Cargando…

Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy

OBJECTIVE: To determine whether there is a clinically relevant difference between the circulatory responses to double-lumen tube intubation (DLTI) with the GlideScope video laryngoscope versus the Macintosh direct laryngoscope. METHODS: Eighty adult patients requiring double-lumen tubes for thoracic...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Wei, Tian, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Professional Medical Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4795885/
https://www.ncbi.nlm.nih.gov/pubmed/27022341
http://dx.doi.org/10.12669/pjms.321.9044
_version_ 1782421680278208512
author Wei, Wei
Tian, Ming
author_facet Wei, Wei
Tian, Ming
author_sort Wei, Wei
collection PubMed
description OBJECTIVE: To determine whether there is a clinically relevant difference between the circulatory responses to double-lumen tube intubation (DLTI) with the GlideScope video laryngoscope versus the Macintosh direct laryngoscope. METHODS: Eighty adult patients requiring double-lumen tubes for thoracic surgery were randomly and equally allocated to either a Macintosh direct laryngoscope group (DL group, n = 40) or a Glide Scope video laryngoscope group (GS group, n = 40). DLTI was performed after airway evaluations and induction of anesthesia. Systolic blood pressure (SBP) and heart rate (HR) were recorded before induction (baseline values), immediately before intubation (post-induction values), at intubation and after intubation. Rate-pressure-product (RPP), and the areas under SBP- and HR-time curves were calculated. All data obtained by the two devices were compared. RESULTS: After laryngoscope insertion, SBP of DL and GS groups changed significantly differently (13.1% vs. 4.6%, P< 0.001), while HR changed similarly (17.2% vs. 14.6%, P = 0.074). One minute after intubation, both SBP and HR significantly increased in both groups (SBP: 11.6% vs. 11.9%; HR: 18.4% vs. 10.8%), but there were no significant differences between the two groups. RPP significantly increased in both groups after laryngoscope insertion (32.6%, P=0.001; 18.2%, P=0.002), and there was a significant difference between the two groups (P =0.001). Throughout intubation, the areas under SBP-time curves had a significant difference between the two groups (P = 0.042), while those under HR-time curves did not differ significantly (P=0.06). CONCLUSION: The intubation response was most significant upon laryngoscope insertion during the whole intubation process. The GlideScope video laryngoscope induced milder circulatory fluctuations than the Macintosh direct laryngoscope did, suggesting that DLTI using video laryngoscopy can help reduce the cardiovascular response to intubation.
format Online
Article
Text
id pubmed-4795885
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Professional Medical Publications
record_format MEDLINE/PubMed
spelling pubmed-47958852016-03-28 Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy Wei, Wei Tian, Ming Pak J Med Sci Original Article OBJECTIVE: To determine whether there is a clinically relevant difference between the circulatory responses to double-lumen tube intubation (DLTI) with the GlideScope video laryngoscope versus the Macintosh direct laryngoscope. METHODS: Eighty adult patients requiring double-lumen tubes for thoracic surgery were randomly and equally allocated to either a Macintosh direct laryngoscope group (DL group, n = 40) or a Glide Scope video laryngoscope group (GS group, n = 40). DLTI was performed after airway evaluations and induction of anesthesia. Systolic blood pressure (SBP) and heart rate (HR) were recorded before induction (baseline values), immediately before intubation (post-induction values), at intubation and after intubation. Rate-pressure-product (RPP), and the areas under SBP- and HR-time curves were calculated. All data obtained by the two devices were compared. RESULTS: After laryngoscope insertion, SBP of DL and GS groups changed significantly differently (13.1% vs. 4.6%, P< 0.001), while HR changed similarly (17.2% vs. 14.6%, P = 0.074). One minute after intubation, both SBP and HR significantly increased in both groups (SBP: 11.6% vs. 11.9%; HR: 18.4% vs. 10.8%), but there were no significant differences between the two groups. RPP significantly increased in both groups after laryngoscope insertion (32.6%, P=0.001; 18.2%, P=0.002), and there was a significant difference between the two groups (P =0.001). Throughout intubation, the areas under SBP-time curves had a significant difference between the two groups (P = 0.042), while those under HR-time curves did not differ significantly (P=0.06). CONCLUSION: The intubation response was most significant upon laryngoscope insertion during the whole intubation process. The GlideScope video laryngoscope induced milder circulatory fluctuations than the Macintosh direct laryngoscope did, suggesting that DLTI using video laryngoscopy can help reduce the cardiovascular response to intubation. Professional Medical Publications 2016 /pmc/articles/PMC4795885/ /pubmed/27022341 http://dx.doi.org/10.12669/pjms.321.9044 Text en Copyright: © Pakistan Journal of Medical Sciences http://creativecommons.org/licenses/by/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Wei, Wei
Tian, Ming
Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title_full Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title_fullStr Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title_full_unstemmed Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title_short Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
title_sort double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4795885/
https://www.ncbi.nlm.nih.gov/pubmed/27022341
http://dx.doi.org/10.12669/pjms.321.9044
work_keys_str_mv AT weiwei doublelumentubeintubationusingvideolaryngoscopycausesamildercardiovascularresponsecomparedtoclassicdirectlaryngoscopy
AT tianming doublelumentubeintubationusingvideolaryngoscopycausesamildercardiovascularresponsecomparedtoclassicdirectlaryngoscopy