Tuning-free controller to accurately regulate flow rates in a microfluidic network
We describe a control algorithm that can improve accuracy and stability of flow regulation in a microfluidic network that uses a conventional pressure pump system. The algorithm enables simultaneous and independent control of fluid flows in multiple micro-channels of a microfluidic network, but does...
Autores principales: | Heo, Young Jin, Kang, Junsu, Kim, Min Jun, Chung, Wan Kyun |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4796872/ https://www.ncbi.nlm.nih.gov/pubmed/26987587 http://dx.doi.org/10.1038/srep23273 |
Ejemplares similares
-
Real-time Image Processing for Microscopy-based Label-free Imaging Flow Cytometry in a Microfluidic Chip
por: Heo, Young Jin, et al.
Publicado: (2017) -
Accurate flow in augmented networks (AFAN): an approach to generating three-dimensional biomimetic microfluidic networks with controlled flow
por: Guo, Jiaming, et al.
Publicado: (2019) -
Effect of Temperature and Flow Rate on the Cell-Free Area in the Microfluidic Channel
por: Rodríguez-Villarreal, Angeles Ivón, et al.
Publicado: (2021) -
Tuning Properties of Polyelectrolyte-Surfactant Associates in Two-Phase Microfluidic Flows
por: Bezrukov, Artem, et al.
Publicado: (2022) -
In operando visualization of redox flow battery in membrane-free microfluidic platform
por: Park, Hyungjoo, et al.
Publicado: (2022)