Cargando…
Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
[Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study th...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American
Chemical
Society
2016
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794703/ https://www.ncbi.nlm.nih.gov/pubmed/26837532 http://dx.doi.org/10.1021/acs.analchem.5b04649 |
_version_ | 1782421505378877440 |
---|---|
author | Autebert, Julien Cors, Julien F. Taylor, David P. Kaigala, Govind V. |
author_facet | Autebert, Julien Cors, Julien F. Taylor, David P. Kaigala, Govind V. |
author_sort | Autebert, Julien |
collection | PubMed |
description | [Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study the interplay between diffusion, advection, and surface chemistry and present the design of a noncontact scanning microfluidic device to efficiently present reagents on surfaces. By leveraging convective flows, recirculation, and mixing of a processing liquid, this device overcomes limitations of existing biopatterning approaches, such as passive diffusion of analytes, uncontrolled wetting, and drying artifacts. We demonstrate the deposition of analytes, showing a 2- to 5-fold increase in deposition rate together with a 10-fold reduction in analyte consumption while ensuring less than 6% variation in pattern homogeneity on a standard biological substrate. In addition, we demonstrate the recirculation of a processing liquid using a microfluidic probe (MFP) in the context of a surface assay for (i) probing 12 independent areas with a single microliter of processing liquid and (ii) processing a 2 mm(2) surface to create 170 antibody spots of 50 × 100 μm(2) area using 1.6 μL of liquid. We observe high pattern quality, conservative usage of reagents, micrometer precision of localization and convection-enhanced fast deposition. Such a device and method may facilitate quantitative biological assays and spur the development of the next generation of protein microarrays. |
format | Online Article Text |
id | pubmed-4794703 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | American
Chemical
Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-47947032016-03-18 Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents Autebert, Julien Cors, Julien F. Taylor, David P. Kaigala, Govind V. Anal Chem [Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study the interplay between diffusion, advection, and surface chemistry and present the design of a noncontact scanning microfluidic device to efficiently present reagents on surfaces. By leveraging convective flows, recirculation, and mixing of a processing liquid, this device overcomes limitations of existing biopatterning approaches, such as passive diffusion of analytes, uncontrolled wetting, and drying artifacts. We demonstrate the deposition of analytes, showing a 2- to 5-fold increase in deposition rate together with a 10-fold reduction in analyte consumption while ensuring less than 6% variation in pattern homogeneity on a standard biological substrate. In addition, we demonstrate the recirculation of a processing liquid using a microfluidic probe (MFP) in the context of a surface assay for (i) probing 12 independent areas with a single microliter of processing liquid and (ii) processing a 2 mm(2) surface to create 170 antibody spots of 50 × 100 μm(2) area using 1.6 μL of liquid. We observe high pattern quality, conservative usage of reagents, micrometer precision of localization and convection-enhanced fast deposition. Such a device and method may facilitate quantitative biological assays and spur the development of the next generation of protein microarrays. American Chemical Society 2016-02-03 2016-03-15 /pmc/articles/PMC4794703/ /pubmed/26837532 http://dx.doi.org/10.1021/acs.analchem.5b04649 Text en Copyright © 2016 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes. |
spellingShingle | Autebert, Julien Cors, Julien F. Taylor, David P. Kaigala, Govind V. Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title | Convection-Enhanced Biopatterning with Recirculation
of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title_full | Convection-Enhanced Biopatterning with Recirculation
of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title_fullStr | Convection-Enhanced Biopatterning with Recirculation
of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title_full_unstemmed | Convection-Enhanced Biopatterning with Recirculation
of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title_short | Convection-Enhanced Biopatterning with Recirculation
of Hydrodynamically Confined Nanoliter Volumes of Reagents |
title_sort | convection-enhanced biopatterning with recirculation
of hydrodynamically confined nanoliter volumes of reagents |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794703/ https://www.ncbi.nlm.nih.gov/pubmed/26837532 http://dx.doi.org/10.1021/acs.analchem.5b04649 |
work_keys_str_mv | AT autebertjulien convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents AT corsjulienf convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents AT taylordavidp convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents AT kaigalagovindv convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents |