Cargando…
Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy
The “robotic-assisted liver tumor coagulation therapy” (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning ma...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794125/ https://www.ncbi.nlm.nih.gov/pubmed/26982341 http://dx.doi.org/10.1371/journal.pone.0149482 |
_version_ | 1782421436202221568 |
---|---|
author | Liu, Shaoli Xia, Zeyang Liu, Jianhua Xu, Jing Ren, He Lu, Tong Yang, Xiangdong |
author_facet | Liu, Shaoli Xia, Zeyang Liu, Jianhua Xu, Jing Ren, He Lu, Tong Yang, Xiangdong |
author_sort | Liu, Shaoli |
collection | PubMed |
description | The “robotic-assisted liver tumor coagulation therapy” (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles’ operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot’s movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle “collision-free reachable workspace” (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy, significantly reduce the surgeon’s workload, and is especially helpful for an inexperienced surgeon. The methodology should be easy to adapt in other body parts. |
format | Online Article Text |
id | pubmed-4794125 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47941252016-03-23 Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy Liu, Shaoli Xia, Zeyang Liu, Jianhua Xu, Jing Ren, He Lu, Tong Yang, Xiangdong PLoS One Research Article The “robotic-assisted liver tumor coagulation therapy” (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles’ operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot’s movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle “collision-free reachable workspace” (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy, significantly reduce the surgeon’s workload, and is especially helpful for an inexperienced surgeon. The methodology should be easy to adapt in other body parts. Public Library of Science 2016-03-16 /pmc/articles/PMC4794125/ /pubmed/26982341 http://dx.doi.org/10.1371/journal.pone.0149482 Text en © 2016 Liu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Liu, Shaoli Xia, Zeyang Liu, Jianhua Xu, Jing Ren, He Lu, Tong Yang, Xiangdong Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title | Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title_full | Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title_fullStr | Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title_full_unstemmed | Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title_short | Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy |
title_sort | automatic multiple-needle surgical planning of robotic-assisted microwave coagulation in large liver tumor therapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794125/ https://www.ncbi.nlm.nih.gov/pubmed/26982341 http://dx.doi.org/10.1371/journal.pone.0149482 |
work_keys_str_mv | AT liushaoli automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT xiazeyang automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT liujianhua automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT xujing automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT renhe automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT lutong automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy AT yangxiangdong automaticmultipleneedlesurgicalplanningofroboticassistedmicrowavecoagulationinlargelivertumortherapy |