |
author_sort | Lu, Jin-Chun |
collection | PubMed |
description | BACKGROUND: Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MATERIALS AND METHODS: In this prospective study, the depths of six kinds of sperm counting chambers for both manual and computer-aided semen analyses, including Makler (n=24), Macro (n=32), Geoffrey (n=34), GoldCyto (n=20), Leja (n=20) and Cell-VU (n=20), were measured with the Filmetrics F20 Spectral Reflectance Thin-Film Measurement System, then the mean depth, the range and the coefficient of variation (CV) of each chamber, and the mean depth, relative deviation and acceptability of each kind of chamber were calculated by the closeness to the nominal value. Among the 24 Makler chambers, 5 were new and 19 were used, and the other five kinds were all new chambers. RESULTS: The depths (mean ± SD, μm) of Makler (new), Macro and Geoffrey chambers were 11.07 ± 0.41, 10.19 ± 0.48 and 10.00 ± 0.28, respectively, while those of GoldCyto, Leja and Cell-VU chambers were 23.76 ± 2.15, 20.49 ± 0.22 and 24.22 ± 2.58, respectively. The acceptability of Geoffrey chambers was the highest (94.12%), followed by Macro (65.63%), Leja (35%) and Makler (20%), while that of the other two kinds and the used Makler chamber was zero. CONCLUSION: There existed some difference between the actual depth and the corresponding nominal value for sperm counting chambers, and the overall acceptability was very low. Moreover, the abrasion caused by the long use, as of Makler chamber, for example, may result in unacceptability of the chamber. In order to ensure the accuracy and repeatability of sperm concentration results, the depth of the sperm counting chamber must be checked regularly. |
format | Online Article Text |
id | pubmed-4793174 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Royan Institute |
record_format | MEDLINE/PubMed |
spelling | pubmed-47931742016-03-16 Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses Lu, Jin-Chun Yue, Ru-Qian Feng, Rui-Xiang Kong, Ling-Zhu Xu, Yuan-Cheng Int J Fertil Steril Original Article BACKGROUND: Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MATERIALS AND METHODS: In this prospective study, the depths of six kinds of sperm counting chambers for both manual and computer-aided semen analyses, including Makler (n=24), Macro (n=32), Geoffrey (n=34), GoldCyto (n=20), Leja (n=20) and Cell-VU (n=20), were measured with the Filmetrics F20 Spectral Reflectance Thin-Film Measurement System, then the mean depth, the range and the coefficient of variation (CV) of each chamber, and the mean depth, relative deviation and acceptability of each kind of chamber were calculated by the closeness to the nominal value. Among the 24 Makler chambers, 5 were new and 19 were used, and the other five kinds were all new chambers. RESULTS: The depths (mean ± SD, μm) of Makler (new), Macro and Geoffrey chambers were 11.07 ± 0.41, 10.19 ± 0.48 and 10.00 ± 0.28, respectively, while those of GoldCyto, Leja and Cell-VU chambers were 23.76 ± 2.15, 20.49 ± 0.22 and 24.22 ± 2.58, respectively. The acceptability of Geoffrey chambers was the highest (94.12%), followed by Macro (65.63%), Leja (35%) and Makler (20%), while that of the other two kinds and the used Makler chamber was zero. CONCLUSION: There existed some difference between the actual depth and the corresponding nominal value for sperm counting chambers, and the overall acceptability was very low. Moreover, the abrasion caused by the long use, as of Makler chamber, for example, may result in unacceptability of the chamber. In order to ensure the accuracy and repeatability of sperm concentration results, the depth of the sperm counting chamber must be checked regularly. Royan Institute 2016 2015-12-23 /pmc/articles/PMC4793174/ /pubmed/26985341 Text en Any use, distribution, reproduction or abstract of this publication in any medium, with the exception of commercial purposes, is permitted provided the original work is properly cited http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lu, Jin-Chun Yue, Ru-Qian Feng, Rui-Xiang Kong, Ling-Zhu Xu, Yuan-Cheng Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses |
title | Accuracy Evaluation of The Depth of Six Kinds of Sperm
Counting Chambers for both Manual and
Computer-Aided Semen Analyses |
title_full | Accuracy Evaluation of The Depth of Six Kinds of Sperm
Counting Chambers for both Manual and
Computer-Aided Semen Analyses |
title_fullStr | Accuracy Evaluation of The Depth of Six Kinds of Sperm
Counting Chambers for both Manual and
Computer-Aided Semen Analyses |
title_full_unstemmed | Accuracy Evaluation of The Depth of Six Kinds of Sperm
Counting Chambers for both Manual and
Computer-Aided Semen Analyses |
title_short | Accuracy Evaluation of The Depth of Six Kinds of Sperm
Counting Chambers for both Manual and
Computer-Aided Semen Analyses |
title_sort | accuracy evaluation of the depth of six kinds of sperm
counting chambers for both manual and
computer-aided semen analyses |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4793174/ https://www.ncbi.nlm.nih.gov/pubmed/26985341 |
work_keys_str_mv | AT lujinchun accuracyevaluationofthedepthofsixkindsofspermcountingchambersforbothmanualandcomputeraidedsemenanalyses AT yueruqian accuracyevaluationofthedepthofsixkindsofspermcountingchambersforbothmanualandcomputeraidedsemenanalyses AT fengruixiang accuracyevaluationofthedepthofsixkindsofspermcountingchambersforbothmanualandcomputeraidedsemenanalyses AT konglingzhu accuracyevaluationofthedepthofsixkindsofspermcountingchambersforbothmanualandcomputeraidedsemenanalyses AT xuyuancheng accuracyevaluationofthedepthofsixkindsofspermcountingchambersforbothmanualandcomputeraidedsemenanalyses |