Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents

[Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study th...

Descripción completa

Detalles Bibliográficos
Autores principales: Autebert, Julien, Cors, Julien F., Taylor, David P., Kaigala, Govind V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2016
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794703/
https://www.ncbi.nlm.nih.gov/pubmed/26837532
http://dx.doi.org/10.1021/acs.analchem.5b04649
_version_ 1782421505378877440
author Autebert, Julien
Cors, Julien F.
Taylor, David P.
Kaigala, Govind V.
author_facet Autebert, Julien
Cors, Julien F.
Taylor, David P.
Kaigala, Govind V.
author_sort Autebert, Julien
collection PubMed
description [Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study the interplay between diffusion, advection, and surface chemistry and present the design of a noncontact scanning microfluidic device to efficiently present reagents on surfaces. By leveraging convective flows, recirculation, and mixing of a processing liquid, this device overcomes limitations of existing biopatterning approaches, such as passive diffusion of analytes, uncontrolled wetting, and drying artifacts. We demonstrate the deposition of analytes, showing a 2- to 5-fold increase in deposition rate together with a 10-fold reduction in analyte consumption while ensuring less than 6% variation in pattern homogeneity on a standard biological substrate. In addition, we demonstrate the recirculation of a processing liquid using a microfluidic probe (MFP) in the context of a surface assay for (i) probing 12 independent areas with a single microliter of processing liquid and (ii) processing a 2 mm(2) surface to create 170 antibody spots of 50 × 100 μm(2) area using 1.6 μL of liquid. We observe high pattern quality, conservative usage of reagents, micrometer precision of localization and convection-enhanced fast deposition. Such a device and method may facilitate quantitative biological assays and spur the development of the next generation of protein microarrays.
format Online
Article
Text
id pubmed-4794703
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-47947032016-03-18 Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents Autebert, Julien Cors, Julien F. Taylor, David P. Kaigala, Govind V. Anal Chem [Image: see text] We present a new methodology for efficient and high-quality patterning of biological reagents for surface-based biological assays. The method relies on hydrodynamically confined nanoliter volumes of reagents to interact with the substrate at the micrometer-length scale. We study the interplay between diffusion, advection, and surface chemistry and present the design of a noncontact scanning microfluidic device to efficiently present reagents on surfaces. By leveraging convective flows, recirculation, and mixing of a processing liquid, this device overcomes limitations of existing biopatterning approaches, such as passive diffusion of analytes, uncontrolled wetting, and drying artifacts. We demonstrate the deposition of analytes, showing a 2- to 5-fold increase in deposition rate together with a 10-fold reduction in analyte consumption while ensuring less than 6% variation in pattern homogeneity on a standard biological substrate. In addition, we demonstrate the recirculation of a processing liquid using a microfluidic probe (MFP) in the context of a surface assay for (i) probing 12 independent areas with a single microliter of processing liquid and (ii) processing a 2 mm(2) surface to create 170 antibody spots of 50 × 100 μm(2) area using 1.6 μL of liquid. We observe high pattern quality, conservative usage of reagents, micrometer precision of localization and convection-enhanced fast deposition. Such a device and method may facilitate quantitative biological assays and spur the development of the next generation of protein microarrays. American Chemical Society 2016-02-03 2016-03-15 /pmc/articles/PMC4794703/ /pubmed/26837532 http://dx.doi.org/10.1021/acs.analchem.5b04649 Text en Copyright © 2016 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Autebert, Julien
Cors, Julien F.
Taylor, David P.
Kaigala, Govind V.
Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title_full Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title_fullStr Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title_full_unstemmed Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title_short Convection-Enhanced Biopatterning with Recirculation of Hydrodynamically Confined Nanoliter Volumes of Reagents
title_sort convection-enhanced biopatterning with recirculation of hydrodynamically confined nanoliter volumes of reagents
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4794703/
https://www.ncbi.nlm.nih.gov/pubmed/26837532
http://dx.doi.org/10.1021/acs.analchem.5b04649
work_keys_str_mv AT autebertjulien convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents
AT corsjulienf convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents
AT taylordavidp convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents
AT kaigalagovindv convectionenhancedbiopatterningwithrecirculationofhydrodynamicallyconfinednanolitervolumesofreagents